Solar Inverter, Battery & Standby Generator Error Codes (64 Codes)

Coverage: 64 OEM Diagnostic Codes (6 Brands) Verified: 2026-11-26

This diagnostic index covers 64 manufacturer-documented fault and warning codes across Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall/Gateway, Generac Guardian Evolution 2.0, Kohler Residential, and SMA Sunny Boy. Every entry distinguishes zero-cover homeowner observations from licensed electrician troubleshooting under NFPA 70 NEC safety clearances. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.

OEM Fault Codes
64
Supported Brands
6 OEM Platforms
Homeowner Safety
Zero Live-Cover Removal
Verification Scope
Published OEM Manuals
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

Which Solar Inverter, Battery, and Generator Error Codes Are Covered? (64)

Search verified OEM fault and trip messages across Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, and SMA Sunny Boy.

64 diagnostic codes indexed

Verified manufacturer diagnostic fault codes and homeowner-safe first checks.
Brand & System Fault Code Meaning & Trigger NEC / UL Scope
Enphase
Enphase IQ7 / IQ8 Microinverters
AC-V-OOR AC Voltage Out of Range IEEE 1547 / NEC 705.12
Enphase
Enphase IQ7 / IQ8 Microinverters
AC-F-OOR AC Frequency Out of Range IEEE 1547 / UL 1741 SB
Enphase
Enphase IQ7 / IQ8 Microinverters
GRID-INSTAB Grid Instability / Grid Gone IEEE 1547 / NEC 250.24
Enphase
Enphase IQ7 / IQ8 Microinverters
DC-RES-LOW DC Resistance Low — Power Off NEC 690.41 / 690.43
Enphase
Enphase IQ7 / IQ8 Microinverters
PLC-NO-REP Microinverter Not Reporting (PLC Signal Loss) NEC 110.3(B) / 690.12
Enphase
Enphase IQ7 / IQ8 Microinverters
PEL-ZERO-EXP Power Export Limit (Zero Export) Active NEC 705.13 / Art. 130
Enphase
Enphase IQ System Controller / Battery
MID-ISLAND Microgrid Interconnect Device (MID) Islanding Fault NEC 706 / 705.40
Enphase
Enphase IQ Battery 5P / 10T
BAT-SOC-FLOOR IQ Battery Critical Reserve Shutdown NEC 706 / Art. 120
Enphase
Enphase IQ7 / IQ8 Microinverters
RSD-INIT Rapid Shutdown Initiated NEC 690.12
Enphase
Enphase IQ7 / IQ8 Microinverters
OVERTEMP-DERATE Microinverter Thermal Overtemperature Derate NEC 690.7 / 110.3(B)
Enphase
Enphase IQ7 / IQ8 Microinverters
RELAY-TEST-FAIL Internal AC Relay Self-Test Failed UL 1741 / IEEE 1547
SolarEdge
SolarEdge HD-Wave / Energy Hub
18xB7 Error 18xB7 — Hardware / Internal Inverter Fault UL 1741 / NEC 110.3(B)
SolarEdge
SolarEdge HD-Wave / Energy Hub
3x6E Error 3x6E — DC Isolation Fault (Low Riso) NEC 690.41 / 690.43
SolarEdge
SolarEdge HD-Wave / Energy Hub
18x89 Error 18x89 — DC Arc-Fault Detected (AFCI) NEC 690.11 AFCI
SolarEdge
SolarEdge HD-Wave / Energy Hub
2x-GRID-V Error 2x — AC Grid Over/Undervoltage IEEE 1547 / NEC 210.19
SolarEdge
SolarEdge HD-Wave / Energy Hub
8x-GRID-F Error 8x — AC Grid Frequency Out of Bounds IEEE 1547 / UL 1741
SolarEdge
SolarEdge HD-Wave / Energy Hub
18xBA Error 18xBA — SafeDC Active (1V per Optimizer) NEC 690.12
SolarEdge
SolarEdge HD-Wave / Energy Hub
18xBC Error 18xBC — Internal Overtemperature Derate NEC 110.3(B)
SolarEdge
SolarEdge HD-Wave / Energy Hub
3x50 Error 3x50 — Cooling Fan Speed / Stalled Fan NEC 110.3(B)
SolarEdge
SolarEdge HD-Wave / Energy Hub
1x-NO-GRID Error 1x — No AC Grid Voltage Detected NEC 705.12 / 690.13
SolarEdge
SolarEdge HD-Wave / Energy Hub
18x84 Error 18x84 — RS485 Energy Meter Comm Loss NEC 705.13
SolarEdge
SolarEdge Energy Hub / Storedge
18xC3 Error 18xC3 — Battery BMS Communication Timeout NEC 706 / UL 9540
Tesla
Tesla Powerwall 2 / 3 & Gateway
PW-ISLAND Grid Outage — Off-Grid Backup Active NEC 706 / IEEE 1547
Tesla
Tesla Backup Gateway 2 / 3
GW-RELAY Gateway Grid Contactor / Relay Fault NEC 230.85 / 706
Tesla
Tesla Powerwall 2 / 3
PW-FREQ-CURTAIL Over-Frequency Solar Curtailment (Off-Grid) UL 1741 SA / IEEE 1547
Tesla
Tesla Powerwall 2 / 3
PW-STORM-WATCH Storm Watch — Pre-Charging to 100% NEC 706 / Utility Tariff
Tesla
Tesla Backup Gateway 2 / 3
PW-CT-REV Site / Solar CT Polarity Reversed NEC 705.13
Tesla
Tesla Powerwall 3
PW3-ISO-FAULT DC Isolation / Ground Fault Detected NEC 690.41
Tesla
Tesla Powerwall 2 / 3
PW-THERMAL Thermal Derate / High Enclosure Temperature IRC R328 / UL 9540
Tesla
Tesla Powerwall 3
PW3-AFCI Integrated PV Arc-Fault (AFCI) Trip NEC 690.11
Tesla
Tesla Powerwall 2 / 3
PW-AC-OVERVOLT AC Inverter Overvoltage Shutdown IEEE 1547 / NEC 310.16
Tesla
Tesla Powerwall 2 / 3
PW-RES-FLOOR Backup Reserve Floor Reached NEC 705.12 / 705.13
Generac
Generac Guardian Evolution 2.0
1100 Code 1100 — Overcrank (Failed to Start) NFPA 37 / NFPA 54
Generac
Generac Guardian Evolution 2.0
1200 Code 1200 — Overspeed Shutdown NFPA 37 / UL 2200
Generac
Generac Guardian Evolution 2.0
1300 Code 1300 — Low Oil Pressure Shutdown NFPA 37 / OEM Spec
Generac
Generac Guardian Evolution 2.0
1400 Code 1400 — High Engine Temperature NFPA 37 / NEC 702
Generac
Generac Guardian Evolution 2.0
1505 Code 1505 — RPM Sense Loss UL 2200
Generac
Generac Guardian Evolution 2.0
1600 Code 1600 — Generator Overload NEC 702.4
Generac
Generac Guardian Evolution 2.0
1800 Code 1800 — Undervoltage NEC 702 / UL 2200
Generac
Generac Guardian Evolution 2.0
1900 Code 1900 — Overvoltage NEC 250.30 / UL 2200
Generac
Generac Guardian Evolution 2.0
1902 Code 1902 — Missing AC Sense / Blown N1/N2 Fuse NEC 702 / 230.85
Generac
Generac Guardian Evolution 2.0
2400 Code 2400 — Blown 7.5A Controller Fuse UL 2200
Generac
Generac Guardian Evolution 2.0
2800 Code 2800 — Auxiliary Shutdown Switch Open NEC 445.18
Generac
Generac Guardian Evolution 2.0
2750 Code 2750 — Inspect Battery / Low Cranking Volts NEC 702 / UL 2200
Kohler
Kohler Residential RDC2 / DC2
OC Fault OC — Overcrank Shutdown NFPA 37 / NFPA 54
Kohler
Kohler Residential RDC2 / DC2
OS Fault OS — Overspeed Shutdown UL 2200
Kohler
Kohler Residential RDC2 / DC2
LOP Fault LOP — Low Oil Pressure NFPA 37
Kohler
Kohler Residential RDC2 / DC2
HET Fault HET — High Engine Temperature NFPA 37
Kohler
Kohler Residential RDC2 / DC2
UU Fault UU — AC Undervoltage NEC 702
Kohler
Kohler Residential RDC2 / DC2
OU Fault OU — AC Overvoltage NEC 250.30 / UL 2200
Kohler
Kohler Residential RDC2 / DC2
UF Fault UF — Underfrequency (<57 Hz) NEC 702.4 / NFPA 54
Kohler
Kohler Residential RDC2 / DC2
OF Fault OF — Overfrequency (>63 Hz) UL 2200
Kohler
Kohler Residential RDC2 / DC2
AUX Fault AUX — Emergency Stop / Auxiliary Input NEC 445.18
Kohler
Kohler Residential RDC2 / DC2
BAT Alert BAT — Low Battery Voltage NEC 702
SMA
SMA Sunny Boy US-40 / US-41
EVT-101 Event 101 — Grid Voltage Upper Limit Exceeded IEEE 1547 / NEC 210.19
SMA
SMA Sunny Boy US-40 / US-41
EVT-201 Event 201 — Grid Frequency Disturbance IEEE 1547
SMA
SMA Sunny Boy US-40 / US-41
EVT-3501 Event 3501 — Insulation Resistance (Riso) Low NEC 690.41
SMA
SMA Sunny Boy US-40 / US-41
EVT-4301 Event 4301 — AFCI Arc-Fault Interruption NEC 690.11
SMA
SMA Sunny Boy US-40 / US-41
EVT-6402 Event 6402 — Temperature Power Derating NEC 110.3(B)
SMA
SMA Sunny Boy US-40 / US-41
EVT-7001 Event 7001 — Internal Self-Test / Relay Check UL 1741
SMA
SMA Sunny Boy US-40 / US-41
EVT-302 Event 302 — Grid Disconnection (Anti-Islanding) IEEE 1547 / NEC 705.12
SMA
SMA Sunny Boy US-40 / US-41
EVT-1302 Event 1302 — Waiting for Grid / DC Start NEC 690.7
SMA
SMA Sunny Boy US-40 / US-41
EVT-4101 Event 4101 — Secure Power Supply (SPS) Active NEC 705 / 210.21
SMA
SMA Sunny Boy US-40 / US-41
EVT-7701 Event 7701 — DC Overvoltage (>600V DC) NEC 690.7(A)
What to Check & Best-Fit Scenarios

When Should Homeowners Stop Troubleshooting an Inverter or Generator Code?

Know where homeowner monitoring checks end and licensed high-voltage service begins under NFPA 70E and NEC. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

  • DC solar arrays stay energized up to 600 V DC whenever sunlight strikes the roof, even after turning off an AC breaker.
  • Do not remove deadfront breaker covers or inverter wiring compartments; call a state-licensed technician for megger or torque testing.

Safe App & Visual Checks

Confirm breaker handle positions, utility outage status, LED blink counts, and battery/fuel shutoffs without tools.

Licensed Dispatch

Engage certified OEM technicians when fault codes persist after a utility outage clears or indicate DC isolation/ground faults.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Fault code troubleshooting answers below rely on published OEM manufacturer service manuals and NFPA 70 National Electrical Code safety clearances.

Can homeowners reset a grid-tie solar inverter or standby generator error code safely?

Homeowners can verify AC breaker position and read monitoring app fault history, or wait out temporary grid-frequency excursions. Persistent isolation, overvoltage, or crank faults require a licensed technician.

Why do utility grid disturbances trigger solar inverter fault codes?

Under IEEE 1547 and UL 1741, residential inverters must disconnect immediately whenever utility line voltage or frequency drifts outside tight protective windows. Consult published equipment installation sheets alongside Error Codes tables before disconnecting power.

Sources

  1. OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.