Skip to main content
WireAndSun
Calculators
CEC PV Module

DualSun SAS DualSun 360M-120-00 — CEC Solar Module Specifications

Manufacturer: DualSun SAS Registry: CEC Verified Engineering Specification

DualSun SAS DualSun 360M-120-00 is a 360.0 W STC (335.9 W PTC) Mono-c-Si solar module ranking #12,385 of 21,677 CEC listings (below all-CEC median; higher than 41.3% of peers). It delivers 19.89% efficiency, 40.9 V Voc at 25 C, and 44.75 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
360.0 W
PTC Wattage
335.9 W
Voc @ 25C
40.9 V
Efficiency
19.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does DualSun SAS DualSun 360M-120-00 Compare Against Peer CEC Listings?

How DualSun SAS DualSun SAS DualSun 360M-120-00 handles rooftop heat (335.9 W PTC), 8 kW sizing, and cold winter string voltage.

DualSun SAS builds the DualSun SAS DualSun 360M-120-00 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). Compared against CSI Solar Co Ltd CS3L-360P (360.0 W), this model holds strong 93.3% PTC-to-STC heat retention (#8,323 of 21,677). Mid-range 40.9 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F, while NEC 690.8 sets a 17.47 A overcurrent floor served by a 20 A breaker.

Where Does DualSun SAS DualSun 360M-120-00 Fall Across Listed CEC Models?

Where DualSun SAS DualSun 360M-120-00 (360.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where DualSun SAS DualSun 360M-120-00 (360.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCDualSun SAS DualSu: 360.0 W

What Dataset Percentiles Define DualSun SAS DualSun 360M-120-00?

Percentile placement of DualSun SAS DualSun 360M-120-00 across power density (198.9 W/m2), thermal retention, and nameplate STC wattage.

DualSun SAS DualSun 360M-120-00 Engineering BenchmarksPercentile comparison of DualSun SAS DualSun 360M-120-00 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage360.0 WPTC/STC Retention93.3%Module Efficiency19.89%

What Do the Dataset Ranks Show for DualSun SAS DualSun 360M-120-00?

Four critical engineering numbers homeowners and solar installers check first when reviewing DualSun SAS DualSun 360M-120-00 specifications. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Rank #12,385 / 21,677

360.0 W STC · Higher Than 41.3%

360.0 W STC (-25.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #10,917

19.89% Aperture Efficiency

Power density 198.9 W/m2 (0.02 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 44.75 V at -10 C (581.8 V string) and 45.85 V at -20 C (13 max).

8 kW Reference Array

23 Panels = 8,280 W STC

Occupies 41.6 m2 (448 sq ft) producing 7,726 W PTC; NEC 690.8 OCPD floor is 17.47 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.9 * (1 + (-0.269/100) * (-10 - 25)) = 44.75 V | OCPD = 1.56 * 11.2 = 17.47 A

Inputs from CEC Modules.csv for DualSun SAS DualSun 360M-120-00: Voc=40.9 V, beta_Voc=-0.269%/C, Isc=11.2 A, STC=360.0 W, Area=1.81 m2.

Result: 13 panels max on 600 V (581.8 V); 23 panels for 8 kW (448 sq ft).

What Are the Published CEC Specifications for DualSun SAS DualSun 360M-120-00?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for DualSun SAS DualSun 360M-120-00.

Official California Energy Commission (NREL SAM) test parameters for DualSun SAS DualSun 360M-120-00.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 360.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 335.9 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.2 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 33.7 V / 10.69 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.269 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.89% (1.81 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many DualSun SAS DualSun 360M-120-00 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using DualSun SAS DualSun 360M-120-00 (360.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 17 6.12 kW 331 sq ft $1,532 $2,590
8 kW Class 23 8.28 kW 448 sq ft $2,072 $3,504
10 kW Class 28 10.08 kW 546 sq ft $2,523 $4,266

Which Sibling Wattage & Trim Variants Belong to This DualSun SAS Series?

All closely matched DualSun SAS wattages and cosmetic trims sharing the DualSun SAS DualSun 360M-120-00 architecture. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the DualSun SAS DualSun 360M-120-00 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
DualSun SAS DualSun 350M-120-00 350.0 W 326.3 W 40.5 V 33.3 V 19.34%
DualSun SAS DualSun 355M-120-00 355.0 W 331.1 W 40.7 V 33.5 V 19.61%
DualSun SAS DualSun 360M-120-00 360.0 W 335.9 W 40.9 V 33.7 V 19.89%
DualSun SAS DualSun 365M-120-00 365.0 W 340.7 W 41.1 V 33.9 V 20.17%

How Many DualSun SAS DualSun 360M-120-00 Modules Fit in a Cold-Weather String?

Maximum series module counts for DualSun SAS DualSun 360M-120-00 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.9V and beta_Voc=-0.269%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.85 V 13 panels 596.1 V 21 panels
-10 C (14 F) 44.75 V 13 panels 581.8 V 22 panels
0 C (32 F) 43.65 V 13 panels 567.4 V 22 panels
25 C (77 F STC) 40.9 V 14 panels 572.6 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to DualSun SAS DualSun 360M-120-00?

Alternative CEC solar modules from competing brands near DualSun SAS DualSun 360M-120-00 (360.0 W), including CSI Solar Co Ltd CS3L-360P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3L-360P
CSI Solar Co Ltd
360.0 W Tie (0 W) 40.6 V 20.11% 92.4%
Apollo Renewables Inc Apollo-M660BH-360BB
Apollo Renewables Inc
360.0 W Tie (0 W) 40.5 V 20.0% 93.6%
AXITEC AC-360MH/120V
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 92.3%
AXITEC AC-360MH/120VB
AXITEC
360.0 W Tie (0 W) 40.5 V 19.89% 93.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for DualSun SAS DualSun 360M-120-00?

Evaluate DualSun SAS DualSun 360M-120-00 (360.0 W STC, 40.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), DualSun SAS DualSun 360M-120-00 reaches 45.85 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 448 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (448 sq ft).
  • 2026 tax credit baseline: cash residential installs of DualSun SAS DualSun 360M-120-00 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

DualSun SAS DualSun 360M-120-00 8 kW Residential Fit

Needs 23 modules (448 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-360P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 335.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for DualSun SAS DualSun 360M-120-00 by DualSun SAS grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for DualSun SAS DualSun 360M-120-00?

Multiplying DualSun SAS DualSun 360M-120-00's 11.2 A short-circuit current by 1.56 equals 17.47 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can DualSun SAS DualSun 360M-120-00 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 44.75 V cold Voc at 14 F and handles 11.2 A Isc; string inverters cap DualSun SAS DualSun 360M-120-00 at 13 panels on 600 V.

Is DualSun SAS DualSun 360M-120-00 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of DualSun SAS DualSun 360M-120-00 rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.