Manufacturer: DualSun SAS Registry: CEC Verified Engineering Specification

DualSun SAS DualSun 435M-144-01 is a 435.0 W STC (408.5 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.14% efficiency, 49.4 V Voc at 25 C, and 54.03 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
408.5 W
Voc @ 25C
49.4 V
Efficiency
20.14%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DualSun SAS DualSun 435M-144-01 Compare Against Peer CEC Listings?

Solar engineering breakdown for DualSun SAS DualSun 435M-144-01: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 435.0 W STC and 408.5 W PTC, DualSun SAS DualSun 435M-144-01 sits +50.0 W vs all-CEC median (top 33.5%; higher than 66.5% of peers) among 21,677 listed modules. Power density reaches 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). Higher 49.4 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer AXITEC AC-435MH/144V rates 435.0 W.

Where Does DualSun SAS DualSun 435M-144-01 Fall Across Listed CEC Models?

Distribution marker showing DualSun SAS DualSun 435M-144-01 (435.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where DualSun SAS DualSun 435M-144-01 (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCDualSun SAS DualSu: 435.0 W

What Dataset Percentiles Define DualSun SAS DualSun 435M-144-01?

Dataset percentiles tracking DualSun SAS DualSun 435M-144-01 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

DualSun SAS DualSun 435M-144-01 Engineering BenchmarksPercentile comparison of DualSun SAS DualSun 435M-144-01 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention93.9%Module Efficiency20.14%

What Do the Dataset Ranks Show for DualSun SAS DualSun 435M-144-01?

Benchmark highlights for DualSun SAS DualSun 435M-144-01 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #9,983

20.14% Aperture Efficiency

Power density 201.4 W/m2 (0.23 percentage points above 19.91% CEC median). PTC/STC ratio: 93.9% (rank #5,210).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.03 V at -10 C (594.3 V string) and 55.36 V at -20 C (10 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 41.0 m2 (442 sq ft) producing 7,762 W PTC; NEC 690.8 OCPD floor is 17.57 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.4 * (1 + (-0.268/100) * (-10 - 25)) = 54.03 V | OCPD = 1.56 * 11.26 = 17.57 A

Inputs from CEC Modules.csv for DualSun SAS DualSun 435M-144-01: Voc=49.4 V, beta_Voc=-0.268%/C, Isc=11.26 A, STC=435.0 W, Area=2.16 m2.

Result: 11 panels max on 600 V (594.3 V); 19 panels for 8 kW (442 sq ft).

What Are the Published CEC Specifications for DualSun SAS DualSun 435M-144-01?

Official CEC datasheet figures for DualSun SAS DualSun 435M-144-01 (Mono-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DualSun 435M-144-01.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 408.5 W (93.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.26 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.8 V / 10.67 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.268 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.14% (2.16 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many DualSun SAS DualSun 435M-144-01 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many DualSun SAS DualSun 435M-144-01 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 326 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 442 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 535 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?

Consolidated DualSun SAS wattage variants sharing the DualSun SAS DualSun 435M-144-01 mechanical and cell layout. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the DualSun SAS DualSun 435M-144-01 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
DualSun SAS DualSun 425M-144-01 425.0 W 398.9 W 49.0 V 40.4 V 19.68%
DualSun SAS DualSun 430M-144-01 430.0 W 403.7 W 49.2 V 40.6 V 19.91%
DualSun SAS DualSun 435M-144-01 435.0 W 408.5 W 49.4 V 40.8 V 20.14%
DualSun SAS DualSun 440M-144-01 440.0 W 413.3 W 49.6 V 41.0 V 20.37%

How Many DualSun SAS DualSun 435M-144-01 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DualSun 435M-144-01 (54.03 V at 14 F).

Computed from Voc=49.4V and beta_Voc=-0.268%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.36 V 10 panels 553.6 V 18 panels
-10 C (14 F) 54.03 V 11 panels 594.3 V 18 panels
0 C (32 F) 52.71 V 11 panels 579.8 V 18 panels
25 C (77 F STC) 49.4 V 12 panels 592.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 435M-144-01?

Competing CEC solar panels closest to DualSun SAS DualSun 435M-144-01 in nameplate wattage and Voc, starting with AXITEC AC-435MH/144V.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
AXITEC AC-435MH/144V
AXITEC
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
Dehui Solar Power (Vietnam) CoLtd DH-M772W 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.4 V 20.52% 92.4%
AXITEC AC-435MB/144V
AXITEC
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 435M-144-01?

Evaluate DualSun SAS DualSun 435M-144-01 (435.0 W STC, 49.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 435M-144-01 reaches 55.36 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 435M-144-01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

DualSun SAS DualSun 435M-144-01 8 kW Residential Fit

Needs 19 modules (442 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare AXITEC AC-435MH/144V.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 408.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DualSun 435M-144-01 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

How many DualSun SAS DualSun 435M-144-01 panels fit on a 600 V winter solar string?

At -10 C (14 F), DualSun SAS DualSun 435M-144-01 cold Voc rises from 49.4 V to 54.03 V (beta_Voc -0.268%/C), capping a 600 V string at 11 panels (594.3 V).

How much roof area does an 8 kW array of DualSun SAS DualSun 435M-144-01 need?

An 8 kW DC system uses 19 DualSun SAS DualSun 435M-144-01 modules (8,265 W STC / 7,762 W PTC), covering roughly 442 sq ft and saving ~$2,070/yr at 18.54 c/kWh.

How does DualSun SAS DualSun 435M-144-01 compare against AXITEC AC-435MH/144V?

DualSun SAS DualSun 435M-144-01 outputs 435.0 W STC (49.4 V Voc, rank #6,850 of 21,677), while AXITEC AC-435MH/144V delivers 435.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.