CSI Solar Co Ltd CS7L-605MS-R is a 605.0 W STC (569.0 W PTC) Mono-c-Si solar module ranking #1,214 of 21,677 CEC listings (top 6.1%; higher than 93.9% of peers). It delivers 21.61% efficiency, 41.5 V Voc at 25 C, and 45.36 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 605.0 W
- PTC Wattage
- 569.0 W
- Voc @ 25C
- 41.5 V
- Efficiency
- 21.61%
How Does CSI Solar Co Ltd CS7L-605MS-R Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CSI Solar Co Ltd CS7L-605MS-R (Mono-c-Si) residential solar systems.
Homeowners evaluating CSI Solar Co Ltd CS7L-605MS-R need 10 panels for 6 kW or 14 panels (422 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.266%/C) pushes open-circuit voltage to 45.36 V at 14 F and 46.47 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does CSI Solar Co Ltd CS7L-605MS-R Fall Across Listed CEC Models?
Comparison of CSI Solar Co Ltd CS7L-605MS-R (605.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define CSI Solar Co Ltd CS7L-605MS-R?
Relative ranking of CSI Solar Co Ltd CS7L-605MS-R across nameplate watts, 94.0% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS7L-605MS-R?
Summary of CSI Solar Co Ltd CS7L-605MS-R output rank, 8 kW array size (14 panels), efficiency rating, and 600 V string limit.
Top 6.1% STC Output
605.0 W STC (+220.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.61% Aperture Efficiency
Power density 216.1 W/m2 (1.70 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.36 V at -10 C (589.7 V string) and 46.47 V at -20 C (12 max).
14 Panels = 8,470 W STC
Occupies 39.2 m2 (422 sq ft) producing 7,966 W PTC; NEC 690.8 OCPD floor is 28.89 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.5 * (1 + (-0.266/100) * (-10 - 25)) = 45.36 V | OCPD = 1.56 * 18.52 = 28.89 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS7L-605MS-R: Voc=41.5 V, beta_Voc=-0.266%/C, Isc=18.52 A, STC=605.0 W, Area=2.8 m2.
Result: 13 panels max on 600 V (589.7 V); 14 panels for 8 kW (422 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS7L-605MS-R?
Complete CEC test sheet for CSI Solar Co Ltd CS7L-605MS-R including Isc (18.52 A), Voc (41.5 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 605.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 569.0 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.52 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 35.1 V / 17.25 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.266 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.61% (2.8 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS7L-605MS-R Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CSI Solar Co Ltd CS7L-605MS-R.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.05 kW | 301 sq ft | $1,514 | $2,561 |
| 8 kW Class | 14 | 8.47 kW | 422 sq ft | $2,120 | $3,585 |
| 10 kW Class | 17 | 10.29 kW | 512 sq ft | $2,575 | $4,355 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Related CSI Solar Co Ltd power steps and black/silver trims consolidated into this CSI Solar Co Ltd CS7L-605MS-R series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS7L-600MS-R | 600.0 W | 564.2 W | 41.3 V | 34.9 V | 21.43% |
| CSI Solar Co Ltd CS7L-605MS-R | 605.0 W | 569.0 W | 41.5 V | 35.1 V | 21.61% |
| CSI Solar Co Ltd CS7L-610MS-R | 610.0 W | 573.8 W | 41.7 V | 35.3 V | 21.79% |
How Many CSI Solar Co Ltd CS7L-605MS-R Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CSI Solar Co Ltd CS7L-605MS-R (41.5 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.47 V | 12 panels | 557.6 V | 21 panels |
| -10 C (14 F) | 45.36 V | 13 panels | 589.7 V | 22 panels |
| 0 C (32 F) | 44.26 V | 13 panels | 575.4 V | 22 panels |
| 25 C (77 F STC) | 41.5 V | 14 panels | 581.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS7L-605MS-R?
Four comparable CEC modules such as G-Star Pte Ltd GSD8J60M-605BT (605.0 W) for side-by-side solar quote checks. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| G-Star Pte Ltd GSD8J60M-605BT G-Star Pte Ltd |
605.0 W | Tie (0 W) | 41.8 V | 21.53% | 94.2% |
| G-Star Pte Ltd GSD8J60M-605WT G-Star Pte Ltd |
605.0 W | Tie (0 W) | 41.8 V | 21.53% | 94.2% |
| Hansol Technics Co Ltd HA605ZB-GGFA0 Hansol Technics Co Ltd |
605.0 W | Tie (0 W) | 41.8 V | 21.53% | 94.2% |
| KOSOL ENERGIE PVT LTD KE605G KOSOL ENERGIE PVT LTD |
605.0 W | Tie (0 W) | 41.8 V | 21.53% | 94.2% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS7L-605MS-R?
Evaluate CSI Solar Co Ltd CS7L-605MS-R (605.0 W STC, 41.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS7L-605MS-R reaches 46.47 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 14 panels for an 8 kW build require 422 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS7L-605MS-R carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS7L-605MS-R 8 kW Residential Fit
Needs 14 modules (422 sq ft) with a 30 A string OCPD, offsetting ~$2,120/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare G-Star Pte Ltd GSD8J60M-605BT.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 569.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS7L-605MS-R by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS7L-605MS-R PTC wattage (569.0 W) lower than STC (605.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 569.0 W PTC (94.0% retention) across CSI Solar Co Ltd CS7L-605MS-R's 2.8 m2 aperture.
Who should skip CSI Solar Co Ltd CS7L-605MS-R on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 14 CSI Solar Co Ltd CS7L-605MS-R panels (422 sq ft) leave unusable roof gaps vs. G-Star Pte Ltd GSD8J60M-605BT.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS7L-605MS-R?
On 1,000 V commercial inverters at -10 C (45.36 V cold Voc), CSI Solar Co Ltd CS7L-605MS-R fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)