Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-555MBT/144V — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-555MBT/144V is a 555.0 W STC (519.5 W PTC) Mono-c-Si solar module ranking #2,550 of 21,677 CEC listings (top 12.6%; higher than 87.4% of peers). It delivers 21.68% efficiency, 50.05 V Voc at 25 C, and 55.08 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
555.0 W
PTC Wattage
519.5 W
Voc @ 25C
50.05 V
Efficiency
21.68%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-555MBT/144V Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-555MBT/144V (Mono-c-Si) residential solar systems.

Homeowners evaluating AXITEC AC-555MBT/144V need 11 panels for 6 kW or 15 panels (413 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.287%/C) pushes open-circuit voltage to 55.08 V at 14 F and 56.51 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does AXITEC AC-555MBT/144V Fall Across Listed CEC Models?

Comparison of AXITEC AC-555MBT/144V (555.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-555MBT/144V (555.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-555MBT/1: 555.0 W

What Dataset Percentiles Define AXITEC AC-555MBT/144V?

Relative ranking of AXITEC AC-555MBT/144V across nameplate watts, 93.6% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

AXITEC AC-555MBT/144V Engineering BenchmarksPercentile comparison of AXITEC AC-555MBT/144V wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage555.0 WPTC/STC Retention93.6%Module Efficiency21.68%

What Do the Dataset Ranks Show for AXITEC AC-555MBT/144V?

Summary of AXITEC AC-555MBT/144V output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #2,550 / 21,677

Top 12.6% STC Output

555.0 W STC (+170.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #3,913

21.68% Aperture Efficiency

Power density 216.8 W/m2 (1.77 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.08 V at -10 C (550.8 V string) and 56.51 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,325 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,792 W PTC; NEC 690.8 OCPD floor is 21.95 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 50.05 * (1 + (-0.287/100) * (-10 - 25)) = 55.08 V | OCPD = 1.56 * 14.07 = 21.95 A

Inputs from CEC Modules.csv for AXITEC AC-555MBT/144V: Voc=50.05 V, beta_Voc=-0.287%/C, Isc=14.07 A, STC=555.0 W, Area=2.56 m2.

Result: 10 panels max on 600 V (550.8 V); 15 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for AXITEC AC-555MBT/144V?

Complete CEC test sheet for AXITEC AC-555MBT/144V including Isc (14.07 A), Voc (50.05 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-555MBT/144V.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 555.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 519.5 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 50.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 14.07 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.11 V / 13.18 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.287 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.68% (2.56 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many AXITEC AC-555MBT/144V Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-555MBT/144V.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 11 6.11 kW 303 sq ft $1,529 $2,586
8 kW Class 15 8.32 kW 413 sq ft $2,082 $3,521
10 kW Class 19 10.54 kW 524 sq ft $2,638 $4,461

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-555MBT/144V series guide. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Sibling CEC listings grouped into the AXITEC AC-555MBT/144V wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-550MBT/144V 550.0 W 514.6 W 49.9 V 41.96 V 21.48%
AXITEC AC-555MBT/144V 555.0 W 519.5 W 50.05 V 42.11 V 21.68%

How Many AXITEC AC-555MBT/144V Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-555MBT/144V (50.05 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=50.05V and beta_Voc=-0.287%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.51 V 10 panels 565.1 V 17 panels
-10 C (14 F) 55.08 V 10 panels 550.8 V 18 panels
0 C (32 F) 53.64 V 11 panels 590.0 V 18 panels
25 C (77 F STC) 50.05 V 11 panels 550.5 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-555MBT/144V?

Four comparable CEC modules such as ELITE Solar ET-M772BH555TB (555.0 W) for side-by-side solar quote checks. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-M772BH555TB
ELITE Solar
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
ELITE Solar ET-M772BH555TW
ELITE Solar
555.0 W Tie (0 W) 50.05 V 21.68% 93.6%
G-Star Pte Ltd GSP7G72M(H)555WT
G-Star Pte Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 94.1%
GCL System Integration Technology Co Ltd GCL-M10/72GDF555
GCL System Integration Technology Co Ltd
555.0 W Tie (0 W) 50.08 V 21.68% 93.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-555MBT/144V?

Evaluate AXITEC AC-555MBT/144V (555.0 W STC, 50.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-555MBT/144V reaches 56.51 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 413 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-555MBT/144V carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-555MBT/144V 8 kW Residential Fit

Needs 15 modules (413 sq ft) with a 25 A string OCPD, offsetting ~$2,082/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare ELITE Solar ET-M772BH555TB.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 519.5 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-555MBT/144V by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-555MBT/144V PTC wattage (519.5 W) lower than STC (555.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 519.5 W PTC (93.6% retention) across AXITEC AC-555MBT/144V's 2.56 m2 aperture.

Who should skip AXITEC AC-555MBT/144V on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 AXITEC AC-555MBT/144V panels (413 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M772BH555TB.

What is the 1,000 V commercial string limit for AXITEC AC-555MBT/144V?

On 1,000 V commercial inverters at -10 C (55.08 V cold Voc), AXITEC AC-555MBT/144V fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-555MBT/144V.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.