Advance Power API-P310 is a 310.0 W STC (277.3 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.89% efficiency, 45.22 V Voc at 25 C, and 50.51 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 277.3 W
- Voc @ 25C
- 45.22 V
- Efficiency
- 15.89%
How Does Advance Power API-P310 Compare Against Peer CEC Listings?
Engineering position of Advance Power API-P310 (310.0 W STC) vs. Auxin Solar AXN6P612T310 across 1,407 CEC Multi-c-Si solar modules.
Built with 72 Multi-c-Si cells, Advance Power API-P310 pairs typical 89.5% PTC-to-STC thermal output (277.3 W real-world rating) with 45.22 V nominal Voc. An 8 kW residential build (8,060 W DC, 7,210 W PTC) saves ~$2,017/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6P612T310 offers a 310.0 W alternative.
Where Does Advance Power API-P310 Fall Across Listed CEC Models?
Plots Advance Power API-P310 at 310.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Advance Power API-P310?
Benchmarks Advance Power API-P310 on STC wattage, thermal PTC/STC retention, and 15.89 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Advance Power API-P310?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Advance Power API-P310 by Advance Power.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
15.89% Aperture Efficiency
Power density 158.9 W/m2 (4.02 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.51 V at -10 C (555.6 V string) and 52.02 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.7 m2 (546 sq ft) producing 7,210 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.22 * (1 + (-0.334/100) * (-10 - 25)) = 50.51 V | OCPD = 1.56 * 8.62 = 13.45 A
Inputs from CEC Modules.csv for Advance Power API-P310: Voc=45.22 V, beta_Voc=-0.334%/C, Isc=8.62 A, STC=310.0 W, Area=1.951 m2.
Result: 11 panels max on 600 V (555.6 V); 26 panels for 8 kW (546 sq ft).
What Are the Published CEC Specifications for Advance Power API-P310?
Laboratory test ratings recorded for Advance Power API-P310 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 277.3 W (89.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.22 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 8.62 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.02 V / 8.16 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.334 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 15.89% (1.951 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many Advance Power API-P310 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (546 sq ft at 8 kW), and estimated Year-1 electric bill offset for Advance Power API-P310.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 420 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 546 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 693 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?
Sibling wattage bins and frame colors grouped with Advance Power API-P310 under Advance Power to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Advance Power API-P300 | 300.0 W | 270.7 W | 44.86 V | 37.66 V | 15.38% |
| Advance Power API-P305 | 305.0 W | 275.4 W | 45.0 V | 37.87 V | 15.63% |
| Advance Power API-P310 | 310.0 W | 277.3 W | 45.22 V | 38.02 V | 15.89% |
| Advance Power API-P315 | 315.0 W | 281.9 W | 45.58 V | 38.45 V | 16.14% |
| Advance Power API-P320 | 320.0 W | 288.7 W | 45.51 V | 36.59 V | 16.49% |
How Many Advance Power API-P310 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Advance Power API-P310 (beta_Voc -0.334%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.02 V | 11 panels | 572.2 V | 19 panels |
| -10 C (14 F) | 50.51 V | 11 panels | 555.6 V | 19 panels |
| 0 C (32 F) | 49.0 V | 12 panels | 588.0 V | 20 panels |
| 25 C (77 F STC) | 45.22 V | 13 panels | 587.9 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to Advance Power API-P310?
Closest cross-brand CEC competitors to Advance Power API-P310 matched near 310.0 W STC and 45.22 V Voc, led by Auxin Solar AXN6P612T310.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6P612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| AXITEC AC-310P/156-72S AXITEC |
310.0 W | Tie (0 W) | 45.05 V | 16.01% | 89.0% |
| Chinaland Solar Energy HSE310-72M Chinaland Solar Energy |
310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
What Are the Design Limits and Best-Fit Uses for Advance Power API-P310?
Evaluate Advance Power API-P310 (310.0 W STC, 45.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-P310 reaches 52.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft).
- 2026 tax credit baseline: cash residential installs of Advance Power API-P310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Advance Power API-P310 8 kW Residential Fit
Needs 26 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6P612T310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 277.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Advance Power API-P310 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for Advance Power API-P310?
Multiplying Advance Power API-P310's 8.62 A short-circuit current by 1.56 equals 13.45 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can Advance Power API-P310 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.51 V cold Voc at 14 F and handles 8.62 A Isc; string inverters cap Advance Power API-P310 at 11 panels on 600 V.
Is Advance Power API-P310 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Advance Power API-P310 rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)