Skip to main content
WireAndSun
Calculators
CEC PV Module

AXITEC AC-310P/156-72S — CEC Solar Module Specifications

Manufacturer: AXITEC Registry: CEC Verified Engineering Specification

AXITEC AC-310P/156-72S is a 310.0 W STC (276.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.01% efficiency, 45.05 V Voc at 25 C, and 50.41 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
276.0 W
Voc @ 25C
45.05 V
Efficiency
16.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does AXITEC AC-310P/156-72S Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-310P/156-72S (Multi-c-Si) residential solar systems.

Homeowners evaluating AXITEC AC-310P/156-72S need 20 panels for 6 kW or 26 panels (542 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 50.41 V at 14 F and 51.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does AXITEC AC-310P/156-72S Fall Across Listed CEC Models?

Comparison of AXITEC AC-310P/156-72S (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where AXITEC AC-310P/156-72S (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAXITEC AC-310P/156: 310.0 W

What Dataset Percentiles Define AXITEC AC-310P/156-72S?

Relative ranking of AXITEC AC-310P/156-72S across nameplate watts, 89.0% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

AXITEC AC-310P/156-72S Engineering BenchmarksPercentile comparison of AXITEC AC-310P/156-72S wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention89.0%Module Efficiency16.01%

What Do the Dataset Ranks Show for AXITEC AC-310P/156-72S?

Summary of AXITEC AC-310P/156-72S output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,116

16.01% Aperture Efficiency

Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.41 V at -10 C (554.5 V string) and 51.94 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.3 m2 (542 sq ft) producing 7,176 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.05 * (1 + (-0.34/100) * (-10 - 25)) = 50.41 V | OCPD = 1.56 * 9.1 = 14.2 A

Inputs from CEC Modules.csv for AXITEC AC-310P/156-72S: Voc=45.05 V, beta_Voc=-0.34%/C, Isc=9.1 A, STC=310.0 W, Area=1.936 m2.

Result: 11 panels max on 600 V (554.5 V); 26 panels for 8 kW (542 sq ft).

What Are the Published CEC Specifications for AXITEC AC-310P/156-72S?

Complete CEC test sheet for AXITEC AC-310P/156-72S including Isc (9.1 A), Voc (45.05 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for AXITEC AC-310P/156-72S.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 276.0 W (89.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.05 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.1 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.82 V / 8.42 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.34 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.01% (1.936 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many AXITEC AC-310P/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-310P/156-72S.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 417 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 542 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 688 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?

Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-310P/156-72S series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.

Sibling CEC listings grouped into the AXITEC AC-310P/156-72S wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
AXITEC AC-300P/156-72S 300.0 W 270.5 W 44.82 V 36.3 V 15.49%
AXITEC AC-305P/156-72S 305.0 W 275.1 W 44.91 V 36.61 V 15.75%
AXITEC AC-310P/156-72S 310.0 W 276.0 W 45.05 V 36.82 V 16.01%
AXITEC AC-315P/156-72S 315.0 W 280.6 W 45.16 V 37.11 V 16.27%
AXITEC AC-320P/156-72S 320.0 W 285.2 W 45.27 V 37.34 V 16.53%

How Many AXITEC AC-310P/156-72S Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for AXITEC AC-310P/156-72S (45.05 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.05V and beta_Voc=-0.34%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 51.94 V 11 panels 571.3 V 19 panels
-10 C (14 F) 50.41 V 11 panels 554.5 V 19 panels
0 C (32 F) 48.88 V 12 panels 586.6 V 20 panels
25 C (77 F STC) 45.05 V 13 panels 585.6 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-310P/156-72S?

Four comparable CEC modules such as Auxin Solar AXN6M612T310 (310.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612T310
Auxin Solar
310.0 W Tie (0 W) 45.0 V 15.89% 89.4%
Centrosolar America DP72 310
Centrosolar America
310.0 W Tie (0 W) 45.18 V 15.94% 90.2%
CSI Solar Co Ltd CS6X-310P
CSI Solar Co Ltd
310.0 W Tie (0 W) 44.9 V 16.31% 91.4%
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for AXITEC AC-310P/156-72S?

Evaluate AXITEC AC-310P/156-72S (310.0 W STC, 45.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-310P/156-72S reaches 51.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
  • 2026 tax credit baseline: cash residential installs of AXITEC AC-310P/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

AXITEC AC-310P/156-72S 8 kW Residential Fit

Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 276.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for AXITEC AC-310P/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is AXITEC AC-310P/156-72S PTC wattage (276.0 W) lower than STC (310.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 276.0 W PTC (89.0% retention) across AXITEC AC-310P/156-72S's 1.936 m2 aperture.

Who should skip AXITEC AC-310P/156-72S on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 AXITEC AC-310P/156-72S panels (542 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612T310.

What is the 1,000 V commercial string limit for AXITEC AC-310P/156-72S?

On 1,000 V commercial inverters at -10 C (50.41 V cold Voc), AXITEC AC-310P/156-72S fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-310P/156-72S.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.