DualSun SAS DualSun 360M-120-01 is a 360.0 W STC (335.5 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 40.9 V Voc at 25 C, and 44.74 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 335.5 W
- Voc @ 25C
- 40.9 V
- Efficiency
- 19.89%
How Does DualSun SAS DualSun 360M-120-01 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for DualSun SAS DualSun 360M-120-01 (Mono-c-Si) residential solar systems.
Homeowners evaluating DualSun SAS DualSun 360M-120-01 need 17 panels for 6 kW or 23 panels (448 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft). Under NEC 690.7(A), beta_Voc (-0.268%/C) pushes open-circuit voltage to 44.74 V at 14 F and 45.83 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does DualSun SAS DualSun 360M-120-01 Fall Across Listed CEC Models?
Comparison of DualSun SAS DualSun 360M-120-01 (360.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.
What Dataset Percentiles Define DualSun SAS DualSun 360M-120-01?
Relative ranking of DualSun SAS DualSun 360M-120-01 across nameplate watts, 93.2% PTC thermal ratio, and module aperture efficiency.
What Do the Dataset Ranks Show for DualSun SAS DualSun 360M-120-01?
Summary of DualSun SAS DualSun 360M-120-01 output rank, 8 kW array size (23 panels), efficiency rating, and 600 V string limit.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.89% Aperture Efficiency
Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.74 V at -10 C (581.6 V string) and 45.83 V at -20 C (13 max).
23 Panels = 8,280 W STC
Occupies 41.6 m2 (448 sq ft) producing 7,716 W PTC; NEC 690.8 OCPD floor is 17.47 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.9 * (1 + (-0.268/100) * (-10 - 25)) = 44.74 V | OCPD = 1.56 * 11.2 = 17.47 A
Inputs from CEC Modules.csv for DualSun SAS DualSun 360M-120-01: Voc=40.9 V, beta_Voc=-0.268%/C, Isc=11.2 A, STC=360.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (581.6 V); 23 panels for 8 kW (448 sq ft).
What Are the Published CEC Specifications for DualSun SAS DualSun 360M-120-01?
Complete CEC test sheet for DualSun SAS DualSun 360M-120-01 including Isc (11.2 A), Voc (40.9 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 335.5 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.2 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.7 V / 10.69 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.268 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.89% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many DualSun SAS DualSun 360M-120-01 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using DualSun SAS DualSun 360M-120-01.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 331 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 448 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 546 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?
Related DualSun SAS power steps and black/silver trims consolidated into this DualSun SAS DualSun 360M-120-01 series guide.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| DualSun SAS DualSun 350M-120-01 | 350.0 W | 326.0 W | 40.5 V | 33.3 V | 19.34% |
| DualSun SAS DualSun 355M-120-01 | 355.0 W | 330.8 W | 40.7 V | 33.5 V | 19.61% |
| DualSun SAS DualSun 360M-120-01 | 360.0 W | 335.5 W | 40.9 V | 33.7 V | 19.89% |
| DualSun SAS DualSun 365M-120-01 | 365.0 W | 340.3 W | 41.1 V | 33.9 V | 20.17% |
| DualSun SAS DualSun 370M-120-01 | 370.0 W | 345.1 W | 41.3 V | 34.1 V | 20.44% |
How Many DualSun SAS DualSun 360M-120-01 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for DualSun SAS DualSun 360M-120-01 (40.9 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.83 V | 13 panels | 595.8 V | 21 panels |
| -10 C (14 F) | 44.74 V | 13 panels | 581.6 V | 22 panels |
| 0 C (32 F) | 43.64 V | 13 panels | 567.3 V | 22 panels |
| 25 C (77 F STC) | 40.9 V | 14 panels | 572.6 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 360M-120-01?
Four comparable CEC modules such as CSI Solar Co Ltd CS3L-360P (360.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-360P CSI Solar Co Ltd |
360.0 W | Tie (0 W) | 40.6 V | 20.11% | 92.4% |
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| AXITEC AC-360MH/120V AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| AXITEC AC-360MH/120VB AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |
What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 360M-120-01?
Evaluate DualSun SAS DualSun 360M-120-01 (360.0 W STC, 40.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 360M-120-01 reaches 45.83 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
- 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 360M-120-01 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
DualSun SAS DualSun 360M-120-01 8 kW Residential Fit
Needs 23 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360P.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for DualSun SAS DualSun 360M-120-01 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.
Why is DualSun SAS DualSun 360M-120-01 PTC wattage (335.5 W) lower than STC (360.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 335.5 W PTC (93.2% retention) across DualSun SAS DualSun 360M-120-01's 1.81 m2 aperture.
Who should skip DualSun SAS DualSun 360M-120-01 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 DualSun SAS DualSun 360M-120-01 panels (448 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3L-360P.
What is the 1,000 V commercial string limit for DualSun SAS DualSun 360M-120-01?
On 1,000 V commercial inverters at -10 C (44.74 V cold Voc), DualSun SAS DualSun 360M-120-01 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting DualSun SAS DualSun 360M-120-01.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)