Skip to main content
WireAndSun
Calculators
CEC PV Module

Hanersun Energy Co Ltd HN21N-66HT705W — CEC Solar Module Specifications

Manufacturer: Hanersun Energy Co Ltd Registry: CEC Verified Engineering Specification

Hanersun Energy Co Ltd HN21N-66HT705W is a 705.0 W STC (670.8 W PTC) Mono-c-Si solar module ranking #166 of 21,677 CEC listings (top 0.9%; higher than 99.1% of peers). It delivers 23.27% efficiency, 48.4 V Voc at 25 C, and 53.21 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
705.0 W
PTC Wattage
670.8 W
Voc @ 25C
48.4 V
Efficiency
23.27%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Hanersun Energy Co Ltd HN21N-66HT705W Compare Against Peer CEC Listings?

Solar engineering breakdown for Hanersun Energy Co Ltd HN21N-66HT705W: PTC thermal retention, roof footprint, and cold Voc string bounds.

Across 5,889 Mono-c-Si listings from Hanersun Energy Co Ltd and peers, Hanersun Energy Co Ltd HN21N-66HT705W stands 295.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (9 panels) to 10 kW (15 panels) yields $1,587-$2,646/yr in baseline US bill offset. Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Hanersun Energy Co Ltd HN21N-66HT705W Fall Across Listed CEC Models?

Distribution marker showing Hanersun Energy Co Ltd HN21N-66HT705W (705.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Hanersun Energy Co Ltd HN21N-66HT705W (705.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHanersun Energy Co: 705.0 W

What Dataset Percentiles Define Hanersun Energy Co Ltd HN21N-66HT705W?

Dataset percentiles tracking Hanersun Energy Co Ltd HN21N-66HT705W power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Hanersun Energy Co Ltd HN21N-66HT705W Engineering BenchmarksPercentile comparison of Hanersun Energy Co Ltd HN21N-66HT705W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage705.0 WPTC/STC Retention95.1%Module Efficiency23.27%

What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21N-66HT705W?

Benchmark highlights for Hanersun Energy Co Ltd HN21N-66HT705W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #166 / 21,677

Top 0.9% STC Output

705.0 W STC (+320.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #759

23.27% Aperture Efficiency

Power density 232.7 W/m2 (3.36 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.21 V at -10 C (585.3 V string) and 54.59 V at -20 C (10 max).

8 kW Reference Array

12 Panels = 8,460 W STC

Occupies 36.4 m2 (391 sq ft) producing 8,050 W PTC; NEC 690.8 OCPD floor is 28.67 A (30 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.4 * (1 + (-0.284/100) * (-10 - 25)) = 53.21 V | OCPD = 1.56 * 18.38 = 28.67 A

Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21N-66HT705W: Voc=48.4 V, beta_Voc=-0.284%/C, Isc=18.38 A, STC=705.0 W, Area=3.03 m2.

Result: 11 panels max on 600 V (585.3 V); 12 panels for 8 kW (391 sq ft).

What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21N-66HT705W?

Official CEC datasheet figures for Hanersun Energy Co Ltd HN21N-66HT705W (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Hanersun Energy Co Ltd HN21N-66HT705W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 705.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 670.8 W (95.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 18.38 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.6 V / 17.37 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.284 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 23.27% (3.03 m2) Array roof footprint density
Cell Count & Technology 66 cells (Mono-c-Si) Monofacial backsheet

How Many Hanersun Energy Co Ltd HN21N-66HT705W Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Hanersun Energy Co Ltd HN21N-66HT705W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 9 6.34 kW 294 sq ft $1,587 $2,683
8 kW Class 12 8.46 kW 391 sq ft $2,117 $3,580
10 kW Class 15 10.57 kW 489 sq ft $2,646 $4,473

Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?

Consolidated Hanersun Energy Co Ltd wattage variants sharing the Hanersun Energy Co Ltd HN21N-66HT705W mechanical and cell layout.

Sibling CEC listings grouped into the Hanersun Energy Co Ltd HN21N-66HT705W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Hanersun Energy Co Ltd HN21N-66HT700W 700.0 W 665.9 W 48.2 V 40.4 V 23.1%
Hanersun Energy Co Ltd HN21N-66HT705W 705.0 W 670.8 W 48.4 V 40.6 V 23.27%

How Many Hanersun Energy Co Ltd HN21N-66HT705W Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Energy Co Ltd HN21N-66HT705W (53.21 V at 14 F).

Computed from Voc=48.4V and beta_Voc=-0.284%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.59 V 10 panels 545.9 V 18 panels
-10 C (14 F) 53.21 V 11 panels 585.3 V 18 panels
0 C (32 F) 51.84 V 11 panels 570.2 V 19 panels
25 C (77 F STC) 48.4 V 12 panels 580.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21N-66HT705W?

Competing CEC solar panels closest to Hanersun Energy Co Ltd HN21N-66HT705W in nameplate wattage and Voc, starting with Zetsol Energy Inc ZS-BG-T66705-G12.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Zetsol Energy Inc ZS-BG-T66705-G12
Zetsol Energy Inc
705.0 W Tie (0 W) 48.8 V 22.89% 95.2%
Solarspace Technology Co Ltd SS9-66HD-710N
Solarspace Technology Co Ltd
710.0 W +5.0 W 48.6 V 23.05% 94.7%
Zetsol Energy Inc ZS-BG-T66700-G12
Zetsol Energy Inc
700.0 W -5.0 W 48.6 V 22.73% 95.2%
New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12
New East Solar Energy (Cambodia) CoLtd
710.0 W +5.0 W 48.7 V 23.05% 95.1%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21N-66HT705W?

Evaluate Hanersun Energy Co Ltd HN21N-66HT705W (705.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21N-66HT705W reaches 54.59 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21N-66HT705W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Hanersun Energy Co Ltd HN21N-66HT705W 8 kW Residential Fit

Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,117/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Zetsol Energy Inc ZS-BG-T66705-G12.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 670.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Hanersun Energy Co Ltd HN21N-66HT705W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN21N-66HT705W?

Multiplying Hanersun Energy Co Ltd HN21N-66HT705W's 18.38 A short-circuit current by 1.56 equals 28.67 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.

Can Hanersun Energy Co Ltd HN21N-66HT705W pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.21 V cold Voc at 14 F and handles 18.38 A Isc; string inverters cap Hanersun Energy Co Ltd HN21N-66HT705W at 11 panels on 600 V.

Is Hanersun Energy Co Ltd HN21N-66HT705W eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN21N-66HT705W rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.