Skip to main content
WireAndSun
Calculators
CEC PV Module

DualSun SAS DSTN425M12-B320SBB7 — CEC Solar Module Specifications

Manufacturer: DualSun SAS Registry: CEC Verified Engineering Specification

DualSun SAS DSTN425M12-B320SBB7 is a 425.0 W STC (372.6 W PTC) Mono-c-Si solar module ranking #7,622 of 21,677 CEC listings (top 36.5%; higher than 63.5% of peers). It delivers 21.04% efficiency, 43.4 V Voc at 25 C, and 47.73 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
425.0 W
PTC Wattage
372.6 W
Voc @ 25C
43.4 V
Efficiency
21.04%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DualSun SAS DSTN425M12-B320SBB7 Compare Against Peer CEC Listings?

Solar engineering breakdown for DualSun SAS DSTN425M12-B320SBB7: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Measured at 425.0 W STC and 372.6 W PTC, DualSun SAS DSTN425M12-B320SBB7 sits +40.0 W vs all-CEC median (top 36.5%; higher than 63.5% of peers) among 21,677 listed modules. Power density reaches 210.4 W/m2 (1.13 percentage points above 19.91% CEC median). Mid-range 43.4 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 20 panels in series. Alternative peer CSI Solar Co Ltd CS3N-430MS rates 430.0 W.

Where Does DualSun SAS DSTN425M12-B320SBB7 Fall Across Listed CEC Models?

Distribution marker showing DualSun SAS DSTN425M12-B320SBB7 (425.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where DualSun SAS DSTN425M12-B320SBB7 (425.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCDualSun SAS DSTN42: 425.0 W

What Dataset Percentiles Define DualSun SAS DSTN425M12-B320SBB7?

Dataset percentiles tracking DualSun SAS DSTN425M12-B320SBB7 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

DualSun SAS DSTN425M12-B320SBB7 Engineering BenchmarksPercentile comparison of DualSun SAS DSTN425M12-B320SBB7 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage425.0 WPTC/STC Retention87.7%Module Efficiency21.04%

What Do the Dataset Ranks Show for DualSun SAS DSTN425M12-B320SBB7?

Benchmark highlights for DualSun SAS DSTN425M12-B320SBB7 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #7,622 / 21,677

Top 36.5% STC Output

425.0 W STC (+40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #6,220

21.04% Aperture Efficiency

Power density 210.4 W/m2 (1.13 percentage points above 19.91% CEC median). PTC/STC ratio: 87.7% (rank #21,496).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 47.73 V at -10 C (572.8 V string) and 48.97 V at -20 C (12 max).

8 kW Reference Array

19 Panels = 8,075 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,079 W PTC; NEC 690.8 OCPD floor is 19.59 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 43.4 * (1 + (-0.285/100) * (-10 - 25)) = 47.73 V | OCPD = 1.56 * 12.56 = 19.59 A

Inputs from CEC Modules.csv for DualSun SAS DSTN425M12-B320SBB7: Voc=43.4 V, beta_Voc=-0.285%/C, Isc=12.56 A, STC=425.0 W, Area=2.02 m2.

Result: 12 panels max on 600 V (572.8 V); 19 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for DualSun SAS DSTN425M12-B320SBB7?

Official CEC datasheet figures for DualSun SAS DSTN425M12-B320SBB7 (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DSTN425M12-B320SBB7.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 425.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 372.6 W (87.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 43.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 12.56 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.0 V / 11.81 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.285 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.04% (2.02 m2) Array roof footprint density
Cell Count & Technology 32 cells (Mono-c-Si) Monofacial backsheet

How Many DualSun SAS DSTN425M12-B320SBB7 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many DualSun SAS DSTN425M12-B320SBB7 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.38 kW 326 sq ft $1,597 $2,700
8 kW Class 19 8.07 kW 413 sq ft $2,020 $3,415
10 kW Class 24 10.2 kW 522 sq ft $2,553 $4,317

How Many DualSun SAS DSTN425M12-B320SBB7 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on DualSun SAS DSTN425M12-B320SBB7 (47.73 V at 14 F).

Computed from Voc=43.4V and beta_Voc=-0.285%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 48.97 V 12 panels 587.6 V 20 panels
-10 C (14 F) 47.73 V 12 panels 572.8 V 20 panels
0 C (32 F) 46.49 V 12 panels 557.9 V 21 panels
25 C (77 F STC) 43.4 V 13 panels 564.2 V 23 panels

Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DSTN425M12-B320SBB7?

Competing CEC solar panels closest to DualSun SAS DSTN425M12-B320SBB7 in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3N-430MS.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3N-430MS
CSI Solar Co Ltd
430.0 W +5.0 W 45.7 V 21.83% 93.7%
Boviet Solar Technology Co Ltd BVM7610M-435-H-HC
Boviet Solar Technology Co Ltd
435.0 W +10.0 W 41.21 V 20.71% 94.0%
AE Solar GmbH AE420CMD-108BDE
AE Solar GmbH
420.0 W -5.0 W 39.7 V 21.54% 94.8%
CertainTeed CTM10435HC11-06
CertainTeed
435.0 W +10.0 W 40.95 V 20.14% 93.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for DualSun SAS DSTN425M12-B320SBB7?

Evaluate DualSun SAS DSTN425M12-B320SBB7 (425.0 W STC, 43.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DSTN425M12-B320SBB7 reaches 48.97 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (413 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of DualSun SAS DSTN425M12-B320SBB7 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

DualSun SAS DSTN425M12-B320SBB7 8 kW Residential Fit

Needs 19 modules (413 sq ft) with a 20 A string OCPD, offsetting ~$2,020/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 12 panels (-20 C), or compare CSI Solar Co Ltd CS3N-430MS.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 372.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DSTN425M12-B320SBB7 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

How many DualSun SAS DSTN425M12-B320SBB7 panels fit on a 600 V winter solar string?

At -10 C (14 F), DualSun SAS DSTN425M12-B320SBB7 cold Voc rises from 43.4 V to 47.73 V (beta_Voc -0.285%/C), capping a 600 V string at 12 panels (572.8 V).

How much roof area does an 8 kW array of DualSun SAS DSTN425M12-B320SBB7 need?

An 8 kW DC system uses 19 DualSun SAS DSTN425M12-B320SBB7 modules (8,075 W STC / 7,079 W PTC), covering roughly 413 sq ft and saving ~$2,020/yr at 18.54 c/kWh.

How does DualSun SAS DSTN425M12-B320SBB7 compare against CSI Solar Co Ltd CS3N-430MS?

DualSun SAS DSTN425M12-B320SBB7 outputs 425.0 W STC (43.4 V Voc, rank #7,622 of 21,677), while CSI Solar Co Ltd CS3N-430MS delivers 430.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.