Skip to main content
WireAndSun
Calculators
CEC Brand Hub

Heliene — CEC Certified Solar Equipment Catalog

Registry: California Energy Commission (CEC) Verified: 2026-11-26

Heliene holds 62 verified California Energy Commission (CEC) certifications including 62 module series (100–645W PV). Heliene carries 62 module series ranging from 100 W to 645 W STC (median 410 W vs 385 W CEC fleet median; 20.4% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

Manufacturer
Heliene
PV Module Series
62
Listed Inverters
0
Output Range
100–645W PV
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Do Heliene Solar Specifications Compare Across the CEC Catalog?

Engineering benchmark profile summarizing how Heliene photovoltaic panels and grid-support inverters compare against CEC industry medians and NEC 690 safety margins.

Homeowners evaluating Heliene hardware for residential interconnection can verify exact DC and AC test data across 62 CEC records. Heliene carries 62 module series ranging from 100 W to 645 W STC (median 410 W vs 385 W CEC fleet median; 20.4% median aperture efficiency, cell architecture Mono-c-Si, Multi-c-Si). Before finalizing string sizing, installers must adjust 25C Voc downward for regional record winter cold under NEC 690.7. No active CPSC electrical recalls match Heliene in our federal recall archive as of 2026.

Which Heliene PV Module Series Are CEC Certified? (62)

Inspect Heliene photovoltaic panel series sorted from highest STC wattage downward; near-identical wattage trims are grouped inside each series page.

Deduplicated CEC photovoltaic module series for Heliene.
Module Series STC (W) PTC (W) Voc (V) Eff (%) Variants
Heliene 156HC-645 M10 NTYP SL Bifacial 645.0 613.1 57.85 23.12 5
Heliene 156HC-630 M10 NTYP SL 630.0 598.8 55.95 22.74 3
Heliene 156HC-615 M10 NTYP SL 615.0 584.2 55.5 22.2 4
Heliene 156HC-615 M10 NTYP SL Bifacial 615.0 583.9 56.92 22.04 4
Heliene 144HC-585 M10 NTYP SL Bifacial 585.0 549.1 53.12 22.67 5
Heliene 156HC-585 M10 SL Bifacial 585.0 551.1 54.41 20.94 5
Heliene 156HC-570 M10 SL Bifacial 570.0 536.7 53.59 20.4 2
Heliene 144HC-565 M10 NTYP SL Bifacial 565.0 529.9 52.55 21.9 4
Heliene 144HC-550 M10 SL Bifacial 550.0 518.2 50.37 21.32 1
Heliene 144HC-540 M10 Bifacial 540.0 508.9 50.22 21.51 2
Heliene 144HC-535 M10 SL 535.0 500.3 49.47 21.49 4
Heliene 144HC-535 M10 SL Bifacial 535.0 503.7 49.97 20.74 5
Heliene 144HC-520 M10 Bifacial 520.0 489.6 48.73 20.72 1
Heliene 144HC-520 M10 SL 520.0 485.9 48.72 20.88 1
Heliene 144HC-520 M10 SL Bifacial 520.0 489.3 49.22 20.16 1
Heliene 132HC-500 M10 SL 500.0 471.7 46.41 21.83 1
Heliene 132HC-485 M10 SL 485.0 457.2 45.77 21.18 5
Heliene 96M475 475.0 429.8 62.39 18.85 1
Heliene 132HC-470 M10 SL 470.0 442.8 45.25 20.52 1
Heliene 144HC-460 460.0 425.2 51.26 20.81 3
Heliene 144HC-460 Bifacial 460.0 429.8 51.26 20.81 2
Heliene 96M460 460.0 415.8 61.79 18.25 5
Heliene 96M445 445.0 401.8 61.19 17.66 2
Heliene 144HC-440 Bifacial 440.0 410.7 50.43 19.91 1
Heliene 108HC-435 M10 NTYP SL 435.0 411.1 38.5 22.31 4
Heliene 108HC-435 M10 NTYP SL Bifacial 435.0 411.1 39.69 22.31 5
Heliene 96P435 435.0 390.1 61.73 17.26 4
Heliene 108HC-420 M10 NTYP SL Bifacial 420.0 396.6 39.17 21.54 2
Heliene 96P420 420.0 376.2 61.52 16.67 2
Heliene 108HC-415 M10 NTYP SL 415.0 391.7 38.02 21.28 1
Heliene 72M-410 G1 410.0 379.7 50.2 21.35 3
Heliene 96M410 410.0 366.3 60.25 15.93 5
Heliene 108HC-405 M10 SL 405.0 381.5 37.74 21.54 3
Heliene 72M-405 G1 Bifacial 405.0 374.4 49.9 21.09 2
Heliene 108HC-395 M10 SL 395.0 371.8 37.38 21.01 2
Heliene 72M-395 G1 395.0 365.4 49.26 20.57 1
Heliene 72M-395 G1 Bifacial 395.0 364.9 49.26 20.57 2
Heliene 96M395 395.0 352.5 59.5 15.35 2
Heliene 72M-385 385.0 355.6 48.62 19.54 4
Heliene 120HC-380 380.0 356.7 41.6 20.77 2
Heliene 72M-380 Bifacial 380.0 348.6 50.51 20.43 3
Heliene 120HC-370 370.0 347.1 41.22 20.22 2
Heliene 72M-370 Bifacial 370.0 339.2 47.19 19.89 1
Heliene 66M-360 HJT 360.0 338.2 48.62 20.69 1
Heliene 72M360 360.0 326.5 48.1 18.93 5
Heliene 72M335 335.0 298.1 46.64 18.23 5
Heliene 60M-325 325.0 296.5 40.67 19.68 1
Heliene 72P-325 325.0 290.3 46.11 16.75 1
Heliene 60M-315 315.0 287.0 40.01 19.07 4
Heliene 72M310 310.0 274.1 45.4 15.88 5
Heliene 72P310 310.0 276.2 45.66 16.87 5
Heliene 60M305 305.0 273.9 39.49 16.02 1
Heliene 72M290 290.0 260.2 44.65 14.85 4
Heliene 60M285 285.0 258.1 39.38 18.36 5
Heliene 72P285 285.0 253.2 44.79 15.51 3
Heliene 72P265 265.0 234.1 42.85 13.57 3
Heliene 60M260 260.0 234.2 37.73 15.63 5
Heliene 60P255 255.0 227.9 39.9 15.54 3
Heliene 60M240 240.0 216.3 36.8 14.43 4
Heliene 60P240 240.0 214.1 37.55 14.62 4
Heliene 60P220 220.0 194.8 36.6 13.23 2
Heliene 20M-100GH 100.0 85.2 13.3 6.17 1
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene Solar Hardware?

Evaluate Heliene CEC certifications (100–645W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

  • Heliene certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
  • Winter temperature swings: high-efficiency silicon cells gain open-circuit voltage below freezing; oversized DC strings can void inverter DC ceilings if NEC 690.7 is skipped.

Heliene Module + Third-Party Inverter

Pair Heliene modules (100–645W PV) with microinverters or string inverters rated above local cold-weather Voc.

Cold-Weather String Sizing (NEC 690.7)

Calculate winter record-low string Voc using CEC beta_Voc coefficients before approving final roof array layout.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Key verification checks for homeowners reviewing contractor quotes featuring Heliene solar modules or inverters. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

How many Heliene solar models are verified on the CEC list?

Our CEC archive indexes 62 Heliene equipment records (62 module series and 0 inverter models) spanning 100–645W PV. Check local building department permit requirements for Heliene before finalizing component orders.

What should homeowners check before approving Heliene equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

How efficient are Heliene solar panels compared to CEC averages?

Across listed series, Heliene modules show a median aperture efficiency of 20.4% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
  4. CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.