Hanersun Energy Co Ltd HN21-66HT640W is a 640.0 W STC (604.2 W PTC) Mono-c-Si solar module ranking #638 of 21,677 CEC listings (top 3.3%; higher than 96.7% of peers). It delivers 21.12% efficiency, 44.6 V Voc at 25 C, and 48.53 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 640.0 W
- PTC Wattage
- 604.2 W
- Voc @ 25C
- 44.6 V
- Efficiency
- 21.12%
How Does Hanersun Energy Co Ltd HN21-66HT640W Compare Against Peer CEC Listings?
Solar engineering breakdown for Hanersun Energy Co Ltd HN21-66HT640W: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 5,889 Mono-c-Si listings from Hanersun Energy Co Ltd and peers, Hanersun Energy Co Ltd HN21-66HT640W stands 230.0 W above the 410.0 W Mono-c-Si median and strong 94.4% PTC-to-STC heat retention (#2,840 of 21,677). Sizing 6 kW (10 panels) to 10 kW (16 panels) yields $1,602-$2,563/yr in baseline US bill offset. Mid-range 44.6 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.
Where Does Hanersun Energy Co Ltd HN21-66HT640W Fall Across Listed CEC Models?
Distribution marker showing Hanersun Energy Co Ltd HN21-66HT640W (640.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Hanersun Energy Co Ltd HN21-66HT640W?
Dataset percentiles tracking Hanersun Energy Co Ltd HN21-66HT640W power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Hanersun Energy Co Ltd HN21-66HT640W?
Benchmark highlights for Hanersun Energy Co Ltd HN21-66HT640W covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 3.3% STC Output
640.0 W STC (+255.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.12% Aperture Efficiency
Power density 211.2 W/m2 (1.21 percentage points above 19.91% CEC median). PTC/STC ratio: 94.4% (rank #2,840).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 48.53 V at -10 C (582.4 V string) and 49.66 V at -20 C (12 max).
13 Panels = 8,320 W STC
Occupies 39.4 m2 (424 sq ft) producing 7,855 W PTC; NEC 690.8 OCPD floor is 28.56 A (30 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 44.6 * (1 + (-0.252/100) * (-10 - 25)) = 48.53 V | OCPD = 1.56 * 18.31 = 28.56 A
Inputs from CEC Modules.csv for Hanersun Energy Co Ltd HN21-66HT640W: Voc=44.6 V, beta_Voc=-0.252%/C, Isc=18.31 A, STC=640.0 W, Area=3.03 m2.
Result: 12 panels max on 600 V (582.4 V); 13 panels for 8 kW (424 sq ft).
What Are the Published CEC Specifications for Hanersun Energy Co Ltd HN21-66HT640W?
Official CEC datasheet figures for Hanersun Energy Co Ltd HN21-66HT640W (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 640.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 604.2 W (94.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 44.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 18.31 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.5 V / 17.07 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.252 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.12% (3.03 m2) | Array roof footprint density |
| Cell Count & Technology | 66 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Hanersun Energy Co Ltd HN21-66HT640W Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Hanersun Energy Co Ltd HN21-66HT640W modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.4 kW | 326 sq ft | $1,602 | $2,709 |
| 8 kW Class | 13 | 8.32 kW | 424 sq ft | $2,082 | $3,521 |
| 10 kW Class | 16 | 10.24 kW | 522 sq ft | $2,563 | $4,334 |
Which Sibling Wattage & Trim Variants Belong to This Hanersun Energy Co Ltd Series?
Consolidated Hanersun Energy Co Ltd wattage variants sharing the Hanersun Energy Co Ltd HN21-66HT640W mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Hanersun Energy Co Ltd HN21-66HT635W | 635.0 W | 599.4 W | 44.4 V | 37.3 V | 20.96% |
| Hanersun Energy Co Ltd HN21-66HT640W | 640.0 W | 604.2 W | 44.6 V | 37.5 V | 21.12% |
| Hanersun Energy Co Ltd HN21-66HT645W | 645.0 W | 609.1 W | 44.8 V | 37.7 V | 21.29% |
How Many Hanersun Energy Co Ltd HN21-66HT640W Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Hanersun Energy Co Ltd HN21-66HT640W (48.53 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 49.66 V | 12 panels | 595.9 V | 20 panels |
| -10 C (14 F) | 48.53 V | 12 panels | 582.4 V | 20 panels |
| 0 C (32 F) | 47.41 V | 12 panels | 568.9 V | 21 panels |
| 25 C (77 F STC) | 44.6 V | 13 panels | 579.8 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Hanersun Energy Co Ltd HN21-66HT640W?
Competing CEC solar panels closest to Hanersun Energy Co Ltd HN21-66HT640W in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS7N-640MB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS7N-640MB-AG CSI Solar Co Ltd |
640.0 W | Tie (0 W) | 44.6 V | 20.85% | 93.1% |
| Chint New Energy Technology Co Ltd CHSM66M(DG)/F-BH-640 Chint New Energy Technology Co Ltd |
640.0 W | Tie (0 W) | 45.09 V | 21.12% | 92.8% |
| LIGHT ENGINE ILUMINACAO SA HS66-F-645-MN LIGHT ENGINE ILUMINACAO SA |
645.0 W | +5.0 W | 44.8 V | 21.01% | 94.1% |
| CSI Solar Co Ltd CS7L-635TB-AG CSI Solar Co Ltd |
635.0 W | -5.0 W | 43.5 V | 23.09% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Hanersun Energy Co Ltd HN21-66HT640W?
Evaluate Hanersun Energy Co Ltd HN21-66HT640W (640.0 W STC, 44.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Hanersun Energy Co Ltd HN21-66HT640W reaches 49.66 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 424 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Hanersun Energy Co Ltd HN21-66HT640W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Hanersun Energy Co Ltd HN21-66HT640W 8 kW Residential Fit
Needs 13 modules (424 sq ft) with a 30 A string OCPD, offsetting ~$2,082/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS7N-640MB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 604.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Hanersun Energy Co Ltd HN21-66HT640W by Hanersun Energy Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Hanersun Energy Co Ltd HN21-66HT640W?
Multiplying Hanersun Energy Co Ltd HN21-66HT640W's 18.31 A short-circuit current by 1.56 equals 28.56 A minimum ampacity, requiring at least a 30 A overcurrent fuse or breaker.
Can Hanersun Energy Co Ltd HN21-66HT640W pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 48.53 V cold Voc at 14 F and handles 18.31 A Isc; string inverters cap Hanersun Energy Co Ltd HN21-66HT640W at 12 panels on 600 V.
Is Hanersun Energy Co Ltd HN21-66HT640W eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Hanersun Energy Co Ltd HN21-66HT640W rely on utility bill offset (~$2,082/yr at 8 kW) rather than 25D.