Skip to main content
WireAndSun
Calculators
CEC PV Module

Hansol Technics Co Ltd HA605ZB-GGFA0 — CEC Solar Module Specifications

Manufacturer: Hansol Technics Co Ltd Registry: CEC Verified Engineering Specification

Hansol Technics Co Ltd HA605ZB-GGFA0 is a 605.0 W STC (569.9 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 21.53% efficiency, 41.8 V Voc at 25 C, and 46.03 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
605.0 W
PTC Wattage
569.9 W
Voc @ 25C
41.8 V
Efficiency
21.53%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hansol Technics Co Ltd HA605ZB-GGFA0 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hansol Technics Co Ltd HA605ZB-GGFA0 (Mono-c-Si) residential solar systems.

Homeowners evaluating Hansol Technics Co Ltd HA605ZB-GGFA0 need 10 panels for 6 kW or 14 panels (423 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.289%/C) pushes open-circuit voltage to 46.03 V at 14 F and 47.24 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hansol Technics Co Ltd HA605ZB-GGFA0 Fall Across Listed CEC Models?

Comparison of Hansol Technics Co Ltd HA605ZB-GGFA0 (605.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hansol Technics Co Ltd HA605ZB-GGFA0 (605.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHansol Technics Co: 605.0 W

What Dataset Percentiles Define Hansol Technics Co Ltd HA605ZB-GGFA0?

Relative ranking of Hansol Technics Co Ltd HA605ZB-GGFA0 across nameplate watts, 94.2% PTC thermal ratio, and module aperture efficiency.

Hansol Technics Co Ltd HA605ZB-GGFA0 Engineering BenchmarksPercentile comparison of Hansol Technics Co Ltd HA605ZB-GGFA0 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage605.0 WPTC/STC Retention94.2%Module Efficiency21.53%

What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA605ZB-GGFA0?

Summary of Hansol Technics Co Ltd HA605ZB-GGFA0 output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.

Rank #1,214 / 21,677

Top 6.1% STC Output

605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,316

21.53% Aperture Efficiency

Power density 215.3 W/m2 (1.62 percentage points above 19.91% CEC median). PTC/STC ratio: 94.2% (rank #3,689).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 46.03 V at -10 C (598.4 V string) and 47.24 V at -20 C (12 max).

8 kW Reference Array

14 Panels = 8,470 W STC

Occupies 39.3 m2 (423 sq ft) producing 7,979 W PTC; NEC 690.8 OCPD floor is 28.75 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 41.8 * (1 + (-0.289/100) * (-10 - 25)) = 46.03 V | OCPD = 1.56 * 18.43 = 28.75 A

Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA605ZB-GGFA0: Voc=41.8 V, beta_Voc=-0.289%/C, Isc=18.43 A, STC=605.0 W, Area=2.81 m2.

Result: 13 panels max on 600 V (598.4 V); 14 panels for 8 kW (423 sq ft).

What Are the Published CEC Specifications for Hansol Technics Co Ltd HA605ZB-GGFA0?

Complete CEC test sheet for Hansol Technics Co Ltd HA605ZB-GGFA0 including Isc (18.43 A), Voc (41.8 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hansol Technics Co Ltd HA605ZB-GGFA0.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 605.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 569.9 W (94.2% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 41.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.43 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.9 V / 17.34 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.289 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.53% (2.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Hansol Technics Co Ltd HA605ZB-GGFA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hansol Technics Co Ltd HA605ZB-GGFA0.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.05 kW 302 sq ft $1,514 $2,561
8 kW Class 14 8.47 kW 423 sq ft $2,120 $3,585
10 kW Class 17 10.29 kW 514 sq ft $2,575 $4,355

Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?

Related Hansol Technics Co Ltd power steps and black/silver trims consolidated into this Hansol Technics Co Ltd HA605ZB-GGFA0 series guide.

Sibling CEC listings grouped into the Hansol Technics Co Ltd HA605ZB-GGFA0 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hansol Technics Co Ltd HA600ZB-GGFA0 600.0 W 565.1 W 41.6 V 34.7 V 21.35%
Hansol Technics Co Ltd HA605ZB-GGFA0 605.0 W 569.9 W 41.8 V 34.9 V 21.53%
Hansol Technics Co Ltd HA610ZB-GGFA0 610.0 W 574.8 W 42.0 V 35.1 V 21.71%

How Many Hansol Technics Co Ltd HA605ZB-GGFA0 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hansol Technics Co Ltd HA605ZB-GGFA0 (41.8 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=41.8V and beta_Voc=-0.289%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 47.24 V 12 panels 566.9 V 21 panels
-10 C (14 F) 46.03 V 13 panels 598.4 V 21 panels
0 C (32 F) 44.82 V 13 panels 582.7 V 22 panels
25 C (77 F STC) 41.8 V 14 panels 585.2 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA605ZB-GGFA0?

Four comparable CEC modules such as G-Star Pte Ltd GSD8J60M-605BT (605.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
G-Star Pte Ltd GSD8J60M-605BT
G-Star Pte Ltd
605.0 W Tie (0 W) 41.8 V 21.53% 94.2%
G-Star Pte Ltd GSD8J60M-605WT
G-Star Pte Ltd
605.0 W Tie (0 W) 41.8 V 21.53% 94.2%
KOSOL ENERGIE PVT LTD KE605G
KOSOL ENERGIE PVT LTD
605.0 W Tie (0 W) 41.8 V 21.53% 94.2%
CSI Solar Co Ltd CS7L-605MS-R
CSI Solar Co Ltd
605.0 W Tie (0 W) 41.5 V 21.61% 94.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA605ZB-GGFA0?

Evaluate Hansol Technics Co Ltd HA605ZB-GGFA0 (605.0 W STC, 41.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA605ZB-GGFA0 reaches 47.24 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 14 panels for an 8 kW build require 423 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA605ZB-GGFA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hansol Technics Co Ltd HA605ZB-GGFA0 8 kW Residential Fit

Needs 14 modules (423 sq ft) with a 30 A string OCPD, offsetting ~$2,120/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare G-Star Pte Ltd GSD8J60M-605BT.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 569.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hansol Technics Co Ltd HA605ZB-GGFA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hansol Technics Co Ltd HA605ZB-GGFA0 PTC wattage (569.9 W) lower than STC (605.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 569.9 W PTC (94.2% retention) across Hansol Technics Co Ltd HA605ZB-GGFA0's 2.81 m2 aperture.

Who should skip Hansol Technics Co Ltd HA605ZB-GGFA0 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 Hansol Technics Co Ltd HA605ZB-GGFA0 panels (423 sq ft) leave unusable roof gaps vs. G-Star Pte Ltd GSD8J60M-605BT.

What is the 1,000 V commercial string limit for Hansol Technics Co Ltd HA605ZB-GGFA0?

On 1,000 V commercial inverters at -10 C (46.03 V cold Voc), Hansol Technics Co Ltd HA605ZB-GGFA0 fits up to 21 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.