DualSun SAS DSTN425M12-B320SBB7 is a 425.0 W STC (372.6 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 21.04% efficiency, 43.4 V Voc at 25 C, and 47.73 V cold Voc at -10 C (12 panels max per 600 V string).
- STC Wattage
- 425.0 W
- PTC Wattage
- 372.6 W
- Voc @ 25C
- 43.4 V
- Efficiency
- 21.04%
How Does DualSun SAS DSTN425M12-B320SBB7 Compare Against Peer CEC Listings?
Solar engineering breakdown for DualSun SAS DSTN425M12-B320SBB7: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.
Measured at 425.0 W STC and 372.6 W PTC, DualSun SAS DSTN425M12-B320SBB7 sits +40.0 W vs all-CEC median (top 36.5%; higher than 63.5% of peers) among 21,677 listed modules. Power density reaches 210.4 W/m2 (1.13 percentage points above 19.91% CEC median). Mid-range 43.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS3N-430MS rates 430.0 W.
Where Does DualSun SAS DSTN425M12-B320SBB7 Fall Across Listed CEC Models?
Distribution marker showing DualSun SAS DSTN425M12-B320SBB7 (425.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define DualSun SAS DSTN425M12-B320SBB7?
Dataset percentiles tracking DualSun SAS DSTN425M12-B320SBB7 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for DualSun SAS DSTN425M12-B320SBB7?
Benchmark highlights for DualSun SAS DSTN425M12-B320SBB7 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Top 36.5% STC Output
425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.04% Aperture Efficiency
Power density 210.4 W/m2 (1.13 percentage points above 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).
12 Panels Max @ -10 C (600 V)
Cold Voc reaches 47.73 V at -10 C (572.8 V string) and 48.97 V at -20 C (12 max).
19 Panels = 8,075 W STC
Occupies 38.4 m2 (413 sq ft) producing 7,079 W PTC; NEC 690.8 OCPD floor is 19.59 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 43.4 * (1 + (-0.285/100) * (-10 - 25)) = 47.73 V | OCPD = 1.56 * 12.56 = 19.59 A
Inputs from CEC Modules.csv for DualSun SAS DSTN425M12-B320SBB7: Voc=43.4 V, beta_Voc=-0.285%/C, Isc=12.56 A, STC=425.0 W, Area=2.02 m2.
Result: 12 panels max on 600 V (572.8 V); 19 panels for 8 kW (413 sq ft).
What Are the Published CEC Specifications for DualSun SAS DSTN425M12-B320SBB7?
Official CEC datasheet figures for DualSun SAS DSTN425M12-B320SBB7 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 425.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 372.6 W (87.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 43.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 12.56 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.0 V / 11.81 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.285 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.04% (2.02 m2) | Array roof footprint density |
| Cell Count & Technology | 32 cells (Mono-c-Si) | Monofacial backsheet |
How Many DualSun SAS DSTN425M12-B320SBB7 Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many DualSun SAS DSTN425M12-B320SBB7 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 15 | 6.38 kW | 326 sq ft | $1,597 | $2,700 |
| 8 kW Class | 19 | 8.07 kW | 413 sq ft | $2,020 | $3,415 |
| 10 kW Class | 24 | 10.2 kW | 522 sq ft | $2,553 | $4,317 |
How Many DualSun SAS DSTN425M12-B320SBB7 Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DSTN425M12-B320SBB7 (47.73 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 48.97 V | 12 panels | 587.6 V | 20 panels |
| -10 C (14 F) | 47.73 V | 12 panels | 572.8 V | 20 panels |
| 0 C (32 F) | 46.49 V | 12 panels | 557.9 V | 21 panels |
| 25 C (77 F STC) | 43.4 V | 13 panels | 564.2 V | 23 panels |
Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DSTN425M12-B320SBB7?
Competing CEC solar panels closest to DualSun SAS DSTN425M12-B320SBB7 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-430MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3N-430MS CSI Solar Co Ltd |
430.0 W | +5.0 W | 45.7 V | 21.83% | 93.7% |
| Boviet Solar Technology Co Ltd BVM7610M-435-H-HC Boviet Solar Technology Co Ltd |
435.0 W | +10.0 W | 41.21 V | 20.71% | 94.0% |
| AE Solar GmbH AE420CMD-108BDE AE Solar GmbH |
420.0 W | -5.0 W | 39.7 V | 21.54% | 94.8% |
| CertainTeed CTM10435HC11-06 CertainTeed |
435.0 W | +10.0 W | 40.95 V | 20.14% | 93.7% |
What Are the Design Limits and Best-Fit Uses for DualSun SAS DSTN425M12-B320SBB7?
Evaluate DualSun SAS DSTN425M12-B320SBB7 (425.0 W STC, 43.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DSTN425M12-B320SBB7 reaches 48.97 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (413 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of DualSun SAS DSTN425M12-B320SBB7 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
DualSun SAS DSTN425M12-B320SBB7 8 kW Residential Fit
Needs 19 modules (413 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-430MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for DualSun SAS DSTN425M12-B320SBB7 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.
How many DualSun SAS DSTN425M12-B320SBB7 panels fit on a 600 V winter solar string?
At -10 C (14 F), DualSun SAS DSTN425M12-B320SBB7 cold Voc rises from 43.4 V to 47.73 V (beta_Voc -0.285%/C), capping a 600 V string at 12 panels (572.8 V).
How much roof area does an 8 kW array of DualSun SAS DSTN425M12-B320SBB7 need?
An 8 kW DC system uses 19 DualSun SAS DSTN425M12-B320SBB7 modules (8,075 W STC / 7,079 W PTC), covering roughly 413 sq ft and saving ~$2,020/yr at 18.54 c/kWh.
How does DualSun SAS DSTN425M12-B320SBB7 compare against CSI Solar Co Ltd CS3N-430MS?
DualSun SAS DSTN425M12-B320SBB7 outputs 425.0 W STC (43.4 V Voc, rank #7,622 of 21,677), while CSI Solar Co Ltd CS3N-430MS delivers 430.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)