Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-360MH/120V is a 360.0 W STC (332.2 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 40.5 V Voc at 25 C, and 44.45 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
332.2 W
Voc @ 25C
40.5 V
Efficiency
19.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-360MH/120V Compare Against Peer CEC Listings?

Engineering position of AXITEC AC-360MH/120V (360.0 W STC) vs. Apollo Renewables Inc Apollo-M660BH-360BB across 5,889 CEC Mono-c-Si solar modules.

Ranking #12,385 across 21,677 CEC solar panels (below all-CEC median; higher than 41.3% of peers), AXITEC AC-360MH/120V operates as a compact residential or specialty off-grid module sitting 50.0 W below the 410.0 W Mono-c-Si median. Mid-range 40.5 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F. With strong 92.3% PTC-to-STC heat retention (#13,268 of 21,677), 23 panels occupy 448 sq ft and offset roughly $2,072/yr at average US rates (or $3,504/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does AXITEC AC-360MH/120V Fall Across Listed CEC Models?

Plots AXITEC AC-360MH/120V at 360.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-360MH/120V (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-360MH/12: 360.0 W

What Dataset Percentiles Define AXITEC AC-360MH/120V?

Benchmarks AXITEC AC-360MH/120V on STC wattage, thermal PTC/STC retention, and 19.89 aperture conversion efficiency against CEC peers.

AXITEC AC-360MH/120V Engineering BenchmarksPercentile comparison of AXITEC AC-360MH/120V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention92.3%Module Efficiency19.89%

What Do the Dataset Ranks Show for AXITEC AC-360MH/120V?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for AXITEC AC-360MH/120V by AXITEC.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 92.3% (rank #13,268).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.45 V at -10 C (577.9 V string) and 45.58 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,641 W PTC; NEC 690.8 OCPD floor is 17.71 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.5 * (1 + (-0.279/100) * (-10 - 25)) = 44.45 V | OCPD = 1.56 * 11.35 = 17.71 A

Inputs from CEC Modules.csv for AXITEC AC-360MH/120V: Voc=40.5 V, beta_Voc=-0.279%/C, Isc=11.35 A, STC=360.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (577.9 V); 23 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for AXITEC AC-360MH/120V?

Laboratory test ratings recorded for AXITEC AC-360MH/120V (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-360MH/120V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 332.2 W (92.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.5 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.35 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.0 V / 10.59 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.279 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.89% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many AXITEC AC-360MH/120V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (448 sq ft at 8 kW), and estimated Year-1 electric bill offset for AXITEC AC-360MH/120V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 331 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 448 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 546 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Sibling wattage bins and frame colors grouped with AXITEC AC-360MH/120V under AXITEC to prevent duplicate spec pages.

Sibling CEC listings grouped into the AXITEC AC-360MH/120V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-350MH/120V 350.0 W 322.7 W 40.1 V 33.6 V 19.34%
AXITEC AC-355MH/120V 355.0 W 327.5 W 40.3 V 33.8 V 19.61%
AXITEC AC-360MH/120V 360.0 W 332.2 W 40.5 V 34.0 V 19.89%
AXITEC AC-365MH/120V 365.0 W 337.0 W 40.7 V 34.2 V 20.17%
AXITEC AC-370MH/120V 370.0 W 341.7 W 40.9 V 34.4 V 20.44%

How Many AXITEC AC-360MH/120V Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for AXITEC AC-360MH/120V (beta_Voc -0.279%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=40.5V and beta_Voc=-0.279%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.58 V 13 panels 592.5 V 21 panels
-10 C (14 F) 44.45 V 13 panels 577.9 V 22 panels
0 C (32 F) 43.32 V 13 panels 563.2 V 23 panels
25 C (77 F STC) 40.5 V 14 panels 567.0 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-360MH/120V?

Closest cross-brand CEC competitors to AXITEC AC-360MH/120V matched near 360.0 W STC and 40.5 V Voc, led by Apollo Renewables Inc Apollo-M660BH-360BB.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W
Dehui Solar Power (Vietnam) CoLtd
360.0 W Tie (0 W) 40.5 V 19.67% 93.3%
Dehui Solar Power (Vietnam) CoLtd DH-M760F 360W
Dehui Solar Power (Vietnam) CoLtd
360.0 W Tie (0 W) 40.5 V 20.22% 92.5%
Dehui Solar Power (Vietnam) CoLtd DH-M760W 360W
Dehui Solar Power (Vietnam) CoLtd
360.0 W Tie (0 W) 40.5 V 19.89% 92.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-360MH/120V?

Evaluate AXITEC AC-360MH/120V (360.0 W STC, 40.5 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-360MH/120V reaches 45.58 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-360MH/120V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-360MH/120V 8 kW Residential Fit

Needs 23 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.2 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-360MH/120V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

How many AXITEC AC-360MH/120V panels fit on a 600 V winter solar string?

At -10 C (14 F), AXITEC AC-360MH/120V cold Voc rises from 40.5 V to 44.45 V (beta_Voc -0.279%/C), capping a 600 V string at 13 panels (577.9 V).

How much roof area does an 8 kW array of AXITEC AC-360MH/120V need?

An 8 kW DC system uses 23 AXITEC AC-360MH/120V modules (8,280 W STC / 7,641 W PTC), covering roughly 448 sq ft and saving ~$2,072/yr at 18.54 c/kWh.

How does AXITEC AC-360MH/120V compare against Apollo Renewables Inc Apollo-M660BH-360BB?

AXITEC AC-360MH/120V outputs 360.0 W STC (40.5 V Voc, rank #12,385 of 21,677), while Apollo Renewables Inc Apollo-M660BH-360BB delivers 360.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.