AXITEC AC-435MH/144V is a 435.0 W STC (401.8 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.52% efficiency, 49.4 V Voc at 25 C, and 54.22 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 435.0 W
- PTC Wattage
- 401.8 W
- Voc @ 25C
- 49.4 V
- Efficiency
- 20.52%
How Does AXITEC AC-435MH/144V Compare Against Peer CEC Listings?
How AXITEC AXITEC AC-435MH/144V handles rooftop heat (401.8 W PTC), 8 kW sizing, and cold winter string voltage.
AXITEC builds the AXITEC AC-435MH/144V (Mono-c-Si) as a modern high-density residential and light-commercial module delivering 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). Compared against Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W (435.0 W), this model holds strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), while NEC 690.8 sets a 17.57 A overcurrent floor served by a 20 A breaker.
Where Does AXITEC AC-435MH/144V Fall Across Listed CEC Models?
Where AXITEC AC-435MH/144V (435.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-435MH/144V?
Percentile placement of AXITEC AC-435MH/144V across power density (205.2 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for AXITEC AC-435MH/144V?
Four critical engineering numbers homeowners and solar installers check first when reviewing AXITEC AC-435MH/144V specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 33.5% STC Output
435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.52% Aperture Efficiency
Power density 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.22 V at -10 C (596.4 V string) and 55.6 V at -20 C (10 max).
19 Panels = 8,265 W STC
Occupies 40.3 m2 (434 sq ft) producing 7,634 W PTC; NEC 690.8 OCPD floor is 17.57 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.4 * (1 + (-0.279/100) * (-10 - 25)) = 54.22 V | OCPD = 1.56 * 11.26 = 17.57 A
Inputs from CEC Modules.csv for AXITEC AC-435MH/144V: Voc=49.4 V, beta_Voc=-0.279%/C, Isc=11.26 A, STC=435.0 W, Area=2.12 m2.
Result: 11 panels max on 600 V (596.4 V); 19 panels for 8 kW (434 sq ft).
What Are the Published CEC Specifications for AXITEC AC-435MH/144V?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for AXITEC AC-435MH/144V.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 435.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 401.8 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.26 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.8 V / 10.67 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.52% (2.12 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-435MH/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using AXITEC AC-435MH/144V (435.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.09 kW | 319 sq ft | $1,524 | $2,577 |
| 8 kW Class | 19 | 8.27 kW | 434 sq ft | $2,070 | $3,500 |
| 10 kW Class | 23 | 10.01 kW | 525 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
All closely matched AXITEC wattages and cosmetic trims sharing the AXITEC AC-435MH/144V architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-425MH/144V | 425.0 W | 392.3 W | 48.3 V | 40.5 V | 20.05% |
| AXITEC AC-430MH/144V | 430.0 W | 397.0 W | 49.2 V | 40.6 V | 20.28% |
| AXITEC AC-435MH/144V | 435.0 W | 401.8 W | 49.4 V | 40.8 V | 20.52% |
| AXITEC AC-440MH/144V | 440.0 W | 406.6 W | 49.6 V | 41.0 V | 20.75% |
| AXITEC AC-445MH/144V | 445.0 W | 411.3 W | 49.8 V | 41.2 V | 20.99% |
How Many AXITEC AC-435MH/144V Modules Fit in a Cold-Weather String?
Maximum series module counts for AXITEC AC-435MH/144V from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.6 V | 10 panels | 556.0 V | 17 panels |
| -10 C (14 F) | 54.22 V | 11 panels | 596.4 V | 18 panels |
| 0 C (32 F) | 52.85 V | 11 panels | 581.4 V | 18 panels |
| 25 C (77 F STC) | 49.4 V | 12 panels | 592.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-435MH/144V?
Alternative CEC solar modules from competing brands near AXITEC AC-435MH/144V (435.0 W), including Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W Dehui Solar Power (Vietnam) CoLtd |
435.0 W | Tie (0 W) | 49.4 V | 20.52% | 92.4% |
| DualSun SAS DualSun 435M-144-01 DualSun SAS |
435.0 W | Tie (0 W) | 49.4 V | 20.14% | 93.9% |
| Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W Dehui Solar Power (Vietnam) CoLtd |
435.0 W | Tie (0 W) | 49.1 V | 20.33% | 92.6% |
| Aptos Solar Technology LLC DNA-144-MF26-435W {Blk} Aptos Solar Technology LLC |
435.0 W | Tie (0 W) | 49.7 V | 20.71% | 91.8% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-435MH/144V?
Evaluate AXITEC AC-435MH/144V (435.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-435MH/144V reaches 55.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (434 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of AXITEC AC-435MH/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-435MH/144V 8 kW Residential Fit
Needs 19 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 401.8 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-435MH/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-435MH/144V?
Multiplying AXITEC AC-435MH/144V's 11.26 A short-circuit current by 1.56 equals 17.57 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can AXITEC AC-435MH/144V pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 54.22 V cold Voc at 14 F and handles 11.26 A Isc; string inverters cap AXITEC AC-435MH/144V at 11 panels on 600 V.
Is AXITEC AC-435MH/144V eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-435MH/144V rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)