AXITEC AC-360MH/120V is a 360.0 W STC (332.2 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 40.5 V Voc at 25 C, and 44.45 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 332.2 W
- Voc @ 25C
- 40.5 V
- Efficiency
- 19.89%
How Does AXITEC AC-360MH/120V Compare Against Peer CEC Listings?
Engineering position of AXITEC AC-360MH/120V (360.0 W STC) vs. Apollo Renewables Inc Apollo-M660BH-360BB across 5,889 CEC Mono-c-Si solar modules.
Ranking #12,385 across 21,677 CEC solar panels (below all-CEC median; higher than 41.3% of peers), AXITEC AC-360MH/120V operates as a compact residential or specialty off-grid module sitting 50.0 W below the 410.0 W Mono-c-Si median. Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), 23 panels occupy 448 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-360MH/120V Fall Across Listed CEC Models?
Plots AXITEC AC-360MH/120V at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define AXITEC AC-360MH/120V?
Benchmarks AXITEC AC-360MH/120V on STC wattage, thermal PTC/STC retention, and 19.89 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for AXITEC AC-360MH/120V?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-360MH/120V by AXITEC.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.89% Aperture Efficiency
Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.45 V at -10 C (577.9 V string) and 45.58 V at -20 C (13 max).
23 Panels = 8,280 W STC
Occupies 41.6 m2 (448 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.5 * (1 + (-0.279/100) * (-10 - 25)) = 44.45 V | OCPD = 1.56 * 11.35 = 17.71 A
Inputs from CEC Modules.csv for AXITEC AC-360MH/120V: Voc=40.5 V, beta_Voc=-0.279%/C, Isc=11.35 A, STC=360.0 W, Area=1.81 m2.
Result: 13 panels max on 600 V (577.9 V); 23 panels for 8 kW (448 sq ft).
What Are the Published CEC Specifications for AXITEC AC-360MH/120V?
Laboratory test ratings recorded for AXITEC AC-360MH/120V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 332.2 W (92.3% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.5 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 34.0 V / 10.59 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.279 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.89% (1.81 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-360MH/120V Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (448 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-360MH/120V.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 331 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 448 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 546 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Sibling wattage bins and frame colors grouped with AXITEC AC-360MH/120V under AXITEC to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-350MH/120V | 350.0 W | 322.7 W | 40.1 V | 33.6 V | 19.34% |
| AXITEC AC-355MH/120V | 355.0 W | 327.5 W | 40.3 V | 33.8 V | 19.61% |
| AXITEC AC-360MH/120V | 360.0 W | 332.2 W | 40.5 V | 34.0 V | 19.89% |
| AXITEC AC-365MH/120V | 365.0 W | 337.0 W | 40.7 V | 34.2 V | 20.17% |
| AXITEC AC-370MH/120V | 370.0 W | 341.7 W | 40.9 V | 34.4 V | 20.44% |
How Many AXITEC AC-360MH/120V Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for AXITEC AC-360MH/120V (beta_Voc -0.279%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 45.58 V | 13 panels | 592.5 V | 21 panels |
| -10 C (14 F) | 44.45 V | 13 panels | 577.9 V | 22 panels |
| 0 C (32 F) | 43.32 V | 13 panels | 563.2 V | 23 panels |
| 25 C (77 F STC) | 40.5 V | 14 panels | 567.0 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-360MH/120V?
Closest cross-brand CEC competitors to AXITEC AC-360MH/120V matched near 360.0 W STC and 40.5 V Voc, led by Apollo Renewables Inc Apollo-M660BH-360BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W Dehui Solar Power (Vietnam) CoLtd |
360.0 W | Tie (0 W) | 40.5 V | 19.67% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760F 360W Dehui Solar Power (Vietnam) CoLtd |
360.0 W | Tie (0 W) | 40.5 V | 20.22% | 92.5% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760W 360W Dehui Solar Power (Vietnam) CoLtd |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-360MH/120V?
Evaluate AXITEC AC-360MH/120V (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-360MH/120V reaches 45.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-360MH/120V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-360MH/120V 8 kW Residential Fit
Needs 23 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.2 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-360MH/120V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
How many AXITEC AC-360MH/120V panels fit on a 600 V winter solar string?
At -10 C (14 F), AXITEC AC-360MH/120V cold Voc rises from 40.5 V to 44.45 V (beta_Voc -0.279%/C), capping a 600 V string at 13 panels (577.9 V).
How much roof area does an 8 kW array of AXITEC AC-360MH/120V need?
An 8 kW DC system uses 23 AXITEC AC-360MH/120V modules (8,280 W STC / 7,641 W PTC), covering roughly 448 sq ft and saving ~$2,072/yr at 18.54 c/kWh.
How does AXITEC AC-360MH/120V compare against Apollo Renewables Inc Apollo-M660BH-360BB?
AXITEC AC-360MH/120V outputs 360.0 W STC (40.5 V Voc, rank #12,385 of 21,677), while Apollo Renewables Inc Apollo-M660BH-360BB delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)