This diagnostic index covers 64 manufacturer-documented fault and warning codes across Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall/Gateway, Generac Guardian Evolution 2.0, Kohler Residential, and SMA Sunny Boy. Every entry distinguishes zero-cover homeowner observations from licensed electrician troubleshooting under NFPA 70 NEC safety clearances. All figures reconcile directly against federal energy archives, state electrical licensing boards, California Energy Commission datasheets, and National Electrical Code engineering constants.
- OEM Fault Codes
- 64
- Supported Brands
- 6 OEM Platforms
- Homeowner Safety
- Zero Live-Cover Removal
- Verification Scope
- Published OEM Manuals
Which Solar Inverter, Battery, and Generator Error Codes Are Covered? (64)
Search verified OEM fault and trip messages across Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, and SMA Sunny Boy.
64 diagnostic codes indexed
| Brand & System | Fault Code | Meaning & Trigger | NEC / UL Scope |
|---|---|---|---|
| Enphase Enphase IQ7 / IQ8 Microinverters |
AC-V-OOR | AC Voltage Out of Range | IEEE 1547 / NEC 705.12 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
AC-F-OOR | AC Frequency Out of Range | IEEE 1547 / UL 1741 SB |
| Enphase Enphase IQ7 / IQ8 Microinverters |
GRID-INSTAB | Grid Instability / Grid Gone | IEEE 1547 / NEC 250.24 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
DC-RES-LOW | DC Resistance Low — Power Off | NEC 690.41 / 690.43 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
PLC-NO-REP | Microinverter Not Reporting (PLC Signal Loss) | NEC 110.3(B) / 690.12 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
PEL-ZERO-EXP | Power Export Limit (Zero Export) Active | NEC 705.13 / Art. 130 |
| Enphase Enphase IQ System Controller / Battery |
MID-ISLAND | Microgrid Interconnect Device (MID) Islanding Fault | NEC 706 / 705.40 |
| Enphase Enphase IQ Battery 5P / 10T |
BAT-SOC-FLOOR | IQ Battery Critical Reserve Shutdown | NEC 706 / Art. 120 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
RSD-INIT | Rapid Shutdown Initiated | NEC 690.12 |
| Enphase Enphase IQ7 / IQ8 Microinverters |
OVERTEMP-DERATE | Microinverter Thermal Overtemperature Derate | NEC 690.7 / 110.3(B) |
| Enphase Enphase IQ7 / IQ8 Microinverters |
RELAY-TEST-FAIL | Internal AC Relay Self-Test Failed | UL 1741 / IEEE 1547 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
18xB7 | Error 18xB7 — Hardware / Internal Inverter Fault | UL 1741 / NEC 110.3(B) |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
3x6E | Error 3x6E — DC Isolation Fault (Low Riso) | NEC 690.41 / 690.43 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
18x89 | Error 18x89 — DC Arc-Fault Detected (AFCI) | NEC 690.11 AFCI |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
2x-GRID-V | Error 2x — AC Grid Over/Undervoltage | IEEE 1547 / NEC 210.19 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
8x-GRID-F | Error 8x — AC Grid Frequency Out of Bounds | IEEE 1547 / UL 1741 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
18xBA | Error 18xBA — SafeDC Active (1V per Optimizer) | NEC 690.12 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
18xBC | Error 18xBC — Internal Overtemperature Derate | NEC 110.3(B) |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
3x50 | Error 3x50 — Cooling Fan Speed / Stalled Fan | NEC 110.3(B) |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
1x-NO-GRID | Error 1x — No AC Grid Voltage Detected | NEC 705.12 / 690.13 |
| SolarEdge SolarEdge HD-Wave / Energy Hub |
18x84 | Error 18x84 — RS485 Energy Meter Comm Loss | NEC 705.13 |
| SolarEdge SolarEdge Energy Hub / Storedge |
18xC3 | Error 18xC3 — Battery BMS Communication Timeout | NEC 706 / UL 9540 |
| Tesla Tesla Powerwall 2 / 3 & Gateway |
PW-ISLAND | Grid Outage — Off-Grid Backup Active | NEC 706 / IEEE 1547 |
| Tesla Tesla Backup Gateway 2 / 3 |
GW-RELAY | Gateway Grid Contactor / Relay Fault | NEC 230.85 / 706 |
| Tesla Tesla Powerwall 2 / 3 |
PW-FREQ-CURTAIL | Over-Frequency Solar Curtailment (Off-Grid) | UL 1741 SA / IEEE 1547 |
| Tesla Tesla Powerwall 2 / 3 |
PW-STORM-WATCH | Storm Watch — Pre-Charging to 100% | NEC 706 / Utility Tariff |
| Tesla Tesla Backup Gateway 2 / 3 |
PW-CT-REV | Site / Solar CT Polarity Reversed | NEC 705.13 |
| Tesla Tesla Powerwall 3 |
PW3-ISO-FAULT | DC Isolation / Ground Fault Detected | NEC 690.41 |
| Tesla Tesla Powerwall 2 / 3 |
PW-THERMAL | Thermal Derate / High Enclosure Temperature | IRC R328 / UL 9540 |
| Tesla Tesla Powerwall 3 |
PW3-AFCI | Integrated PV Arc-Fault (AFCI) Trip | NEC 690.11 |
| Tesla Tesla Powerwall 2 / 3 |
PW-AC-OVERVOLT | AC Inverter Overvoltage Shutdown | IEEE 1547 / NEC 310.16 |
| Tesla Tesla Powerwall 2 / 3 |
PW-RES-FLOOR | Backup Reserve Floor Reached | NEC 705.12 / 705.13 |
| Generac Generac Guardian Evolution 2.0 |
1100 | Code 1100 — Overcrank (Failed to Start) | NFPA 37 / NFPA 54 |
| Generac Generac Guardian Evolution 2.0 |
1200 | Code 1200 — Overspeed Shutdown | NFPA 37 / UL 2200 |
| Generac Generac Guardian Evolution 2.0 |
1300 | Code 1300 — Low Oil Pressure Shutdown | NFPA 37 / OEM Spec |
| Generac Generac Guardian Evolution 2.0 |
1400 | Code 1400 — High Engine Temperature | NFPA 37 / NEC 702 |
| Generac Generac Guardian Evolution 2.0 |
1505 | Code 1505 — RPM Sense Loss | UL 2200 |
| Generac Generac Guardian Evolution 2.0 |
1600 | Code 1600 — Generator Overload | NEC 702.4 |
| Generac Generac Guardian Evolution 2.0 |
1800 | Code 1800 — Undervoltage | NEC 702 / UL 2200 |
| Generac Generac Guardian Evolution 2.0 |
1900 | Code 1900 — Overvoltage | NEC 250.30 / UL 2200 |
| Generac Generac Guardian Evolution 2.0 |
1902 | Code 1902 — Missing AC Sense / Blown N1/N2 Fuse | NEC 702 / 230.85 |
| Generac Generac Guardian Evolution 2.0 |
2400 | Code 2400 — Blown 7.5A Controller Fuse | UL 2200 |
| Generac Generac Guardian Evolution 2.0 |
2800 | Code 2800 — Auxiliary Shutdown Switch Open | NEC 445.18 |
| Generac Generac Guardian Evolution 2.0 |
2750 | Code 2750 — Inspect Battery / Low Cranking Volts | NEC 702 / UL 2200 |
| Kohler Kohler Residential RDC2 / DC2 |
OC | Fault OC — Overcrank Shutdown | NFPA 37 / NFPA 54 |
| Kohler Kohler Residential RDC2 / DC2 |
OS | Fault OS — Overspeed Shutdown | UL 2200 |
| Kohler Kohler Residential RDC2 / DC2 |
LOP | Fault LOP — Low Oil Pressure | NFPA 37 |
| Kohler Kohler Residential RDC2 / DC2 |
HET | Fault HET — High Engine Temperature | NFPA 37 |
| Kohler Kohler Residential RDC2 / DC2 |
UU | Fault UU — AC Undervoltage | NEC 702 |
| Kohler Kohler Residential RDC2 / DC2 |
OU | Fault OU — AC Overvoltage | NEC 250.30 / UL 2200 |
| Kohler Kohler Residential RDC2 / DC2 |
UF | Fault UF — Underfrequency (<57 Hz) | NEC 702.4 / NFPA 54 |
| Kohler Kohler Residential RDC2 / DC2 |
OF | Fault OF — Overfrequency (>63 Hz) | UL 2200 |
| Kohler Kohler Residential RDC2 / DC2 |
AUX | Fault AUX — Emergency Stop / Auxiliary Input | NEC 445.18 |
| Kohler Kohler Residential RDC2 / DC2 |
BAT | Alert BAT — Low Battery Voltage | NEC 702 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-101 | Event 101 — Grid Voltage Upper Limit Exceeded | IEEE 1547 / NEC 210.19 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-201 | Event 201 — Grid Frequency Disturbance | IEEE 1547 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-3501 | Event 3501 — Insulation Resistance (Riso) Low | NEC 690.41 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-4301 | Event 4301 — AFCI Arc-Fault Interruption | NEC 690.11 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-6402 | Event 6402 — Temperature Power Derating | NEC 110.3(B) |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-7001 | Event 7001 — Internal Self-Test / Relay Check | UL 1741 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-302 | Event 302 — Grid Disconnection (Anti-Islanding) | IEEE 1547 / NEC 705.12 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-1302 | Event 1302 — Waiting for Grid / DC Start | NEC 690.7 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-4101 | Event 4101 — Secure Power Supply (SPS) Active | NEC 705 / 210.21 |
| SMA SMA Sunny Boy US-40 / US-41 |
EVT-7701 | Event 7701 — DC Overvoltage (>600V DC) | NEC 690.7(A) |
When Should Homeowners Stop Troubleshooting an Inverter or Generator Code?
Know where homeowner monitoring checks end and licensed high-voltage service begins under NFPA 70E and NEC. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
- DC solar arrays stay energized up to 600 V DC whenever sunlight strikes the roof, even after turning off an AC breaker.
- Do not remove deadfront breaker covers or inverter wiring compartments; call a state-licensed technician for megger or torque testing.
Safe App & Visual Checks
Confirm breaker handle positions, utility outage status, LED blink counts, and battery/fuel shutoffs without tools.
Licensed Dispatch
Engage certified OEM technicians when fault codes persist after a utility outage clears or indicate DC isolation/ground faults.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Fault code troubleshooting answers below rely on published OEM manufacturer service manuals and NFPA 70 National Electrical Code safety clearances.
Can homeowners reset a grid-tie solar inverter or standby generator error code safely?
Homeowners can verify AC breaker position and read monitoring app fault history, or wait out temporary grid-frequency excursions. Persistent isolation, overvoltage, or crank faults require a licensed technician.
Why do utility grid disturbances trigger solar inverter fault codes?
Under IEEE 1547 and UL 1741, residential inverters must disconnect immediately whenever utility line voltage or frequency drifts outside tight protective windows. Consult published equipment installation sheets alongside Error Codes tables before disconnecting power.
Sources
- OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)