New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 is a 635.0 W STC (605.8 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 22.92% efficiency, 56.1 V Voc at 25 C, and 60.56 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 635.0 W
- PTC Wattage
- 605.8 W
- Voc @ 25C
- 56.1 V
- Efficiency
- 22.92%
How Does New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 Compare Against Peer CEC Listings?
Engineering position of New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (635.0 W STC) vs. Hansol Technics Co Ltd HA635-AE-NNEA0 across 5,889 CEC Mono-c-Si solar modules.
Built with 78 Mono-c-Si cells, New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 pairs strong 95.4% PTC-to-STC heat retention (#141 of 21,677) with 56.1 V nominal Voc. An 8 kW residential build (8,255 W DC, 7,875 W PTC) saves ~$2,067/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Hansol Technics Co Ltd HA635-AE-NNEA0 offers a 635.0 W alternative.
Where Does New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 Fall Across Listed CEC Models?
Plots New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 at 635.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Benchmarks New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 on STC wattage, thermal PTC/STC retention, and 22.92 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 by New East Solar Energy (Cambodia) CoLtd.
Top 3.6% STC Output
635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.92% Aperture Efficiency
Power density 229.2 W/m2 (3.01 percentage points above 19.91% CEC median). PTC/STC ratio: 95.4% (rank #141).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 60.56 V at -10 C (545.0 V string) and 61.83 V at -20 C (9 max).
13 Panels = 8,255 W STC
Occupies 36.0 m2 (388 sq ft) producing 7,875 W PTC; NEC 690.8 OCPD floor is 22.4 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 56.1 * (1 + (-0.227/100) * (-10 - 25)) = 60.56 V | OCPD = 1.56 * 14.36 = 22.4 A
Inputs from CEC Modules.csv for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10: Voc=56.1 V, beta_Voc=-0.227%/C, Isc=14.36 A, STC=635.0 W, Area=2.77 m2.
Result: 9 panels max on 600 V (545.0 V); 13 panels for 8 kW (388 sq ft).
What Are the Published CEC Specifications for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Laboratory test ratings recorded for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 635.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 605.8 W (95.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 56.1 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.36 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 46.7 V / 13.6 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.227 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.92% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (388 sq ft at 8 kW), and estimated Year-1 electric bill offset for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.35 kW | 298 sq ft | $1,589 | $2,687 |
| 8 kW Class | 13 | 8.26 kW | 388 sq ft | $2,067 | $3,496 |
| 10 kW Class | 16 | 10.16 kW | 477 sq ft | $2,543 | $4,300 |
Which Sibling Wattage & Trim Variants Belong to This New East Solar Energy (Cambodia) CoLtd Series?
Sibling wattage bins and frame colors grouped with New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 under New East Solar Energy (Cambodia) CoLtd to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| New East Solar Energy (Cambodia) CoLtd NESE625-78THB-M10 | 625.0 W | 596.0 W | 55.7 V | 46.3 V | 22.56% |
| New East Solar Energy (Cambodia) CoLtd NESE630-78THB-M10 | 630.0 W | 600.9 W | 55.9 V | 46.5 V | 22.74% |
| New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 | 635.0 W | 605.8 W | 56.1 V | 46.7 V | 22.92% |
| New East Solar Energy (Cambodia) CoLtd NESE640-78THB-M10 | 640.0 W | 610.6 W | 56.3 V | 46.9 V | 23.1% |
| New East Solar Energy (Cambodia) CoLtd NESE645-78THB-M10 | 645.0 W | 615.5 W | 56.5 V | 47.1 V | 23.29% |
How Many New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (beta_Voc -0.227%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 61.83 V | 9 panels | 556.5 V | 16 panels |
| -10 C (14 F) | 60.56 V | 9 panels | 545.0 V | 16 panels |
| 0 C (32 F) | 59.28 V | 10 panels | 592.8 V | 16 panels |
| 25 C (77 F STC) | 56.1 V | 10 panels | 561.0 V | 17 panels |
Which Cross-Brand Solar Modules Compare Closest to New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Closest cross-brand CEC competitors to New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 matched near 635.0 W STC and 56.1 V Voc, led by Hansol Technics Co Ltd HA635-AE-NNEA0.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA635-AE-NNEA0 Hansol Technics Co Ltd |
635.0 W | Tie (0 W) | 56.1 V | 22.92% | 95.4% |
| Hanersun Energy Co Ltd HN18N-78HT635W Hanersun Energy Co Ltd |
635.0 W | Tie (0 W) | 56.2 V | 23.26% | 95.0% |
| ELITE Solar ET-N778TBH635GB ELITE Solar |
635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |
| ELITE Solar ET-N778TBH635GL ELITE Solar |
635.0 W | Tie (0 W) | 56.69 V | 22.68% | 95.0% |
What Are the Design Limits and Best-Fit Uses for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Evaluate New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 (635.0 W STC, 56.1 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 reaches 61.83 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 8 kW Residential Fit
Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA635-AE-NNEA0.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 605.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 by New East Solar Energy (Cambodia) CoLtd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10?
Multiplying New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10's 14.36 A short-circuit current by 1.56 equals 22.4 A minimum ampacity, requiring at least a 25 A overcurrent fuse or breaker.
Can New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 60.56 V cold Voc at 14 F and handles 14.36 A Isc; string inverters cap New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 at 9 panels on 600 V.
Is New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10 rely on utility bill offset (~$2,067/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)