Hanersun Energy Co Ltd HN21N-66HT670W is a 670.0 W STC (636.8 W PTC) Mono-c-Si solar module ranking #340 of 21,677 CEC listings (top 1.7%; higher than 98.3% of peers). It delivers 22.11% efficiency, 47.0 V Voc at 25 C, and 51.67 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 670.0 W
- PTC Wattage
- 636.8 W
- Voc @ 25C
- 47.0 V
- Efficiency
- 22.11%
How Does Hanersun Energy Co Ltd HN21N-66HT670W Compare Against Peer CEC Listings?
Engineering position of Hanersun Energy Co Ltd HN21N-66HT670W (670.0 W STC) vs. Chint New Energy Technology Co Ltd CHSM66N-HC-665 across 5,889 CEC Mono-c-Si solar modules.
Ranking #340 across 21,677 CEC solar panels (top 1.7%; higher than 98.3% of peers), Hanersun Energy Co Ltd HN21N-66HT670W operates as a large-format commercial and ground-mount module sitting 260.0 W above the 410.0 W Mono-c-Si median. Mid-range 47.0 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F. With strong 95.0% PTC-to-STC heat retention (#1,106 of 21,677), 12 panels occupy 391 sq ft and offset roughly $2,012/yr at average US rates (or $3,403/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Hanersun Energy Co Ltd HN21N-66HT670W Fall Across Listed CEC Models?
Plots Hanersun Energy Co Ltd HN21N-66HT670W at 670.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Hanersun Energy Co Ltd HN21N-66HT670W?
Benchmarks Hanersun Energy Co Ltd HN21N-66HT670W on STC wattage, thermal PTC/STC retention, and 22.11 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21N-66HT670W?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Hanersun Energy Co Ltd HN21N-66HT670W by Hanersun Energy Co Ltd.
Top 1.7% STC Output
670.0 W STC (+285.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.11% Aperture Efficiency
Power density 221.1 W/m2 (2.20 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.67 V at -10 C (568.4 V string) and 53.01 V at -20 C (11 max).
12 Panels = 8,040 W STC
Occupies 36.4 m2 (391 sq ft) producing 7,642 W PTC; NEC 690.8 OCPD floor is 28.24 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.0 * (1 + (-0.284/100) * (-10 - 25)) = 51.67 V | OCPD = 1.56 * 18.1 = 28.24 A
Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21N-66HT670W: Voc=47.0 V, beta_Voc=-0.284%/C, Isc=18.1 A, STC=670.0 W, Area=3.03 m2.
Result: 11 panels max on 600 V (568.4 V); 12 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21N-66HT670W?
Laboratory test ratings recorded for Hanersun Energy Co Ltd HN21N-66HT670W (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 670.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 636.8 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 39.2 V / 17.1 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.11% (3.03 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanersun Energy Co Ltd HN21N-66HT670W Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (391 sq ft at 8 kW), and estimated Year-1 electric bill offset for Hanersun Energy Co Ltd HN21N-66HT670W.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.03 kW | 294 sq ft | $1,509 | $2,552 |
| 8 kW Class | 12 | 8.04 kW | 391 sq ft | $2,012 | $3,403 |
| 10 kW Class | 15 | 10.05 kW | 489 sq ft | $2,515 | $4,253 |
How Many Hanersun Energy Co Ltd HN21N-66HT670W Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Hanersun Energy Co Ltd HN21N-66HT670W (beta_Voc -0.284%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.01 V | 11 panels | 583.1 V | 18 panels |
| -10 C (14 F) | 51.67 V | 11 panels | 568.4 V | 19 panels |
| 0 C (32 F) | 50.34 V | 11 panels | 553.7 V | 19 panels |
| 25 C (77 F STC) | 47.0 V | 12 panels | 564.0 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21N-66HT670W?
Closest cross-brand CEC competitors to Hanersun Energy Co Ltd HN21N-66HT670W matched near 670.0 W STC and 47.0 V Voc, led by Chint New Energy Technology Co Ltd CHSM66N-HC-665.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chint New Energy Technology Co Ltd CHSM66N-HC-665 Chint New Energy Technology Co Ltd |
665.0 W | -5.0 W | 46.76 V | 21.38% | 94.3% |
| G-Star Pte Ltd GSD8J66M-675BT G-Star Pte Ltd |
675.0 W | +5.0 W | 46.4 V | 21.92% | 94.2% |
| G-Star Pte Ltd GSD8J66M-675WT G-Star Pte Ltd |
675.0 W | +5.0 W | 46.4 V | 21.92% | 94.2% |
| KOSOL ENERGIE PVT LTD KE675G KOSOL ENERGIE PVT LTD |
675.0 W | +5.0 W | 46.4 V | 21.92% | 94.3% |
What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21N-66HT670W?
Evaluate Hanersun Energy Co Ltd HN21N-66HT670W (670.0 W STC, 47.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21N-66HT670W reaches 53.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21N-66HT670W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanersun Energy Co Ltd HN21N-66HT670W 8 kW Residential Fit
Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Chint New Energy Technology Co Ltd CHSM66N-HC-665.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 636.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanersun Energy Co Ltd HN21N-66HT670W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
How many Hanersun Energy Co Ltd HN21N-66HT670W panels fit on a 600 V winter solar string?
At -10 C (14 F), Hanersun Energy Co Ltd HN21N-66HT670W cold Voc rises from 47.0 V to 51.67 V (beta_Voc -0.284%/C), capping a 600 V string at 11 panels (568.4 V).
How much roof area does an 8 kW array of Hanersun Energy Co Ltd HN21N-66HT670W need?
An 8 kW DC system uses 12 Hanersun Energy Co Ltd HN21N-66HT670W modules (8,040 W STC / 7,642 W PTC), covering roughly 391 sq ft and saving ~$2,012/yr at 18.54 c/kWh.
How does Hanersun Energy Co Ltd HN21N-66HT670W compare against Chint New Energy Technology Co Ltd CHSM66N-HC-665?
Hanersun Energy Co Ltd HN21N-66HT670W outputs 670.0 W STC (47.0 V Voc, rank #340 of 21,677), while Chint New Energy Technology Co Ltd CHSM66N-HC-665 delivers 665.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)