Skip to main content
WireAndSun
Calculators
CEC PV Module

Advance Power API-M340 — CEC Solar Module Specifications

Manufacturer: Advance Power Registry: CEC Verified Engineering Specification

Advance Power API-M340 is a 340.0 W STC (311.8 W PTC) Mono-c-Si solar module ranking #13,575 of 21,677 CEC listings (below all-CEC median; higher than 36.1% of peers). It delivers 17.53% efficiency, 47.18 V Voc at 25 C, and 52.13 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
340.0 W
PTC Wattage
311.8 W
Voc @ 25C
47.18 V
Efficiency
17.53%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Advance Power API-M340 Compare Against Peer CEC Listings?

Engineering position of Advance Power API-M340 (340.0 W STC) vs. DEHUI SOLAR POWER INC DH-72M-340W across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Advance Power API-M340 pairs strong 91.7% PTC-to-STC heat retention (#15,053 of 21,677) with 47.18 V nominal Voc. An 8 kW residential build (8,160 W DC, 7,483 W PTC) saves ~$2,042/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer DEHUI SOLAR POWER INC DH-72M-340W offers a 340.0 W alternative.

Where Does Advance Power API-M340 Fall Across Listed CEC Models?

Plots Advance Power API-M340 at 340.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Advance Power API-M340 (340.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAdvance Power API-: 340.0 W

What Dataset Percentiles Define Advance Power API-M340?

Benchmarks Advance Power API-M340 on STC wattage, thermal PTC/STC retention, and 17.53 aperture conversion efficiency against CEC peers.

Advance Power API-M340 Engineering BenchmarksPercentile comparison of Advance Power API-M340 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage340.0 WPTC/STC Retention91.7%Module Efficiency17.53%

What Do the Dataset Ranks Show for Advance Power API-M340?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Advance Power API-M340 by Advance Power.

Rank #13,575 / 21,677

340.0 W STC · Higher Than 36.1%

340.0 W STC (-45.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #15,724

17.53% Aperture Efficiency

Power density 175.3 W/m2 (2.38 percentage points below 19.91% CEC median). PTC/STC ratio: 91.7% (rank #15,053).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.13 V at -10 C (573.4 V string) and 53.55 V at -20 C (11 max).

8 kW Reference Array

24 Panels = 8,160 W STC

Occupies 46.6 m2 (501 sq ft) producing 7,483 W PTC; NEC 690.8 OCPD floor is 15.04 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.18 * (1 + (-0.3/100) * (-10 - 25)) = 52.13 V | OCPD = 1.56 * 9.64 = 15.04 A

Inputs from CEC Modules.csv for Advance Power API-M340: Voc=47.18 V, beta_Voc=-0.3%/C, Isc=9.64 A, STC=340.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (573.4 V); 24 panels for 8 kW (501 sq ft).

What Are the Published CEC Specifications for Advance Power API-M340?

Laboratory test ratings recorded for Advance Power API-M340 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Advance Power API-M340.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 340.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 311.8 W (91.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.18 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.64 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.32 V / 8.96 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.3 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.53% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Advance Power API-M340 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (501 sq ft at 8 kW), and estimated Year-1 electric bill offset for Advance Power API-M340.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.12 kW 376 sq ft $1,532 $2,590
8 kW Class 24 8.16 kW 501 sq ft $2,042 $3,454
10 kW Class 30 10.2 kW 626 sq ft $2,553 $4,317

Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?

Sibling wattage bins and frame colors grouped with Advance Power API-M340 under Advance Power to prevent duplicate spec pages.

Sibling CEC listings grouped into the Advance Power API-M340 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Advance Power API-M330 330.0 W 302.4 W 46.76 V 37.71 V 17.01%
Advance Power API-M335 335.0 W 307.1 W 47.04 V 37.98 V 17.27%
Advance Power API-M340 340.0 W 311.8 W 47.18 V 38.32 V 17.53%
Advance Power API-M345 345.0 W 315.8 W 47.28 V 38.4 V 17.78%

How Many Advance Power API-M340 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Advance Power API-M340 (beta_Voc -0.3%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=47.18V and beta_Voc=-0.3%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.55 V 11 panels 589.0 V 18 panels
-10 C (14 F) 52.13 V 11 panels 573.4 V 19 panels
0 C (32 F) 50.72 V 11 panels 557.9 V 19 panels
25 C (77 F STC) 47.18 V 12 panels 566.2 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Advance Power API-M340?

Closest cross-brand CEC competitors to Advance Power API-M340 matched near 340.0 W STC and 47.18 V Voc, led by DEHUI SOLAR POWER INC DH-72M-340W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
DEHUI SOLAR POWER INC DH-72M-340W
DEHUI SOLAR POWER INC
340.0 W Tie (0 W) 47.3 V 17.68% 91.3%
Anhui Rinengzhongtian Semiconductor Development Co Ltd QJM340-72
Anhui Rinengzhongtian Semiconductor Development Co Ltd
340.0 W Tie (0 W) 46.97 V 17.52% 91.0%
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-340W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
340.0 W Tie (0 W) 46.91 V 17.68% 91.4%
GCL System Integration Technology Co Ltd GCL-M6/72340
GCL System Integration Technology Co Ltd
340.0 W Tie (0 W) 46.6 V 17.53% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Advance Power API-M340?

Evaluate Advance Power API-M340 (340.0 W STC, 47.18 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-M340 reaches 53.55 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 501 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (501 sq ft).
  • 2026 tax credit baseline: cash residential installs of Advance Power API-M340 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Advance Power API-M340 8 kW Residential Fit

Needs 24 modules (501 sq ft) with a 20 A string OCPD, offsetting ~$2,042/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare DEHUI SOLAR POWER INC DH-72M-340W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 311.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Advance Power API-M340 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Advance Power API-M340?

Multiplying Advance Power API-M340's 9.64 A short-circuit current by 1.56 equals 15.04 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Advance Power API-M340 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.13 V cold Voc at 14 F and handles 9.64 A Isc; string inverters cap Advance Power API-M340 at 11 panels on 600 V.

Is Advance Power API-M340 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Advance Power API-M340 rely on utility bill offset (~$2,042/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.