SMA Error Code EVT-4101 — Event 4101 — Secure Power Supply (SPS) Active

Manufacturer: SMA System: SMA Sunny Boy US-40 / US-41 Code Reference: NEC 705 / 210.21 Verified: 2026-11-26

When SMA Sunny Boy US-40 / US-41 displays SMA code EVT-4101 (Event 4101 — Secure Power Supply — SPS Active), equipment controls have detected an operating fault linked to NEC 705 / 210.21. Start with safe visual verification—Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns—before scheduling a qualified technician for licensed NEC 705 / 210.21 diagnostics.

OEM Platform
SMA (SMA Sunny Boy US-40 / US-41)
Fault Code
EVT-4101
Fault Summary
Event 4101 — Secure Power Supply (SPS) Active
Code Reference
NEC 705 / 210.21
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

What Triggers SMA EVT-4101 — Event 4101 — Secure Power Supply (SPS) Active?

How SMA Sunny Boy US-40 / US-41 protection firmware detects Event 4101 — Secure Power Supply — SPS Active and isolates AC or DC power flow when logging SMA fault EVT-4101.

Daytime emergency 2,000W 120V outlet mode engaged via wall switch during a grid outage.

What Can Homeowners Safely Check vs. What Requires a Licensed Technician?

Step-by-step safety boundary separating cover-closed homeowner monitoring observations from certified NEC 705 / 210.21 electrical diagnostics and torque tests.

Safe Homeowner Check (Zero Cover Removal)

Visual & App Verification

Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns.

Licensed Service Scope — NEC 705 / 210.21

Technician Diagnostic Protocol

Verify dedicated 20A SPS duplex outlet wiring per SMA US-40/41 installation instructions.

Which Related SMA Fault Codes Should You Cross-Check?

Compare SMA EVT-4101 against sibling manufacturer diagnostic codes such as EVT-101 — Event 101 — Grid Voltage Upper Limit Exceeded to rule out upstream utility or sensor issues.

What to Check & Best-Fit Scenarios

What Are the Safety Limits When Resolving SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active)?

Follow live-voltage exclusion zones and lockout rules for SMA Sunny Boy US-40 / US-41 equipment under NEC 705 / 210.21 before attempting restarts or breaker resets.

  • Do not open wireways or DC junction boxes on SMA Sunny Boy US-40 / US-41: photovoltaic strings and standby battery buses stay live even when AC breakers are switched off.
  • Repeatedly clearing SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) without resolving the underlying fault risks thermal lug damage or voided manufacturer warranty coverage.

Homeowner Observation (EVT-4101)

Stick strictly to non-invasive app and breaker status checks for SMA EVT-4101 without opening electrical covers.

Licensed Technician Scope (NEC 705 / 210.21)

Engage a certified SMA technician to perform NEC 705 / 210.21 resistance, pressure, or torque testing on SMA Sunny Boy US-40 / US-41.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Practical safety answers for SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) backed by SMA Sunny Boy US-40 / US-41 OEM manuals and NFPA 70 clearances.

Is SMA fault code EVT-4101 safe for a homeowner to inspect directly?

Homeowners should stick strictly to cover-closed checks: Keep total plugged-in SPS devices under 2,000W (16.6A @ 120V) and flip SPS switch OFF once utility power returns. Leave enclosure opening, resistance testing, and conductor replacement to a licensed technician under NEC 705 / 210.21.

What causes SMA EVT-4101 (Event 4101 — Secure Power Supply — SPS Active) on SMA Sunny Boy US-40 / US-41?

Daytime emergency 2,000W 120V outlet mode engaged via wall switch during a grid outage. Consult published equipment installation sheets alongside Sma Evt 4101 Event 4101 tables before disconnecting power.

How does a licensed electrician resolve SMA EVT-4101?

Under NEC 705 / 210.21, a qualified technician resolves SMA EVT-4101 using published OEM protocol: Verify dedicated 20A SPS duplex outlet wiring per SMA US-40/41 installation instructions.

Sources

  1. OEM Inverter & Standby Generator Diagnostic Fault Codes (Enphase IQ7/IQ8, SolarEdge HD-Wave, Tesla Powerwall, Generac Evolution 2.0, Kohler, SMA Sunny Boy) — Equipment Manufacturers (Enphase Energy, SolarEdge, Tesla Energy, Generac Power Systems, Kohler Energy, SMA Solar), 2026 Service & Installation Reference (retrieved 2026-11-25)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.