Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 156HC-615 M10 NTYP SL — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 156HC-615 M10 NTYP SL is a 615.0 W STC (584.2 W PTC) Mono-c-Si solar module ranking #1,018 of 21,677 CEC listings (top 5.1%; higher than 94.9% of peers). It delivers 22.2% efficiency, 55.5 V Voc at 25 C, and 60.18 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
615.0 W
PTC Wattage
584.2 W
Voc @ 25C
55.5 V
Efficiency
22.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 156HC-615 M10 NTYP SL Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 156HC-615 M10 NTYP SL (Mono-c-Si) residential solar systems.

Heliene 156HC-615 M10 NTYP SL delivers 222.0 W/m2 (2.29 percentage points above 19.91% CEC median) and strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677), placing it as a large-format commercial and ground-mount module better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. At -4 F (-20 C), string voltage climbs to 61.52 V per unit, capping 600 V circuits at 9 panels. Compare specs directly with Hansol Technics Co Ltd HA615AE-NGEA0 (615.0 W).

Where Does Heliene 156HC-615 M10 NTYP SL Fall Across Listed CEC Models?

Comparison of Heliene 156HC-615 M10 NTYP SL (615.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 156HC-615 M10 NTYP SL (615.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 156HC-615 : 615.0 W

What Dataset Percentiles Define Heliene 156HC-615 M10 NTYP SL?

Relative ranking of Heliene 156HC-615 M10 NTYP SL across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

Heliene 156HC-615 M10 NTYP SL Engineering BenchmarksPercentile comparison of Heliene 156HC-615 M10 NTYP SL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage615.0 WPTC/STC Retention95.0%Module Efficiency22.2%

What Do the Dataset Ranks Show for Heliene 156HC-615 M10 NTYP SL?

Summary of Heliene 156HC-615 M10 NTYP SL output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,018 / 21,677

Top 5.1% STC Output

615.0 W STC (+230.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #2,649

22.2% Aperture Efficiency

Power density 222.0 W/m2 (2.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.18 V at -10 C (541.6 V string) and 61.52 V at -20 C (9 max).

8 kW Reference Array

14 Panels = 8,610 W STC

Occupies 38.8 m2 (417 sq ft) producing 8,179 W PTC; NEC 690.8 OCPD floor is 22.14 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 55.5 * (1 + (-0.241/100) * (-10 - 25)) = 60.18 V | OCPD = 1.56 * 14.19 = 22.14 A

Inputs from CEC Modules.csv for Heliene 156HC-615 M10 NTYP SL: Voc=55.5 V, beta_Voc=-0.241%/C, Isc=14.19 A, STC=615.0 W, Area=2.77 m2.

Result: 9 panels max on 600 V (541.6 V); 14 panels for 8 kW (417 sq ft).

What Are the Published CEC Specifications for Heliene 156HC-615 M10 NTYP SL?

Complete CEC test sheet for Heliene 156HC-615 M10 NTYP SL including Isc (14.19 A), Voc (55.5 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 156HC-615 M10 NTYP SL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 615.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 584.2 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 55.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.19 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.2 V / 13.32 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.2% (2.77 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 156HC-615 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 156HC-615 M10 NTYP SL.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.15 kW 298 sq ft $1,539 $2,603
8 kW Class 14 8.61 kW 417 sq ft $2,155 $3,644
10 kW Class 17 10.46 kW 507 sq ft $2,618 $4,427

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 156HC-615 M10 NTYP SL series guide.

Sibling CEC listings grouped into the Heliene 156HC-615 M10 NTYP SL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 156HC-605 M10 NTYP SL 605.0 W 574.5 W 55.2 V 45.64 V 21.84%
Heliene 156HC-610 M10 NTYP SL 610.0 W 579.4 W 55.35 V 45.92 V 22.02%
Heliene 156HC-615 M10 NTYP SL 615.0 W 584.2 W 55.5 V 46.2 V 22.2%
Heliene 156HC-620 M10 NTYP SL 620.0 W 589.1 W 55.65 V 46.48 V 22.38%

How Many Heliene 156HC-615 M10 NTYP SL Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 156HC-615 M10 NTYP SL (55.5 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=55.5V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 61.52 V 9 panels 553.7 V 16 panels
-10 C (14 F) 60.18 V 9 panels 541.6 V 16 panels
0 C (32 F) 58.84 V 10 panels 588.4 V 16 panels
25 C (77 F STC) 55.5 V 10 panels 555.0 V 18 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 156HC-615 M10 NTYP SL?

Four comparable CEC modules such as Hansol Technics Co Ltd HA615AE-NGEA0 (615.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hansol Technics Co Ltd HA615AE-NGEA0
Hansol Technics Co Ltd
615.0 W Tie (0 W) 55.4 V 22.2% 95.1%
Hansol Technics Co Ltd HA615-AE-NNEA0
Hansol Technics Co Ltd
615.0 W Tie (0 W) 55.3 V 22.2% 95.3%
New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10
New East Solar Energy (Cambodia) CoLtd
615.0 W Tie (0 W) 55.3 V 22.2% 95.3%
Aptos Solar Technology LLC DNA-156-BFN10-615W-DG
Aptos Solar Technology LLC
615.0 W Tie (0 W) 55.08 V 21.96% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 156HC-615 M10 NTYP SL?

Evaluate Heliene 156HC-615 M10 NTYP SL (615.0 W STC, 55.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 156HC-615 M10 NTYP SL reaches 61.52 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Heliene 156HC-615 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 156HC-615 M10 NTYP SL 8 kW Residential Fit

Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,155/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA615AE-NGEA0.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 584.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 156HC-615 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

How many Heliene 156HC-615 M10 NTYP SL panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 156HC-615 M10 NTYP SL cold Voc rises from 55.5 V to 60.18 V (beta_Voc -0.241%/C), capping a 600 V string at 9 panels (541.6 V).

How much roof area does an 8 kW array of Heliene 156HC-615 M10 NTYP SL need?

An 8 kW DC system uses 14 Heliene 156HC-615 M10 NTYP SL modules (8,610 W STC / 8,179 W PTC), covering roughly 417 sq ft and saving ~$2,155/yr at 18.54 c/kWh.

How does Heliene 156HC-615 M10 NTYP SL compare against Hansol Technics Co Ltd HA615AE-NGEA0?

Heliene 156HC-615 M10 NTYP SL outputs 615.0 W STC (55.5 V Voc, rank #1,018 of 21,677), while Hansol Technics Co Ltd HA615AE-NGEA0 delivers 615.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.