Heliene 156HC-630 M10 NTYP SL is a 630.0 W STC (598.8 W PTC) Mono-c-Si solar module ranking #783 of 21,677 CEC listings (top 4.0%; higher than 96.0% of peers). It delivers 22.74% efficiency, 55.95 V Voc at 25 C, and 60.67 V cold Voc at -10 C (9 panels max per 600 V string).
- STC Wattage
- 630.0 W
- PTC Wattage
- 598.8 W
- Voc @ 25C
- 55.95 V
- Efficiency
- 22.74%
How Does Heliene 156HC-630 M10 NTYP SL Compare Against Peer CEC Listings?
Solar engineering breakdown for Heliene 156HC-630 M10 NTYP SL: PTC thermal retention, roof footprint, and cold Voc string bounds.
Measured at 630.0 W STC and 598.8 W PTC, Heliene 156HC-630 M10 NTYP SL sits +245.0 W vs all-CEC median (top 4.0%; higher than 96.0% of peers) among 21,677 listed modules. Power density reaches 227.4 W/m2 (2.83 percentage points above 19.91% CEC median). Higher 55.95 V open-circuit voltage caps 600 V residential strings at 9 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 16 panels in series. Alternative peer Hansol Technics Co Ltd HA630AE-NGEA0 rates 630.0 W.
Where Does Heliene 156HC-630 M10 NTYP SL Fall Across Listed CEC Models?
Distribution marker showing Heliene 156HC-630 M10 NTYP SL (630.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define Heliene 156HC-630 M10 NTYP SL?
Dataset percentiles tracking Heliene 156HC-630 M10 NTYP SL power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for Heliene 156HC-630 M10 NTYP SL?
Benchmark highlights for Heliene 156HC-630 M10 NTYP SL covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
Top 4.0% STC Output
630.0 W STC (+245.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
22.74% Aperture Efficiency
Power density 227.4 W/m2 (2.83 percentage points above 19.91% CEC median). PTC/STC ratio: 95.0% (rank #1,106).
9 Panels Max @ -10 C (600 V)
Cold Voc reaches 60.67 V at -10 C (546.0 V string) and 62.02 V at -20 C (9 max).
13 Panels = 8,190 W STC
Occupies 36.0 m2 (388 sq ft) producing 7,784 W PTC; NEC 690.8 OCPD floor is 22.35 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 55.95 * (1 + (-0.241/100) * (-10 - 25)) = 60.67 V | OCPD = 1.56 * 14.33 = 22.35 A
Inputs from CEC Modules.csv for Heliene 156HC-630 M10 NTYP SL: Voc=55.95 V, beta_Voc=-0.241%/C, Isc=14.33 A, STC=630.0 W, Area=2.77 m2.
Result: 9 panels max on 600 V (546.0 V); 13 panels for 8 kW (388 sq ft).
What Are the Published CEC Specifications for Heliene 156HC-630 M10 NTYP SL?
Official CEC datasheet figures for Heliene 156HC-630 M10 NTYP SL (Mono-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 630.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 598.8 W (95.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 55.95 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 14.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 47.01 V / 13.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.241 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 22.74% (2.77 m2) | Array roof footprint density |
| Cell Count & Technology | 78 cells (Mono-c-Si) | Monofacial backsheet |
How Many Heliene 156HC-630 M10 NTYP SL Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Heliene 156HC-630 M10 NTYP SL modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 10 | 6.3 kW | 298 sq ft | $1,577 | $2,666 |
| 8 kW Class | 13 | 8.19 kW | 388 sq ft | $2,050 | $3,466 |
| 10 kW Class | 16 | 10.08 kW | 477 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This Heliene Series?
Consolidated Heliene wattage variants sharing the Heliene 156HC-630 M10 NTYP SL mechanical and cell layout. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Heliene 156HC-625 M10 NTYP SL | 625.0 W | 593.9 W | 55.8 V | 46.75 V | 22.56% |
| Heliene 156HC-630 M10 NTYP SL | 630.0 W | 598.8 W | 55.95 V | 47.01 V | 22.74% |
| Heliene 156HC-635 M10 NTYP SL | 635.0 W | 603.7 W | 56.11 V | 47.19 V | 22.92% |
How Many Heliene 156HC-630 M10 NTYP SL Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Heliene 156HC-630 M10 NTYP SL (60.67 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 62.02 V | 9 panels | 558.2 V | 16 panels |
| -10 C (14 F) | 60.67 V | 9 panels | 546.0 V | 16 panels |
| 0 C (32 F) | 59.32 V | 10 panels | 593.2 V | 16 panels |
| 25 C (77 F STC) | 55.95 V | 10 panels | 559.5 V | 17 panels |
Which Cross-Brand Solar Modules Compare Closest to Heliene 156HC-630 M10 NTYP SL?
Competing CEC solar panels closest to Heliene 156HC-630 M10 NTYP SL in nameplate wattage and Voc, starting with Hansol Technics Co Ltd HA630AE-NGEA0.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Hansol Technics Co Ltd HA630AE-NGEA0 Hansol Technics Co Ltd |
630.0 W | Tie (0 W) | 55.9 V | 22.74% | 95.1% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8-630 Jiangsu Runergy New Energy Technology Co Ltd |
630.0 W | Tie (0 W) | 55.79 V | 22.5% | 95.0% |
| Jiangsu Runergy New Energy Technology Co Ltd HY-DH156N8T-630 Jiangsu Runergy New Energy Technology Co Ltd |
630.0 W | Tie (0 W) | 55.79 V | 22.5% | 95.0% |
| Aptos Solar Technology LLC DNA-156-BFN10-630W-DG Aptos Solar Technology LLC |
630.0 W | Tie (0 W) | 55.55 V | 22.5% | 94.9% |
What Are the Design Limits and Best-Fit Uses for Heliene 156HC-630 M10 NTYP SL?
Evaluate Heliene 156HC-630 M10 NTYP SL (630.0 W STC, 55.95 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Heliene 156HC-630 M10 NTYP SL reaches 62.02 V per panel—exceeding 9 panels in series voids 600 V inverter warranties.
- Footprint constraint: 13 panels for an 8 kW build require 388 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Heliene 156HC-630 M10 NTYP SL carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Heliene 156HC-630 M10 NTYP SL 8 kW Residential Fit
Needs 13 modules (388 sq ft) with a 25 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 9 panels (-10 C) or 9 panels (-20 C), or compare Hansol Technics Co Ltd HA630AE-NGEA0.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 598.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Heliene 156HC-630 M10 NTYP SL by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.
How many Heliene 156HC-630 M10 NTYP SL panels fit on a 600 V winter solar string?
At -10 C (14 F), Heliene 156HC-630 M10 NTYP SL cold Voc rises from 55.95 V to 60.67 V (beta_Voc -0.241%/C), capping a 600 V string at 9 panels (546.0 V).
How much roof area does an 8 kW array of Heliene 156HC-630 M10 NTYP SL need?
An 8 kW DC system uses 13 Heliene 156HC-630 M10 NTYP SL modules (8,190 W STC / 7,784 W PTC), covering roughly 388 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Heliene 156HC-630 M10 NTYP SL compare against Hansol Technics Co Ltd HA630AE-NGEA0?
Heliene 156HC-630 M10 NTYP SL outputs 630.0 W STC (55.95 V Voc, rank #783 of 21,677), while Hansol Technics Co Ltd HA630AE-NGEA0 delivers 630.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)