Skip to main content
WireAndSun
Calculators
CEC PV Module

Advance Power API-P285 — CEC Solar Module Specifications

Manufacturer: Advance Power Registry: CEC Verified Engineering Specification

Advance Power API-P285 is a 285.0 W STC (256.9 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.61% efficiency, 44.21 V Voc at 25 C, and 49.29 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
256.9 W
Voc @ 25C
44.21 V
Efficiency
14.61%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Advance Power API-P285 Compare Against Peer CEC Listings?

Solar engineering breakdown for Advance Power API-P285: PTC thermal retention, roof footprint, and cold Voc string bounds. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Across 1,407 Multi-c-Si listings from Advance Power and peers, Advance Power API-P285 stands 6.2 W above the 278.8 W Multi-c-Si median and typical 90.1% PTC-to-STC thermal output (256.9 W real-world rating). Sizing 6 kW (22 panels) to 10 kW (36 panels) yields $1,569-$2,568/yr in baseline US bill offset. Mid-range 44.21 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F.

Where Does Advance Power API-P285 Fall Across Listed CEC Models?

Distribution marker showing Advance Power API-P285 (285.0 W) relative to the 385.0 W all-CEC solar panel median. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Advance Power API-P285 (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAdvance Power API-: 285.0 W

What Dataset Percentiles Define Advance Power API-P285?

Dataset percentiles tracking Advance Power API-P285 power output, thermal retention ratio, and aperture efficiency against 21,677 models. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Advance Power API-P285 Engineering BenchmarksPercentile comparison of Advance Power API-P285 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.1%Module Efficiency14.61%

What Do the Dataset Ranks Show for Advance Power API-P285?

Benchmark highlights for Advance Power API-P285 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,273

14.61% Aperture Efficiency

Power density 146.1 W/m2 (5.30 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.29 V at -10 C (591.5 V string) and 50.74 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.6 m2 (609 sq ft) producing 7,450 W PTC; NEC 690.8 OCPD floor is 12.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.21 * (1 + (-0.328/100) * (-10 - 25)) = 49.29 V | OCPD = 1.56 * 8.32 = 12.98 A

Inputs from CEC Modules.csv for Advance Power API-P285: Voc=44.21 V, beta_Voc=-0.328%/C, Isc=8.32 A, STC=285.0 W, Area=1.951 m2.

Result: 12 panels max on 600 V (591.5 V); 29 panels for 8 kW (609 sq ft).

What Are the Published CEC Specifications for Advance Power API-P285?

Official CEC datasheet figures for Advance Power API-P285 (Multi-c-Si) used in utility interconnection and permit reviews. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.

Official California Energy Commission (NREL SAM) test parameters for Advance Power API-P285.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.9 W (90.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.79 V / 7.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.61% (1.951 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Advance Power API-P285 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Advance Power API-P285 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 462 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 609 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 756 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Advance Power Series?

Consolidated Advance Power wattage variants sharing the Advance Power API-P285 mechanical and cell layout. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Advance Power API-P285 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Advance Power API-P275 275.0 W 245.2 W 43.92 V 36.58 V 14.09%
Advance Power API-P280 280.0 W 249.8 W 44.06 V 36.72 V 14.35%
Advance Power API-P285 285.0 W 256.9 W 44.21 V 36.79 V 14.61%
Advance Power API-P290 290.0 W 261.5 W 44.28 V 36.79 V 14.86%
Advance Power API-P295 295.0 W 266.1 W 44.42 V 37.01 V 15.12%

How Many Advance Power API-P285 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Advance Power API-P285 (49.29 V at 14 F).

Computed from Voc=44.21V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.74 V 11 panels 558.1 V 19 panels
-10 C (14 F) 49.29 V 12 panels 591.5 V 20 panels
0 C (32 F) 47.84 V 12 panels 574.1 V 20 panels
25 C (77 F STC) 44.21 V 13 panels 574.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Advance Power API-P285?

Competing CEC solar panels closest to Advance Power API-P285 in nameplate wattage and Voc, starting with Auxin Solar AXN6M612T285.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN6M612T285
Auxin Solar
285.0 W Tie (0 W) 44.21 V 14.61% 89.1%
Auxin Solar AXN6P612T285
Auxin Solar
285.0 W Tie (0 W) 44.21 V 14.61% 90.1%
Auxin Solar AXN6P612T285G
Auxin Solar
285.0 W Tie (0 W) 44.21 V 14.61% 90.1%
BYD Company Limited BYD 285P6C-36
BYD Company Limited
285.0 W Tie (0 W) 44.3 V 14.69% 91.0%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Advance Power API-P285?

Evaluate Advance Power API-P285 (285.0 W STC, 44.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Advance Power API-P285 reaches 50.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 609 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (609 sq ft).
  • 2026 tax credit baseline: cash residential installs of Advance Power API-P285 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Advance Power API-P285 8 kW Residential Fit

Needs 29 modules (609 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Advance Power API-P285 by Advance Power grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Advance Power API-P285?

Multiplying Advance Power API-P285's 8.32 A short-circuit current by 1.56 equals 12.98 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Advance Power API-P285 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.29 V cold Voc at 14 F and handles 8.32 A Isc; string inverters cap Advance Power API-P285 at 12 panels on 600 V.

Is Advance Power API-P285 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Advance Power API-P285 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.