Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 156HC-630 M10 NTYP SL — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 156HC-630 M10 NTYP SL is a 630.0 W STC (598.8 W PTC) Mono-c-Si solar module ranking #783 of 21,677 CEC listings (top 4.0%; higher than 96.0% of peers). It delivers 22.74% efficiency, 55.95 V Voc at 25 C, and 60.67 V cold Voc at -10 C (9 panels max per 600 V string).

STC Wattage
630.0 W
PTC Wattage
598.8 W
Voc @ 25C
55.95 V
Efficiency
22.74%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 156HC-630 M10 NTYP SL Compare Against Peer CEC Listings?

Solar engineering breakdown for Heliene 156HC-630 M10 NTYP SL: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 630.0 W STC and 598.8 W PTC, Heliene 156HC-630 M10 NTYP SL sits +245.0 W vs all-CEC median (top 4.0%; higher than 96.0% of peers) among 21,677 listed modules. Power density reaches 227.4 W/m2 (2.83 percentage points above 19.91% CEC median). Higher 55.95 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 16 panels in series. Alternative peer Hansol Technics Co Ltd HA630AE-NGEA0 rates 630.0 W.

Where Does Heliene 156HC-630 M10 NTYP SL Fall Across Listed CEC Models?

Distribution marker showing Heliene 156HC-630 M10 NTYP SL (630.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 156HC-630 M10 NTYP SL (630.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 156HC-630 : 630.0 W

What Dataset Percentiles Define Heliene 156HC-630 M10 NTYP SL?

Dataset percentiles tracking Heliene 156HC-630 M10 NTYP SL power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Heliene 156HC-630 M10 NTYP SL Engineering BenchmarksPercentile comparison of Heliene 156HC-630 M10 NTYP SL wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage630.0 WPTC/STC Retention95.0%Module Efficiency22.74%

What Do the Dataset Ranks Show for Heliene 156HC-630 M10 NTYP SL?

Benchmark highlights for Heliene 156HC-630 M10 NTYP SL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #783 / 21,677

Top 4.0% STC Output

630.0 W STC (+245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #1,578

22.74% Aperture Efficiency

Power density 227.4 W/m2 (2.83 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).

NEC 690.7 Limit

9 Panels Max @ -10 C (600 V)

Cold Voc reaches 60.67 V at -10 C (546.0 V string) and 62.02 V at -20 C (9 max).

8 kW Reference Array

13 Panels = 8,190 W STC

Occupies 36.0 m2 (388 sq ft) producing 7,784 W PTC; NEC 690.8 OCPD floor is 22.35 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 55.95 * (1 + (-0.241/100) * (-10 - 25)) = 60.67 V | OCPD = 1.56 * 14.33 = 22.35 A

Inputs from CEC Modules.csv for Heliene 156HC-630 M10 NTYP SL: Voc=55.95 V, beta_Voc=-0.241%/C, Isc=14.33 A, STC=630.0 W, Area=2.77 m2.

Result: 9 panels max on 600 V (546.0 V); 13 panels for 8 kW (388 sq ft).

What Are the Published CEC Specifications for Heliene 156HC-630 M10 NTYP SL?

Official CEC datasheet figures for Heliene 156HC-630 M10 NTYP SL (Mono-c-Si) used in utility interconnection and permit reviews.

Official California Energy Commission (NREL SAM) test parameters for Heliene 156HC-630 M10 NTYP SL.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 630.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 598.8 W (95.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 55.95 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 47.01 V / 13.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.241 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 22.74% (2.77 m2) Array roof footprint density
Cell Count & Technology 78 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 156HC-630 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Heliene 156HC-630 M10 NTYP SL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 10 6.3 kW 298 sq ft $1,577 $2,666
8 kW Class 13 8.19 kW 388 sq ft $2,050 $3,466
10 kW Class 16 10.08 kW 477 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Consolidated Heliene wattage variants sharing the Heliene 156HC-630 M10 NTYP SL mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 156HC-630 M10 NTYP SL wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 156HC-625 M10 NTYP SL 625.0 W 593.9 W 55.8 V 46.75 V 22.56%
Heliene 156HC-630 M10 NTYP SL 630.0 W 598.8 W 55.95 V 47.01 V 22.74%
Heliene 156HC-635 M10 NTYP SL 635.0 W 603.7 W 56.11 V 47.19 V 22.92%

How Many Heliene 156HC-630 M10 NTYP SL Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 156HC-630 M10 NTYP SL (60.67 V at 14 F).

Computed from Voc=55.95V and beta_Voc=-0.241%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 62.02 V 9 panels 558.2 V 16 panels
-10 C (14 F) 60.67 V 9 panels 546.0 V 16 panels
0 C (32 F) 59.32 V 10 panels 593.2 V 16 panels
25 C (77 F STC) 55.95 V 10 panels 559.5 V 17 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 156HC-630 M10 NTYP SL?

Competing CEC solar panels closest to Heliene 156HC-630 M10 NTYP SL in nameplate wattage and Voc, starting with Hansol Technics Co Ltd HA630AE-NGEA0.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Hansol Technics Co Ltd HA630AE-NGEA0
Hansol Technics Co Ltd
630.0 W Tie (0 W) 55.9 V 22.74% 95.1%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-630
Jiangsu Runergy New Energy Technology Co Ltd
630.0 W Tie (0 W) 55.79 V 22.5% 95.0%
Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-630
Jiangsu Runergy New Energy Technology Co Ltd
630.0 W Tie (0 W) 55.79 V 22.5% 95.0%
Aptos Solar Technology LLC DNA-156-BFN10-630W-DG
Aptos Solar Technology LLC
630.0 W Tie (0 W) 55.55 V 22.5% 94.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 156HC-630 M10 NTYP SL?

Evaluate Heliene 156HC-630 M10 NTYP SL (630.0 W STC, 55.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 156HC-630 M10 NTYP SL reaches 62.02 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Heliene 156HC-630 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 156HC-630 M10 NTYP SL 8 kW Residential Fit

Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA630AE-NGEA0.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 598.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 156HC-630 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

How many Heliene 156HC-630 M10 NTYP SL panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 156HC-630 M10 NTYP SL cold Voc rises from 55.95 V to 60.67 V (beta_Voc -0.241%/C), capping a 600 V string at 9 panels (546.0 V).

How much roof area does an 8 kW array of Heliene 156HC-630 M10 NTYP SL need?

An 8 kW DC system uses 13 Heliene 156HC-630 M10 NTYP SL modules (8,190 W STC / 7,784 W PTC), covering roughly 388 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Heliene 156HC-630 M10 NTYP SL compare against Hansol Technics Co Ltd HA630AE-NGEA0?

Heliene 156HC-630 M10 NTYP SL outputs 630.0 W STC (55.95 V Voc, rank #783 of 21,677), while Hansol Technics Co Ltd HA630AE-NGEA0 delivers 630.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.