Heliene 156HC-615 M10 NTYP SL is a 615.0 W STC (584.2 W PTC) Mono-c-Si solar module ranking #1,018 of 21,677 CEC listings (top 5.1%; higher than 94.9% of peers). It delivers 22.2% efficiency, 55.5 V Voc at 25 C, and 60.18 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 615.0 W
- PTC Wattage
- 584.2 W
- Voc @ 25C
- 55.5 V
- Efficiency
- 22.2%
How Does Heliene 156HC-615 M10 NTYP SL Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 156HC-615 M10 NTYP SL (Mono-c-Si) residential solar systems.
Heliene 156HC-615 M10 NTYP SL delivers 222.0 W/m2 (2.29 percentage points above 19.91% CEC median) and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 61.52 V per unit, capping 600 V circuits at 9 panels. Compare specs directly with Hansol Technics Co Ltd HA615AE-NGEA0 (615.0 W).
Where Does Heliene 156HC-615 M10 NTYP SL Fall Across Listed CEC Models?
Comparison of Heliene 156HC-615 M10 NTYP SL (615.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define Heliene 156HC-615 M10 NTYP SL?
Relative ranking of Heliene 156HC-615 M10 NTYP SL across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for Heliene 156HC-615 M10 NTYP SL?
Summary of Heliene 156HC-615 M10 NTYP SL output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 5.1% STC Output
615.0 W STC (+230.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.2% Aperture Efficiency
Power density 222.0 W/m2 (2.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 60.18 V at -10 C (541.6 V string) and 61.52 V at -20 C (9 max).
14 Panels = 8,610 W STC
Occupies 38.8 m2 (417 sq ft) producing 8,179 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 55.5 * (1 + (-0.241/100) * (-10 - 25)) = 60.18 V | OCPD = 1.56 * 14.19 = 22.14 A
Inputs from CEC Modules.csv for Heliene 156HC-615 M10 NTYP SL: Voc=55.5 V, beta_Voc=-0.241%/C, Isc=14.19 A, STC=615.0 W, Area=2.77 m2.
Result: 9 panels max on 600 V (541.6 V); 14 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Heliene 156HC-615 M10 NTYP SL?
Complete CEC test sheet for Heliene 156HC-615 M10 NTYP SL including Isc (14.19 A), Voc (55.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 615.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 584.2 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 55.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.19 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.2 V / 13.32 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.241 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.2% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 156HC-615 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 156HC-615 M10 NTYP SL.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.15 kW | 298 sq ft | $1,539 | $2,603 |
| 8 kW Class | 14 | 8.61 kW | 417 sq ft | $2,155 | $3,644 |
| 10 kW Class | 17 | 10.46 kW | 507 sq ft | $2,618 | $4,427 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Related Heliene power steps and black/silver trims consolidated into this Heliene 156HC-615 M10 NTYP SL series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 156HC-605 M10 NTYP SL | 605.0 W | 574.5 W | 55.2 V | 45.64 V | 21.84% |
| Heliene 156HC-610 M10 NTYP SL | 610.0 W | 579.4 W | 55.35 V | 45.92 V | 22.02% |
| Heliene 156HC-615 M10 NTYP SL | 615.0 W | 584.2 W | 55.5 V | 46.2 V | 22.2% |
| Heliene 156HC-620 M10 NTYP SL | 620.0 W | 589.1 W | 55.65 V | 46.48 V | 22.38% |
How Many Heliene 156HC-615 M10 NTYP SL Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for Heliene 156HC-615 M10 NTYP SL (55.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 61.52 V | 9 panels | 553.7 V | 16 panels |
| -10 C (14 F) | 60.18 V | 9 panels | 541.6 V | 16 panels |
| 0 C (32 F) | 58.84 V | 10 panels | 588.4 V | 16 panels |
| 25 C (77 F STC) | 55.5 V | 10 panels | 555.0 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 156HC-615 M10 NTYP SL?
Four comparable CEC modules such as Hansol Technics Co Ltd HA615AE-NGEA0 (615.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA615AE-NGEA0 Hansol Technics Co Ltd |
615.0 W | Tie (0 W) | 55.4 V | 22.2% | 95.1% |
| Hansol Technics Co Ltd HA615-AE-NNEA0 Hansol Technics Co Ltd |
615.0 W | Tie (0 W) | 55.3 V | 22.2% | 95.3% |
| New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10 New East Solar Energy (Cambodia) CoLtd |
615.0 W | Tie (0 W) | 55.3 V | 22.2% | 95.3% |
| Aptos Solar Technology LLC DNA-156-BFN10-615W-DG Aptos Solar Technology LLC |
615.0 W | Tie (0 W) | 55.08 V | 21.96% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Heliene 156HC-615 M10 NTYP SL?
Evaluate Heliene 156HC-615 M10 NTYP SL (615.0 W STC, 55.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 156HC-615 M10 NTYP SL reaches 61.52 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Heliene 156HC-615 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 156HC-615 M10 NTYP SL 8 kW Residential Fit
Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,155/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA615AE-NGEA0.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 584.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 156HC-615 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
How many Heliene 156HC-615 M10 NTYP SL panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 156HC-615 M10 NTYP SL cold Voc rises from 55.5 V to 60.18 V (beta_Voc -0.241%/C), capping a 600 V string at 9 panels (541.6 V).
How much roof area does an 8 kW array of Heliene 156HC-615 M10 NTYP SL need?
An 8 kW DC system uses 14 Heliene 156HC-615 M10 NTYP SL modules (8,610 W STC / 8,179 W PTC), covering roughly 417 sq ft and saving ~$2,155/yr at 18.54 c/kWh.
How does Heliene 156HC-615 M10 NTYP SL compare against Hansol Technics Co Ltd HA615AE-NGEA0?
Heliene 156HC-615 M10 NTYP SL outputs 615.0 W STC (55.5 V Voc, rank #1,018 of 21,677), while Hansol Technics Co Ltd HA615AE-NGEA0 delivers 615.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)