Hansol Technics Co Ltd HA635-AE-NNEA0 is a 635.0 W STC (605.7 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.92% efficiency, 56.1 V Voc at 25 C, and 60.56 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 635.0 W
- PTC Wattage
- 605.7 W
- Voc @ 25C
- 56.1 V
- Efficiency
- 22.92%
How Does Hansol Technics Co Ltd HA635-AE-NNEA0 Compare Against Peer CEC Listings?
How Hansol Technics Co Ltd Hansol Technics Co Ltd HA635-AE-NNEA0 handles rooftop heat (605.7 W PTC), 8 kW sizing, and cold winter string voltage.
Hansol Technics Co Ltd builds the Hansol Technics Co Ltd HA635-AE-NNEA0 (Mono-c-Si) as a large-format commercial and ground-mount module delivering 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). Compared against New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (635.0 W), this model holds strong 95.4% PTC-to-STC heat retention (#141 of 21,677). Higher 56.1 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), while NEC 690.8 sets a 22.4 A overcurrent floor served by a 25 A breaker.
Where Does Hansol Technics Co Ltd HA635-AE-NNEA0 Fall Across Listed CEC Models?
Where Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define Hansol Technics Co Ltd HA635-AE-NNEA0?
Percentile placement of Hansol Technics Co Ltd HA635-AE-NNEA0 across power density (229.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for Hansol Technics Co Ltd HA635-AE-NNEA0?
Four critical engineering numbers homeowners and solar installers check first when reviewing Hansol Technics Co Ltd HA635-AE-NNEA0 specifications.
Top 3.6% STC Output
635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.92% Aperture Efficiency
Power density 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 60.56 V at -10 C (545.0 V string) and 61.83 V at -20 C (9 max).
13 Panels = 8,255 W STC
Occupies 36.0 m2 (388 sq ft) producing 7,874 W PTC; NEC 690.8 OCPD floor is 22.4 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 56.1 * (1 + (-0.227/100) * (-10 - 25)) = 60.56 V | OCPD = 1.56 * 14.36 = 22.4 A
Inputs from CEC Modules.csv for Hansol Technics Co Ltd HA635-AE-NNEA0: Voc=56.1 V, beta_Voc=-0.227%/C, Isc=14.36 A, STC=635.0 W, Area=2.77 m2.
Result: 9 panels max on 600 V (545.0 V); 13 panels for 8 kW (388 sq ft).
What Are the Published CEC Specifications for Hansol Technics Co Ltd HA635-AE-NNEA0?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Hansol Technics Co Ltd HA635-AE-NNEA0.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 605.7 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 56.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.7 V / 13.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.227 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.92% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hansol Technics Co Ltd HA635-AE-NNEA0 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.35 kW | 298 sq ft | $1,589 | $2,687 |
| 8 kW Class | 13 | 8.26 kW | 388 sq ft | $2,067 | $3,496 |
| 10 kW Class | 16 | 10.16 kW | 477 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This Hansol Technics Co Ltd Series?
All closely matched Hansol Technics Co Ltd wattages and cosmetic trims sharing the Hansol Technics Co Ltd HA635-AE-NNEA0 architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA625-AE-NNEA0 | 625.0 W | 596.0 W | 55.7 V | 46.3 V | 22.56% |
| Hansol Technics Co Ltd HA630-AE-NNEA0 | 630.0 W | 600.8 W | 55.9 V | 46.5 V | 22.74% |
| Hansol Technics Co Ltd HA635-AE-NNEA0 | 635.0 W | 605.7 W | 56.1 V | 46.7 V | 22.92% |
| Hansol Technics Co Ltd HA640-AE-NNEA0 | 640.0 W | 610.6 W | 56.3 V | 46.9 V | 23.1% |
| Hansol Technics Co Ltd HA645-AE-NNEA0 | 645.0 W | 615.5 W | 56.5 V | 47.1 V | 23.29% |
How Many Hansol Technics Co Ltd HA635-AE-NNEA0 Modules Fit in a Cold-Weather String?
Maximum series module counts for Hansol Technics Co Ltd HA635-AE-NNEA0 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 61.83 V | 9 panels | 556.5 V | 16 panels |
| -10 C (14 F) | 60.56 V | 9 panels | 545.0 V | 16 panels |
| 0 C (32 F) | 59.28 V | 10 panels | 592.8 V | 16 panels |
| 25 C (77 F STC) | 56.1 V | 10 panels | 561.0 V | 17 panels |
Which Cross-Brand Solar Modules Compare Closest to Hansol Technics Co Ltd HA635-AE-NNEA0?
Alternative CEC solar modules from competing brands near Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W), including New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 New East Solar Energy (Cambodia) CoLtd |
635.0 W | Tie (0 W) | 56.1 V | 22.92% | 95.4% |
| Hanersun Energy Co Ltd HN18N-78HT635W Hanersun Energy Co Ltd |
635.0 W | Tie (0 W) | 56.2 V | 23.26% | 95.0% |
| ELITE Solar ET-N778TBH635GB ELITE Solar |
635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |
| ELITE Solar ET-N778TBH635GL ELITE Solar |
635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |
What Are the Design Limits and Best-Fit Uses for Hansol Technics Co Ltd HA635-AE-NNEA0?
Evaluate Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W STC, 56.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hansol Technics Co Ltd HA635-AE-NNEA0 reaches 61.83 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hansol Technics Co Ltd HA635-AE-NNEA0 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hansol Technics Co Ltd HA635-AE-NNEA0 8 kW Residential Fit
Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 605.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hansol Technics Co Ltd HA635-AE-NNEA0 by Hansol Technics Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hansol Technics Co Ltd HA635-AE-NNEA0?
Multiplying Hansol Technics Co Ltd HA635-AE-NNEA0's 14.36 A short-circuit current by 1.56 equals 22.4 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can Hansol Technics Co Ltd HA635-AE-NNEA0 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 60.56 V cold Voc at 14 F and handles 14.36 A Isc; string inverters cap Hansol Technics Co Ltd HA635-AE-NNEA0 at 9 panels on 600 V.
Is Hansol Technics Co Ltd HA635-AE-NNEA0 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hansol Technics Co Ltd HA635-AE-NNEA0 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)