Hansol Technics Co Ltd HA615-AE-NNEA0 is a 615.0 W STC (586.2 W PTC) Mono-c-Si solar module ranking #1,018 of 21,677 CEC listings (top 5.1%; higher than 94.9% of peers). It delivers 22.2% efficiency, 55.3 V Voc at 25 C, and 59.69 V cold Voc at -10 C (10 panels max per 600 V string).
- STC Wattage
- 615.0 W
- PTC Wattage
- 586.2 W
- Voc @ 25C
- 55.3 V
- Efficiency
- 22.2%
How Does Hansol Technics Co Ltd HA615-AE-NNEA0 Compare Against Peer CEC Listings?
Solar engineering breakdown for Hansol Technics Co Ltd HA615-AE-NNEA0: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hansol Technics Co Ltd and peers, Hansol Technics Co Ltd HA615-AE-NNEA0 stands 205.0 W above the 410.0 W Mono-c-Si median and strong 95.3% PTC-to-STC heat retention (#237 of 21,677). Sizing 6 kW (10 panels) to 10 kW (17 panels) yields $1,539-$2,618/yr in baseline US bill offset. Higher 55.3 V open-circuit voltage caps 600 V residential strings at 10 panels at 14 F (-10 C).
Where Does Hansol Technics Co Ltd HA615-AE-NNEA0 Fall Across Listed CEC Models?
Distribution marker showing Hansol Technics Co Ltd HA615-AE-NNEA0 (615.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA615-AE-NNEA0?
Dataset percentiles tracking Hansol Technics Co Ltd HA615-AE-NNEA0 power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA615-AE-NNEA0?
Benchmark highlights for Hansol Technics Co Ltd HA615-AE-NNEA0 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 5.1% STC Output
615.0 W STC (+230.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.2% Aperture Efficiency
Power density 222.0 W/m2 (2.29 percentage points above 19.91% CEC median). PTC/STC ratio: 95.3% (rank #237).
10 Panels Max @ -10 C (600 V)
Cold Voc reaches 59.69 V at -10 C (596.9 V string) and 60.95 V at -20 C (9 max).
14 Panels = 8,610 W STC
Occupies 38.8 m2 (417 sq ft) producing 8,207 W PTC; NEC 690.8 OCPD floor is 22.09 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 55.3 * (1 + (-0.227/100) * (-10 - 25)) = 59.69 V | OCPD = 1.56 * 14.16 = 22.09 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA615-AE-NNEA0: Voc=55.3 V, beta_Voc=-0.227%/C, Isc=14.16 A, STC=615.0 W, Area=2.77 m2.
Result: 10 panels max on 600 V (596.9 V); 14 panels for 8 kW (417 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA615-AE-NNEA0?
Official CEC datasheet figures for Hansol Technics Co Ltd HA615-AE-NNEA0 (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 615.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 586.2 W (95.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 55.3 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.16 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 45.9 V / 13.4 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.227 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.2% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA615-AE-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hansol Technics Co Ltd HA615-AE-NNEA0 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.15 kW | 298 sq ft | $1,539 | $2,603 |
| 8 kW Class | 14 | 8.61 kW | 417 sq ft | $2,155 | $3,644 |
| 10 kW Class | 17 | 10.46 kW | 507 sq ft | $2,618 | $4,427 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
Consolidated Hansol Technics Co Ltd wattage variants sharing the Hansol Technics Co Ltd HA615-AE-NNEA0 mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA610-AE-NNEA0 | 610.0 W | 581.4 W | 55.1 V | 45.7 V | 22.02% |
| Hansol Technics Co Ltd HA615-AE-NNEA0 | 615.0 W | 586.2 W | 55.3 V | 45.9 V | 22.2% |
| Hansol Technics Co Ltd HA620-AE-NNEA0 | 620.0 W | 591.1 W | 55.5 V | 46.1 V | 22.38% |
How Many Hansol Technics Co Ltd HA615-AE-NNEA0 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hansol Technics Co Ltd HA615-AE-NNEA0 (59.69 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 60.95 V | 9 panels | 548.6 V | 16 panels |
| -10 C (14 F) | 59.69 V | 10 panels | 596.9 V | 16 panels |
| 0 C (32 F) | 58.44 V | 10 panels | 584.4 V | 17 panels |
| 25 C (77 F STC) | 55.3 V | 10 panels | 553.0 V | 18 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA615-AE-NNEA0?
Competing CEC solar panels closest to Hansol Technics Co Ltd HA615-AE-NNEA0 in nameplate wattage and Voc, starting with New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10 New East Solar Energy (Cambodia) CoLtd |
615.0 W | Tie (0 W) | 55.3 V | 22.2% | 95.3% |
| Heliene 156HC-615 M10 NTYP SL Heliene |
615.0 W | Tie (0 W) | 55.5 V | 22.2% | 95.0% |
| Aptos Solar Technology LLC DNA-156-BFN10-615W-DG Aptos Solar Technology LLC |
615.0 W | Tie (0 W) | 55.08 V | 21.96% | 94.9% |
| G-Star Pte Ltd GSD7S78T-615BT G-Star Pte Ltd |
615.0 W | Tie (0 W) | 56.24 V | 22.2% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA615-AE-NNEA0?
Evaluate Hansol Technics Co Ltd HA615-AE-NNEA0 (615.0 W STC, 55.3 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA615-AE-NNEA0 reaches 60.95 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 417 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA615-AE-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA615-AE-NNEA0 8 kW Residential Fit
Needs 14 modules (417 sq ft) with a 25 A string OCPD, offsetting ~$2,155/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 10 panels (-10 C) or 9 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE615-78THB-M10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 586.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA615-AE-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA615-AE-NNEA0?
Multiplying Hansol Technics Co Ltd HA615-AE-NNEA0's 14.16 A short-circuit current by 1.56 equals 22.09 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HA615-AE-NNEA0 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 59.69 V cold Voc at 14 F and handles 14.16 A Isc; string inverters cap Hansol Technics Co Ltd HA615-AE-NNEA0 at 10 panels on 600 V.
Is Hansol Technics Co Ltd HA615-AE-NNEA0 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA615-AE-NNEA0 rely on utility bill offset (~$2,155/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)