AXITEC AC-310P/156-72S is a 310.0 W STC (276.0 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.01% efficiency, 45.05 V Voc at 25 C, and 50.41 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 276.0 W
- Voc @ 25C
- 45.05 V
- Efficiency
- 16.01%
How Does AXITEC AC-310P/156-72S Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for AXITEC AC-310P/156-72S (Multi-c-Si) residential solar systems.
Homeowners evaluating AXITEC AC-310P/156-72S need 20 panels for 6 kW or 26 panels (542 sq ft) for an 8 kW array—useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft). Under NEC 690.7(A), beta_Voc (-0.34%/C) pushes open-circuit voltage to 50.41 V at 14 F and 51.94 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does AXITEC AC-310P/156-72S Fall Across Listed CEC Models?
Comparison of AXITEC AC-310P/156-72S (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define AXITEC AC-310P/156-72S?
Relative ranking of AXITEC AC-310P/156-72S across nameplate watts, 89.0% PTC thermal ratio, and module aperture efficiency. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
What Do the Dataset Ranks Show for AXITEC AC-310P/156-72S?
Summary of AXITEC AC-310P/156-72S output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
16.01% Aperture Efficiency
Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 89.0% (rank #20,637).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.41 V at -10 C (554.5 V string) and 51.94 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.3 m2 (542 sq ft) producing 7,176 W PTC; NEC 690.8 OCPD floor is 14.2 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.05 * (1 + (-0.34/100) * (-10 - 25)) = 50.41 V | OCPD = 1.56 * 9.1 = 14.2 A
Inputs from CEC Modules.csv for AXITEC AC-310P/156-72S: Voc=45.05 V, beta_Voc=-0.34%/C, Isc=9.1 A, STC=310.0 W, Area=1.936 m2.
Result: 11 panels max on 600 V (554.5 V); 26 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for AXITEC AC-310P/156-72S?
Complete CEC test sheet for AXITEC AC-310P/156-72S including Isc (9.1 A), Voc (45.05 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 276.0 W (89.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.05 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.1 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.82 V / 8.42 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.34 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.01% (1.936 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Multi-c-Si) | Monofacial backsheet |
How Many AXITEC AC-310P/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using AXITEC AC-310P/156-72S.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 417 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 688 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Related AXITEC power steps and black/silver trims consolidated into this AXITEC AC-310P/156-72S series guide. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-300P/156-72S | 300.0 W | 270.5 W | 44.82 V | 36.3 V | 15.49% |
| AXITEC AC-305P/156-72S | 305.0 W | 275.1 W | 44.91 V | 36.61 V | 15.75% |
| AXITEC AC-310P/156-72S | 310.0 W | 276.0 W | 45.05 V | 36.82 V | 16.01% |
| AXITEC AC-315P/156-72S | 315.0 W | 280.6 W | 45.16 V | 37.11 V | 16.27% |
| AXITEC AC-320P/156-72S | 320.0 W | 285.2 W | 45.27 V | 37.34 V | 16.53% |
How Many AXITEC AC-310P/156-72S Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for AXITEC AC-310P/156-72S (45.05 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 51.94 V | 11 panels | 571.3 V | 19 panels |
| -10 C (14 F) | 50.41 V | 11 panels | 554.5 V | 19 panels |
| 0 C (32 F) | 48.88 V | 12 panels | 586.6 V | 20 panels |
| 25 C (77 F STC) | 45.05 V | 13 panels | 585.6 V | 22 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-310P/156-72S?
Four comparable CEC modules such as Auxin Solar AXN6M612T310 (310.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612T310 Auxin Solar |
310.0 W | Tie (0 W) | 45.0 V | 15.89% | 89.4% |
| Centrosolar America DP72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.18 V | 15.94% | 90.2% |
| CSI Solar Co Ltd CS6X-310P CSI Solar Co Ltd |
310.0 W | Tie (0 W) | 44.9 V | 16.31% | 91.4% |
| Advance Power API-P310 Advance Power |
310.0 W | Tie (0 W) | 45.22 V | 15.89% | 89.5% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-310P/156-72S?
Evaluate AXITEC AC-310P/156-72S (310.0 W STC, 45.05 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-310P/156-72S reaches 51.94 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-310P/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-310P/156-72S 8 kW Residential Fit
Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T310.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 276.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-310P/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
Why is AXITEC AC-310P/156-72S PTC wattage (276.0 W) lower than STC (310.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 276.0 W PTC (89.0% retention) across AXITEC AC-310P/156-72S's 1.936 m2 aperture.
Who should skip AXITEC AC-310P/156-72S on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 26 AXITEC AC-310P/156-72S panels (542 sq ft) leave unusable roof gaps vs. Auxin Solar AXN6M612T310.
What is the 1,000 V commercial string limit for AXITEC AC-310P/156-72S?
On 1,000 V commercial inverters at -10 C (50.41 V cold Voc), AXITEC AC-310P/156-72S fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting AXITEC AC-310P/156-72S.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)