Hanersun Energy Co Ltd HN18N-78HT635W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN18N-78HT635W is a 635.0 W STC (603.0 W PTC) Mono-c-Si solar module ranking #710 of 21,677 CEC listings (top 3.6%; higher than 96.4% of peers). It delivers 23.26% efficiency, 56.2 V Voc at 25 C, and 60.8 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
635.0 W
PTC Wattage
603.0 W
Voc @ 25C
56.2 V
Efficiency
23.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN18N-78HT635W Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Hanersun Energy Co Ltd HN18N-78HT635W (Mono-c-Si) residential solar systems.

Homeowners evaluating Hanersun Energy Co Ltd HN18N-78HT635W need 10 panels for 6 kW or 13 panels (382 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.234%/C) pushes open-circuit voltage to 60.8 V at 14 F and 62.12 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Hanersun Energy Co Ltd HN18N-78HT635W Fall Across Listed CEC Models?

Comparison of Hanersun Energy Co Ltd HN18N-78HT635W (635.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN18N-78HT635W (635.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 635.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN18N-78HT635W?

Relative ranking of Hanersun Energy Co Ltd HN18N-78HT635W across nameplate watts, 95.0% PTC thermal ratio, and module aperture efficiency.

Hanersun Energy Co Ltd HN18N-78HT635W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN18N-78HT635W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage635.0 WPTC/STC Retention95.0%Module Efficiency23.26%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN18N-78HT635W?

Summary of Hanersun Energy Co Ltd HN18N-78HT635W output rank, 8 kW array size (13 panels), efficiency rating, and 600 V string limit.

Rank #710 / 21,677

Top 3.6% STC Output

635.0 W STC (+250.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #770

23.26% Aperture Efficiency

Power density 232.6 W/m2 (3.35 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.8 V at -10 C (547.2 V string) and 62.12 V at -20 C (9 max).

8 kW Reference Array

13 Panels = 8,255 W STC

Occupies 35.5 m2 (382 sq ft) producing 7,839 W PTC; NEC 690.8 OCPD floor is 22.31 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 56.2 * (1 + (-0.234/100) * (-10 - 25)) = 60.8 V | OCPD = 1.56 * 14.3 = 22.31 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN18N-78HT635W: Voc=56.2 V, beta_Voc=-0.234%/C, Isc=14.3 A, STC=635.0 W, Area=2.73 m2.

Result: 9 panels max on 600 V (547.2 V); 13 panels for 8 kW (382 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN18N-78HT635W?

Complete CEC test sheet for Hanersun Energy Co Ltd HN18N-78HT635W including Isc (14.3 A), Voc (56.2 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN18N-78HT635W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 635.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 603.0 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 56.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.3 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 46.98 V / 13.52 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.234 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.26% (2.73 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN18N-78HT635W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Hanersun Energy Co Ltd HN18N-78HT635W.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.35 kW 294 sq ft $1,589 $2,687
8 kW Class 13 8.26 kW 382 sq ft $2,067 $3,496
10 kW Class 16 10.16 kW 470 sq ft $2,543 $4,300

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Related Hanersun Energy Co Ltd power steps and black/silver trims consolidated into this Hanersun Energy Co Ltd HN18N-78HT635W series guide.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN18N-78HT635W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN18N-78HT625W 625.0 W 593.3 W 55.8 V 46.58 V 22.89%
Hanersun Energy Co Ltd HN18N-78HT630W 630.0 W 598.1 W 56.0 V 46.78 V 23.08%
Hanersun Energy Co Ltd HN18N-78HT635W 635.0 W 603.0 W 56.2 V 46.98 V 23.26%
Hanersun Energy Co Ltd HN18N-78HT640W 640.0 W 607.9 W 56.4 V 47.18 V 23.44%
Hanersun Energy Co Ltd HN18N-78HT645W 645.0 W 612.7 W 56.6 V 47.38 V 23.63%

How Many Hanersun Energy Co Ltd HN18N-78HT635W Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Hanersun Energy Co Ltd HN18N-78HT635W (56.2 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=56.2V and beta_Voc=-0.234%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 62.12 V 9 panels 559.1 V 16 panels
-10 C (14 F) 60.8 V 9 panels 547.2 V 16 panels
0 C (32 F) 59.49 V 10 panels 594.9 V 16 panels
25 C (77 F STC) 56.2 V 10 panels 562.0 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN18N-78HT635W?

Four comparable CEC modules such as Hansol Technics Co Ltd HA635-AE-NNEA0 (635.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hansol Technics Co Ltd HA635-AE-NNEA0
Hansol Technics Co Ltd
635.0 W Tie (0 W) 56.1 V 22.92% 95.4%
New East Solar Energy (Cambodia) CoLtd NESE635-78THB-M10
New East Solar Energy (Cambodia) CoLtd
635.0 W Tie (0 W) 56.1 V 22.92% 95.4%
ELITE Solar ET-N778TBH635GB
ELITE Solar
635.0 W Tie (0 W) 56.69 V 22.68% 95.0%
ELITE Solar ET-N778TBH635GL
ELITE Solar
635.0 W Tie (0 W) 56.69 V 22.68% 95.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN18N-78HT635W?

Evaluate Hanersun Energy Co Ltd HN18N-78HT635W (635.0 W STC, 56.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN18N-78HT635W reaches 62.12 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 382 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN18N-78HT635W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN18N-78HT635W 8 kW Residential Fit

Needs 13 modules (382 sq ft) with a 25 A string OCPD, offsetting ~$2,067/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA635-AE-NNEA0.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 603.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN18N-78HT635W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Hanersun Energy Co Ltd HN18N-78HT635W PTC wattage (603.0 W) lower than STC (635.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 603.0 W PTC (95.0% retention) across Hanersun Energy Co Ltd HN18N-78HT635W's 2.73 m2 aperture.

Who should skip Hanersun Energy Co Ltd HN18N-78HT635W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 13 Hanersun Energy Co Ltd HN18N-78HT635W panels (382 sq ft) leave unusable roof gaps vs. Hansol Technics Co Ltd HA635-AE-NNEA0.

What is the 1,000 V commercial string limit for Hanersun Energy Co Ltd HN18N-78HT635W?

On 1,000 V commercial inverters at -10 C (60.8 V cold Voc), Hanersun Energy Co Ltd HN18N-78HT635W fits up to 16 panels per series string.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.