Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 96P435 — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 96P435 is a 435.0 W STC (390.1 W PTC) Multi-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 17.26% efficiency, 61.73 V Voc at 25 C, and 68.82 V cold Voc at -10 C (8 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
390.1 W
Voc @ 25C
61.73 V
Efficiency
17.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 96P435 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 96P435 (Multi-c-Si) residential solar systems. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Homeowners evaluating Heliene 96P435 need 14 panels for 6 kW or 19 panels (515 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.328%/C) pushes open-circuit voltage to 68.82 V at 14 F and 70.84 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Heliene 96P435 Fall Across Listed CEC Models?

Comparison of Heliene 96P435 (435.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 96P435 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 96P435: 435.0 W

What Dataset Percentiles Define Heliene 96P435?

Relative ranking of Heliene 96P435 across nameplate watts, 89.7% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Heliene 96P435 Engineering BenchmarksPercentile comparison of Heliene 96P435 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention89.7%Module Efficiency17.26%

What Do the Dataset Ranks Show for Heliene 96P435?

Summary of Heliene 96P435 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,118

17.26% Aperture Efficiency

Power density 172.6 W/m2 (2.65 percentage points below 19.91% CEC median). PTC/STC ratio: 89.7% (rank #19,653).

NEC 690.7 Limit

8 Panels Max @ -10 C (600 V)

Cold Voc reaches 68.82 V at -10 C (550.6 V string) and 70.84 V at -20 C (8 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 47.9 m2 (515 sq ft) producing 7,412 W PTC; NEC 690.8 OCPD floor is 14.26 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 61.73 * (1 + (-0.328/100) * (-10 - 25)) = 68.82 V | OCPD = 1.56 * 9.14 = 14.26 A

Inputs from CEC Modules.csv for Heliene 96P435: Voc=61.73 V, beta_Voc=-0.328%/C, Isc=9.14 A, STC=435.0 W, Area=2.52 m2.

Result: 8 panels max on 600 V (550.6 V); 19 panels for 8 kW (515 sq ft).

What Are the Published CEC Specifications for Heliene 96P435?

Complete CEC test sheet for Heliene 96P435 including Isc (9.14 A), Voc (61.73 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 96P435.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 390.1 W (89.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 61.73 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.14 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 50.52 V / 8.66 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.26% (2.52 m2) Array roof footprint density
Cell Count & Technology 96 cells (Multi-c-Si) Monofacial backsheet

How Many Heliene 96P435 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 96P435.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 380 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 515 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 624 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 96P435 series guide. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Sibling CEC listings grouped into the Heliene 96P435 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 96P425 425.0 W 380.8 W 61.59 V 50.14 V 16.86%
Heliene 96P430 430.0 W 385.5 W 61.66 V 50.32 V 17.06%
Heliene 96P435 435.0 W 390.1 W 61.73 V 50.52 V 17.26%
Heliene 96P440 440.0 W 394.7 W 61.8 V 50.73 V 17.46%

How Many Heliene 96P435 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 96P435 (61.73 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=61.73V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 70.84 V 8 panels 566.7 V 14 panels
-10 C (14 F) 68.82 V 8 panels 550.6 V 14 panels
0 C (32 F) 66.79 V 8 panels 534.3 V 14 panels
25 C (77 F STC) 61.73 V 9 panels 555.6 V 16 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 96P435?

Four comparable CEC modules such as Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} (435.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
Aptos Solar Technology LLC DNA-144-MF26-435W {Wht}
Aptos Solar Technology LLC
435.0 W Tie (0 W) 49.7 V 20.71% 92.8%
CertainTeed CT435HC11-06
CertainTeed
435.0 W Tie (0 W) 49.7 V 20.71% 91.8%
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 96P435?

Evaluate Heliene 96P435 (435.0 W STC, 61.73 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 96P435 reaches 70.84 V per panel—exceeding 8 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 515 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (515 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 96P435 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 96P435 8 kW Residential Fit

Needs 19 modules (515 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 8 panels (-10 C) or 8 panels (-20 C), or compare Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 390.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 96P435 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Why is Heliene 96P435 PTC wattage (390.1 W) lower than STC (435.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 390.1 W PTC (89.7% retention) across Heliene 96P435's 2.52 m2 aperture.

Who should skip Heliene 96P435 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 Heliene 96P435 panels (515 sq ft) leave unusable roof gaps vs. Aptos Solar Technology LLC DNA-144-MF26-435W {Blk}.

What is the 1,000 V commercial string limit for Heliene 96P435?

On 1,000 V commercial inverters at -10 C (68.82 V cold Voc), Heliene 96P435 fits up to 14 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 96P435.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.