Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN10M540W — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M540W is a 540.0 W STC (505.1 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.51% efficiency, 49.65 V Voc at 25 C, and 54.03 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
505.1 W
Voc @ 25C
49.65 V
Efficiency
21.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M540W Compare Against Peer CEC Listings?

How Auxin Solar Auxin Solar AXN10M540W handles rooftop heat (505.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Auxin Solar AXN10M540W exhibits 13.85 A short-circuit current, requiring a 21.61 A (156%) conductor rating and 25 A OCPD under NEC 690.8. Ranked #3,265 of 21,677 (130.0 W above the 410.0 W Mono-c-Si median), this large-format commercial and ground-mount module covers 37.6 m2 for an 8 kW system (19 panels for 10 kW). Higher 49.65 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C).

Where Does Auxin Solar AXN10M540W Fall Across Listed CEC Models?

Where Auxin Solar AXN10M540W (540.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M540W (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 540.0 W

What Dataset Percentiles Define Auxin Solar AXN10M540W?

Percentile placement of Auxin Solar AXN10M540W across power density (215.1 W/m2), thermal retention, and nameplate STC wattage.

Auxin Solar AXN10M540W Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M540W wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention93.5%Module Efficiency21.51%

What Do the Dataset Ranks Show for Auxin Solar AXN10M540W?

Four critical engineering numbers homeowners and solar installers check first when reviewing Auxin Solar AXN10M540W specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,356

21.51% Aperture Efficiency

Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.03 V at -10 C (594.3 V string) and 55.28 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,576 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.65 * (1 + (-0.252/100) * (-10 - 25)) = 54.03 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M540W: Voc=49.65 V, beta_Voc=-0.252%/C, Isc=13.85 A, STC=540.0 W, Area=2.51 m2.

Result: 11 panels max on 600 V (594.3 V); 15 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M540W?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Auxin Solar AXN10M540W.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M540W.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 505.1 W (93.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.65 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.252 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.51% (2.51 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M540W Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Auxin Solar AXN10M540W (540.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 324 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 405 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 513 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

All closely matched Auxin Solar wattages and cosmetic trims sharing the Auxin Solar AXN10M540W architecture. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Sibling CEC listings grouped into the Auxin Solar AXN10M540W wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M530W 530.0 W 495.5 W 49.35 V 41.35 V 21.12%
Auxin Solar AXN10M535W 535.0 W 500.3 W 49.5 V 41.5 V 21.31%
Auxin Solar AXN10M540W 540.0 W 505.1 W 49.65 V 41.65 V 21.51%
Auxin Solar AXN10M545W 545.0 W 509.9 W 49.81 V 41.82 V 21.71%

How Many Auxin Solar AXN10M540W Modules Fit in a Cold-Weather String?

Maximum series module counts for Auxin Solar AXN10M540W from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=49.65V and beta_Voc=-0.252%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.28 V 10 panels 552.8 V 18 panels
-10 C (14 F) 54.03 V 11 panels 594.3 V 18 panels
0 C (32 F) 52.78 V 11 panels 580.6 V 18 panels
25 C (77 F STC) 49.65 V 12 panels 595.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M540W?

Alternative CEC solar modules from competing brands near Auxin Solar AXN10M540W (540.0 W), including Convalt Manufacturing LLC CVLT540-144MH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Convalt Manufacturing LLC CVLT540-144MH
Convalt Manufacturing LLC
540.0 W Tie (0 W) 49.65 V 21.26% 92.5%
AMPS Solar AMPS-540P-72BB
AMPS Solar
540.0 W Tie (0 W) 49.6 V 21.09% 94.3%
AXITEC AC-540MH/144V
AXITEC
540.0 W Tie (0 W) 49.6 V 21.09% 93.6%
ELITE Solar ET-M772BH540WB
ELITE Solar
540.0 W Tie (0 W) 49.6 V 21.09% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M540W?

Evaluate Auxin Solar AXN10M540W (540.0 W STC, 49.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M540W reaches 55.28 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 405 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M540W carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M540W 8 kW Residential Fit

Needs 15 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Convalt Manufacturing LLC CVLT540-144MH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 505.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M540W by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Auxin Solar AXN10M540W PTC wattage (505.1 W) lower than STC (540.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 505.1 W PTC (93.5% retention) across Auxin Solar AXN10M540W's 2.51 m2 aperture.

Who should skip Auxin Solar AXN10M540W on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Auxin Solar AXN10M540W panels (405 sq ft) leave unusable roof gaps vs. Convalt Manufacturing LLC CVLT540-144MH.

What is the 1,000 V commercial string limit for Auxin Solar AXN10M540W?

On 1,000 V commercial inverters at -10 C (54.03 V cold Voc), Auxin Solar AXN10M540W fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Auxin Solar AXN10M540W.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.