Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6P612T285 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6P612T285 is a 285.0 W STC (256.9 W PTC) Multi-c-Si solar module ranking #17,598 of 21,677 CEC listings (below all-CEC median; higher than 17.3% of peers). It delivers 14.61% efficiency, 44.21 V Voc at 25 C, and 49.29 V cold Voc at -10 C (12 panels max per 600 V string).

STC Wattage
285.0 W
PTC Wattage
256.9 W
Voc @ 25C
44.21 V
Efficiency
14.61%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6P612T285 Compare Against Peer CEC Listings?

How Auxin Solar Auxin Solar AXN6P612T285 handles rooftop heat (256.9 W PTC), 8 kW sizing, and cold winter string voltage.

Auxin Solar builds the Auxin Solar AXN6P612T285 (Multi-c-Si) as a compact residential or specialty off-grid module delivering 146.1 W/m2 (5.30 percentage points below 19.91% CEC median). Compared against Advance Power API-M285 (285.0 W), this model holds typical 90.1% PTC-to-STC thermal output (256.9 W real-world rating). Mid-range 44.21 V open-circuit voltage allows up to 12 panels per 600 V string at 14 F, while NEC 690.8 sets a 12.98 A overcurrent floor served by a 15 A breaker.

Where Does Auxin Solar AXN6P612T285 Fall Across Listed CEC Models?

Where Auxin Solar AXN6P612T285 (285.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6P612T285 (285.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6P6: 285.0 W

What Dataset Percentiles Define Auxin Solar AXN6P612T285?

Percentile placement of Auxin Solar AXN6P612T285 across power density (146.1 W/m2), thermal retention, and nameplate STC wattage.

Auxin Solar AXN6P612T285 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6P612T285 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage285.0 WPTC/STC Retention90.1%Module Efficiency14.61%

What Do the Dataset Ranks Show for Auxin Solar AXN6P612T285?

Four critical engineering numbers homeowners and solar installers check first when reviewing Auxin Solar AXN6P612T285 specifications. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

Rank #17,598 / 21,677

285.0 W STC · Higher Than 17.3%

285.0 W STC (-100.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #20,273

14.61% Aperture Efficiency

Power density 146.1 W/m2 (5.30 percentage points below 19.91% CEC median). PTC/STC ratio: 90.1% (rank #18,772).

NEC 690.7 Limit

12 Panels Max @ -10 C (600 V)

Cold Voc reaches 49.29 V at -10 C (591.5 V string) and 50.74 V at -20 C (11 max).

8 kW Reference Array

29 Panels = 8,265 W STC

Occupies 56.6 m2 (609 sq ft) producing 7,450 W PTC; NEC 690.8 OCPD floor is 12.98 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 44.21 * (1 + (-0.328/100) * (-10 - 25)) = 49.29 V | OCPD = 1.56 * 8.32 = 12.98 A

Inputs from CEC Modules.csv for Auxin Solar AXN6P612T285: Voc=44.21 V, beta_Voc=-0.328%/C, Isc=8.32 A, STC=285.0 W, Area=1.951 m2.

Result: 12 panels max on 600 V (591.5 V); 29 panels for 8 kW (609 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6P612T285?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Auxin Solar AXN6P612T285.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6P612T285.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 285.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 256.9 W (90.1% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 44.21 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.32 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 36.79 V / 7.75 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.328 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 14.61% (1.951 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6P612T285 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Auxin Solar AXN6P612T285 (285.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 22 6.27 kW 462 sq ft $1,569 $2,654
8 kW Class 29 8.27 kW 609 sq ft $2,070 $3,500
10 kW Class 36 10.26 kW 756 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

All closely matched Auxin Solar wattages and cosmetic trims sharing the Auxin Solar AXN6P612T285 architecture. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Sibling CEC listings grouped into the Auxin Solar AXN6P612T285 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6P612T275 275.0 W 245.2 W 43.92 V 36.58 V 14.09%
Auxin Solar AXN6P612T280 280.0 W 249.8 W 44.06 V 36.72 V 14.35%
Auxin Solar AXN6P612T285 285.0 W 256.9 W 44.21 V 36.79 V 14.61%
Auxin Solar AXN6P612T290 290.0 W 261.5 W 44.28 V 36.79 V 14.86%
Auxin Solar AXN6P612T295 295.0 W 266.1 W 44.42 V 37.01 V 15.12%

How Many Auxin Solar AXN6P612T285 Modules Fit in a Cold-Weather String?

Maximum series module counts for Auxin Solar AXN6P612T285 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=44.21V and beta_Voc=-0.328%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 50.74 V 11 panels 558.1 V 19 panels
-10 C (14 F) 49.29 V 12 panels 591.5 V 20 panels
0 C (32 F) 47.84 V 12 panels 574.1 V 20 panels
25 C (77 F STC) 44.21 V 13 panels 574.7 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P612T285?

Alternative CEC solar modules from competing brands near Auxin Solar AXN6P612T285 (285.0 W), including Advance Power API-M285. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-M285
Advance Power
285.0 W Tie (0 W) 44.21 V 14.61% 89.1%
Advance Power API-P285
Advance Power
285.0 W Tie (0 W) 44.21 V 14.61% 90.1%
BYD Company Limited BYD 285P6C-36
BYD Company Limited
285.0 W Tie (0 W) 44.3 V 14.69% 91.0%
CSI Solar Co Ltd CS6X-285P
CSI Solar Co Ltd
285.0 W Tie (0 W) 44.3 V 15.39% 91.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P612T285?

Evaluate Auxin Solar AXN6P612T285 (285.0 W STC, 44.21 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P612T285 reaches 50.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 29 panels for an 8 kW build require 609 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 29 panels (609 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P612T285 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6P612T285 8 kW Residential Fit

Needs 29 modules (609 sq ft) with a 15 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 12 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-M285.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 256.9 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6P612T285 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Auxin Solar AXN6P612T285?

Multiplying Auxin Solar AXN6P612T285's 8.32 A short-circuit current by 1.56 equals 12.98 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Auxin Solar AXN6P612T285 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 49.29 V cold Voc at 14 F and handles 8.32 A Isc; string inverters cap Auxin Solar AXN6P612T285 at 12 panels on 600 V.

Is Auxin Solar AXN6P612T285 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Auxin Solar AXN6P612T285 rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.