Hanersun Energy Co Ltd HN21N-66HT705W is a 705.0 W STC (670.8 W PTC) Mono-c-Si solar module ranking #166 of 21,677 CEC listings (top 0.9%; higher than 99.1% of peers). It delivers 23.27% efficiency, 48.4 V Voc at 25 C, and 53.21 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 705.0 W
- PTC Wattage
- 670.8 W
- Voc @ 25C
- 48.4 V
- Efficiency
- 23.27%
How Does Hanersun Energy Co Ltd HN21N-66HT705W Compare Against Peer CEC Listings?
Solar engineering breakdown for Hanersun Energy Co Ltd HN21N-66HT705W: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hanersun Energy Co Ltd and peers, Hanersun Energy Co Ltd HN21N-66HT705W stands 295.0 W above the 410.0 W Mono-c-Si median and strong 95.1% PTC-to-STC heat retention (#713 of 21,677). Sizing 6 kW (9 panels) to 10 kW (15 panels) yields $1,587-$2,646/yr in baseline US bill offset. Higher 48.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).
Where Does Hanersun Energy Co Ltd HN21N-66HT705W Fall Across Listed CEC Models?
Distribution marker showing Hanersun Energy Co Ltd HN21N-66HT705W (705.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hanersun Energy Co Ltd HN21N-66HT705W?
Dataset percentiles tracking Hanersun Energy Co Ltd HN21N-66HT705W power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21N-66HT705W?
Benchmark highlights for Hanersun Energy Co Ltd HN21N-66HT705W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 0.9% STC Output
705.0 W STC (+320.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
23.27% Aperture Efficiency
Power density 232.7 W/m2 (3.36 percentage points above 19.91% CEC median). PTC/STC ratio: 95.1% (rank #713).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.21 V at -10 C (585.3 V string) and 54.59 V at -20 C (10 max).
12 Panels = 8,460 W STC
Occupies 36.4 m2 (391 sq ft) producing 8,050 W PTC; NEC 690.8 OCPD floor is 28.67 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 48.4 * (1 + (-0.284/100) * (-10 - 25)) = 53.21 V | OCPD = 1.56 * 18.38 = 28.67 A
Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21N-66HT705W: Voc=48.4 V, beta_Voc=-0.284%/C, Isc=18.38 A, STC=705.0 W, Area=3.03 m2.
Result: 11 panels max on 600 V (585.3 V); 12 panels for 8 kW (391 sq ft).
What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21N-66HT705W?
Official CEC datasheet figures for Hanersun Energy Co Ltd HN21N-66HT705W (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 705.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 670.8 W (95.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 48.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.38 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 17.37 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.284 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 23.27% (3.03 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Monofacial backsheet |
How Many Hanersun Energy Co Ltd HN21N-66HT705W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hanersun Energy Co Ltd HN21N-66HT705W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 9 | 6.34 kW | 294 sq ft | $1,587 | $2,683 |
| 8 kW Class | 12 | 8.46 kW | 391 sq ft | $2,117 | $3,580 |
| 10 kW Class | 15 | 10.57 kW | 489 sq ft | $2,646 | $4,473 |
Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?
Consolidated Hanersun Energy Co Ltd wattage variants sharing the Hanersun Energy Co Ltd HN21N-66HT705W mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN21N-66HT700W | 700.0 W | 665.9 W | 48.2 V | 40.4 V | 23.1% |
| Hanersun Energy Co Ltd HN21N-66HT705W | 705.0 W | 670.8 W | 48.4 V | 40.6 V | 23.27% |
How Many Hanersun Energy Co Ltd HN21N-66HT705W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Energy Co Ltd HN21N-66HT705W (53.21 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.59 V | 10 panels | 545.9 V | 18 panels |
| -10 C (14 F) | 53.21 V | 11 panels | 585.3 V | 18 panels |
| 0 C (32 F) | 51.84 V | 11 panels | 570.2 V | 19 panels |
| 25 C (77 F STC) | 48.4 V | 12 panels | 580.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21N-66HT705W?
Competing CEC solar panels closest to Hanersun Energy Co Ltd HN21N-66HT705W in nameplate wattage and Voc, starting with Zetsol Energy Inc ZS-BG-T66705-G12.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Zetsol Energy Inc ZS-BG-T66705-G12 Zetsol Energy Inc |
705.0 W | Tie (0 W) | 48.8 V | 22.89% | 95.2% |
| Solarspace Technology Co Ltd SS9-66HD-710N Solarspace Technology Co Ltd |
710.0 W | +5.0 W | 48.6 V | 23.05% | 94.7% |
| Zetsol Energy Inc ZS-BG-T66700-G12 Zetsol Energy Inc |
700.0 W | -5.0 W | 48.6 V | 22.73% | 95.2% |
| New East Solar Energy (Cambodia) CoLtd NESE710-66THB-G12 New East Solar Energy (Cambodia) CoLtd |
710.0 W | +5.0 W | 48.7 V | 23.05% | 95.1% |
What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21N-66HT705W?
Evaluate Hanersun Energy Co Ltd HN21N-66HT705W (705.0 W STC, 48.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21N-66HT705W reaches 54.59 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 12 panels for an 8 kW build require 391 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21N-66HT705W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanersun Energy Co Ltd HN21N-66HT705W 8 kW Residential Fit
Needs 12 modules (391 sq ft) with a 30 A string OCPD, offsetting ~$2,117/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Zetsol Energy Inc ZS-BG-T66705-G12.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 670.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanersun Energy Co Ltd HN21N-66HT705W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN21N-66HT705W?
Multiplying Hanersun Energy Co Ltd HN21N-66HT705W's 18.38 A short-circuit current by 1.56 equals 28.67 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Hanersun Energy Co Ltd HN21N-66HT705W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 53.21 V cold Voc at 14 F and handles 18.38 A Isc; string inverters cap Hanersun Energy Co Ltd HN21N-66HT705W at 11 panels on 600 V.
Is Hanersun Energy Co Ltd HN21N-66HT705W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN21N-66HT705W rely on utility bill offset (~$2,117/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)