Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M310 is a 310.0 W STC (274.1 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.88% efficiency, 45.4 V Voc at 25 C, and 50.9 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
274.1 W
Voc @ 25C
45.4 V
Efficiency
15.88%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M310 Compare Against Peer CEC Listings?

How Heliene Heliene 72M310 handles rooftop heat (274.1 W PTC), 8 kW sizing, and cold winter string voltage.

Heliene builds the Heliene 72M310 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 158.8 W/m2 (4.03 percentage points below 19.91% CEC median). Compared against Chinaland Solar Energy HSE310-72M (310.0 W), this model holds typical 88.4% PTC-to-STC thermal output (274.1 W real-world rating). Mid-range 45.4 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 13.88 A overcurrent floor served by a 15 A breaker.

Where Does Heliene 72M310 Fall Across Listed CEC Models?

Where Heliene 72M310 (310.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M310: 310.0 W

What Dataset Percentiles Define Heliene 72M310?

Percentile placement of Heliene 72M310 across power density (158.8 W/m2), thermal retention, and nameplate STC wattage. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Heliene 72M310 Engineering BenchmarksPercentile comparison of Heliene 72M310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention88.4%Module Efficiency15.88%

What Do the Dataset Ranks Show for Heliene 72M310?

Four critical engineering numbers homeowners and solar installers check first when reviewing Heliene 72M310 specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,341

15.88% Aperture Efficiency

Power density 158.8 W/m2 (4.03 percentage points below 19.91% CEC median). PTC/STC ratio: 88.4% (rank #21,190).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.9 V at -10 C (559.9 V string) and 52.47 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.8 m2 (546 sq ft) producing 7,127 W PTC; NEC 690.8 OCPD floor is 13.88 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.4 * (1 + (-0.346/100) * (-10 - 25)) = 50.9 V | OCPD = 1.56 * 8.9 = 13.88 A

Inputs from CEC Modules.csv for Heliene 72M310: Voc=45.4 V, beta_Voc=-0.346%/C, Isc=8.9 A, STC=310.0 W, Area=1.952 m2.

Result: 11 panels max on 600 V (559.9 V); 26 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for Heliene 72M310?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Heliene 72M310. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 274.1 W (88.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.4 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.9 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.77 V / 8.43 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.346 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.88% (1.952 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Heliene 72M310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Heliene 72M310 (310.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 420 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 546 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 693 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

All closely matched Heliene wattages and cosmetic trims sharing the Heliene 72M310 architecture. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 72M310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72M300 300.0 W 269.4 W 44.96 V 36.55 V 15.37%
Heliene 72M305 305.0 W 269.5 W 45.1 V 36.65 V 15.62%
Heliene 72M310 310.0 W 274.1 W 45.4 V 36.77 V 15.88%
Heliene 72M315 315.0 W 279.6 W 45.31 V 37.19 V 17.14%
Heliene 72M320 320.0 W 284.2 W 45.69 V 37.48 V 17.41%

How Many Heliene 72M310 Modules Fit in a Cold-Weather String?

Maximum series module counts for Heliene 72M310 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=45.4V and beta_Voc=-0.346%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.47 V 11 panels 577.2 V 19 panels
-10 C (14 F) 50.9 V 11 panels 559.9 V 19 panels
0 C (32 F) 49.33 V 12 panels 592.0 V 20 panels
25 C (77 F STC) 45.4 V 13 panels 590.2 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M310?

Alternative CEC solar modules from competing brands near Heliene 72M310 (310.0 W), including Chinaland Solar Energy HSE310-72M. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Chinaland Solar Energy HSE310-72M
Chinaland Solar Energy
310.0 W Tie (0 W) 45.4 V 16.06% 90.3%
GCL System Integration Technology Co Ltd GCL-P6/72310
GCL System Integration Technology Co Ltd
310.0 W Tie (0 W) 45.4 V 15.98% 90.5%
AXITEC AC-310M/156-72S
AXITEC
310.0 W Tie (0 W) 45.49 V 16.01% 90.2%
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M310?

Evaluate Heliene 72M310 (310.0 W STC, 45.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M310 reaches 52.47 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of Heliene 72M310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M310 8 kW Residential Fit

Needs 26 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE310-72M.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 274.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M310 by Heliene grounded in CEC test data and NEC 690.7/690.8 limits. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

What fuse or breaker size does NEC 690.8 require for Heliene 72M310?

Multiplying Heliene 72M310's 8.9 A short-circuit current by 1.56 equals 13.88 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker. Check local building department permit requirements for Heliene 72M310 before finalizing component orders.

Can Heliene 72M310 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 50.9 V cold Voc at 14 F and handles 8.9 A Isc; string inverters cap Heliene 72M310 at 11 panels on 600 V.

Is Heliene 72M310 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Heliene 72M310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.