CSI Solar Co Ltd CS3L-360P is a 360.0 W STC (332.7 W PTC) Multi-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 20.11% efficiency, 40.6 V Voc at 25 C, and 45.25 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 360.0 W
- PTC Wattage
- 332.7 W
- Voc @ 25C
- 40.6 V
- Efficiency
- 20.11%
How Does CSI Solar Co Ltd CS3L-360P Compare Against Peer CEC Listings?
How CSI Solar Co Ltd CSI Solar Co Ltd CS3L-360P handles rooftop heat (332.7 W PTC), 8 kW sizing, and cold winter string voltage.
For NEC string engineering, CSI Solar Co Ltd CS3L-360P exhibits 11.37 A short-circuit current, requiring a 17.74 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #12,385 of 21,677 (81.2 W above the 278.8 W Multi-c-Si median), this compact residential or specialty off-grid module covers 41.2 m2 for an 8 kW system (28 panels for 10 kW). Mid-range 40.6 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.
Where Does CSI Solar Co Ltd CS3L-360P Fall Across Listed CEC Models?
Where CSI Solar Co Ltd CS3L-360P (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3L-360P?
Percentile placement of CSI Solar Co Ltd CS3L-360P across power density (201.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3L-360P?
Four critical engineering numbers homeowners and solar installers check first when reviewing CSI Solar Co Ltd CS3L-360P specifications.
360.0 W STC · Higher Than 41.3%
360.0 W STC (-25.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
20.11% Aperture Efficiency
Power density 201.1 W/m2 (0.20 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 45.25 V at -10 C (588.2 V string) and 46.57 V at -20 C (12 max).
23 Panels = 8,280 W STC
Occupies 41.2 m2 (443 sq ft) producing 7,652 W PTC; NEC 690.8 OCPD floor is 17.74 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 40.6 * (1 + (-0.327/100) * (-10 - 25)) = 45.25 V | OCPD = 1.56 * 11.37 = 17.74 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3L-360P: Voc=40.6 V, beta_Voc=-0.327%/C, Isc=11.37 A, STC=360.0 W, Area=1.79 m2.
Result: 13 panels max on 600 V (588.2 V); 23 panels for 8 kW (443 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3L-360P?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for CSI Solar Co Ltd CS3L-360P.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 360.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 332.7 W (92.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 40.6 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.37 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.4 V / 10.78 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.327 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.11% (1.79 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3L-360P Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using CSI Solar Co Ltd CS3L-360P (360.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 17 | 6.12 kW | 328 sq ft | $1,532 | $2,590 |
| 8 kW Class | 23 | 8.28 kW | 443 sq ft | $2,072 | $3,504 |
| 10 kW Class | 28 | 10.08 kW | 539 sq ft | $2,523 | $4,266 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
All closely matched CSI Solar Co Ltd wattages and cosmetic trims sharing the CSI Solar Co Ltd CS3L-360P architecture.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-350P | 350.0 W | 326.4 W | 40.2 V | 33.0 V | 19.55% |
| CSI Solar Co Ltd CS3L-355P | 355.0 W | 331.2 W | 40.4 V | 33.2 V | 19.83% |
| CSI Solar Co Ltd CS3L-360P | 360.0 W | 332.7 W | 40.6 V | 33.4 V | 20.11% |
| CSI Solar Co Ltd CS3L-365P | 365.0 W | 340.8 W | 40.8 V | 33.6 V | 20.39% |
| CSI Solar Co Ltd CS3L-370P | 370.0 W | 342.2 W | 41.0 V | 33.8 V | 20.67% |
How Many CSI Solar Co Ltd CS3L-360P Modules Fit in a Cold-Weather String?
Maximum series module counts for CSI Solar Co Ltd CS3L-360P from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.57 V | 12 panels | 558.8 V | 21 panels |
| -10 C (14 F) | 45.25 V | 13 panels | 588.2 V | 22 panels |
| 0 C (32 F) | 43.92 V | 13 panels | 571.0 V | 22 panels |
| 25 C (77 F STC) | 40.6 V | 14 panels | 568.4 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3L-360P?
Alternative CEC solar modules from competing brands near CSI Solar Co Ltd CS3L-360P (360.0 W), including Apollo Renewables Inc Apollo-M660BH-360BB.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Apollo Renewables Inc Apollo-M660BH-360BB Apollo Renewables Inc |
360.0 W | Tie (0 W) | 40.5 V | 20.0% | 93.6% |
| AXITEC AC-360MH/120V AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 92.3% |
| AXITEC AC-360MH/120VB AXITEC |
360.0 W | Tie (0 W) | 40.5 V | 19.89% | 93.3% |
| Dehui Solar Power (Vietnam) CoLtd DH-M760B 360W Dehui Solar Power (Vietnam) CoLtd |
360.0 W | Tie (0 W) | 40.5 V | 19.67% | 93.3% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3L-360P?
Evaluate CSI Solar Co Ltd CS3L-360P (360.0 W STC, 40.6 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3L-360P reaches 46.57 V per panel—exceeding 12 panels in series voids 600 V inverter warranties.
- Footprint constraint: 23 panels for an 8 kW build require 443 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (443 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3L-360P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3L-360P 8 kW Residential Fit
Needs 23 modules (443 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 12 panels (-20 C), or compare Apollo Renewables Inc Apollo-M660BH-360BB.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 332.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3L-360P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
Why is CSI Solar Co Ltd CS3L-360P PTC wattage (332.7 W) lower than STC (360.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 332.7 W PTC (92.4% retention) across CSI Solar Co Ltd CS3L-360P's 1.79 m2 aperture.
Who should skip CSI Solar Co Ltd CS3L-360P on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 23 CSI Solar Co Ltd CS3L-360P panels (443 sq ft) leave unusable roof gaps vs. Apollo Renewables Inc Apollo-M660BH-360BB.
What is the 1,000 V commercial string limit for CSI Solar Co Ltd CS3L-360P?
On 1,000 V commercial inverters at -10 C (45.25 V cold Voc), CSI Solar Co Ltd CS3L-360P fits up to 22 panels per series string.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)