Convalt Manufacturing LLC CVLT540-144MH — CEC Solar Module Specifications

Manufacturer: Convalt Manufacturing LLC Registry: CEC Verified Engineering Specification

Convalt Manufacturing LLC CVLT540-144MH is a 540.0 W STC (499.4 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.26% efficiency, 49.65 V Voc at 25 C, and 54.74 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
499.4 W
Voc @ 25C
49.65 V
Efficiency
21.26%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Convalt Manufacturing LLC CVLT540-144MH Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Convalt Manufacturing LLC CVLT540-144MH (Mono-c-Si) residential solar systems.

Homeowners evaluating Convalt Manufacturing LLC CVLT540-144MH need 12 panels for 6 kW or 15 panels (410 sq ft) for an 8 kW array—better matched to wide open ground racks or commercial flat roofs than tight residential roof hips. Under NEC 690.7(A), beta_Voc (-0.293%/C) pushes open-circuit voltage to 54.74 V at 14 F and 56.2 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Convalt Manufacturing LLC CVLT540-144MH Fall Across Listed CEC Models?

Comparison of Convalt Manufacturing LLC CVLT540-144MH (540.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Convalt Manufacturing LLC CVLT540-144MH (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCConvalt Manufactur: 540.0 W

What Dataset Percentiles Define Convalt Manufacturing LLC CVLT540-144MH?

Relative ranking of Convalt Manufacturing LLC CVLT540-144MH across nameplate watts, 92.5% PTC thermal ratio, and module aperture efficiency.

Convalt Manufacturing LLC CVLT540-144MH Engineering BenchmarksPercentile comparison of Convalt Manufacturing LLC CVLT540-144MH wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention92.5%Module Efficiency21.26%

What Do the Dataset Ranks Show for Convalt Manufacturing LLC CVLT540-144MH?

Summary of Convalt Manufacturing LLC CVLT540-144MH output rank, 8 kW array size (15 panels), efficiency rating, and 600 V string limit.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,361

21.26% Aperture Efficiency

Power density 212.6 W/m2 (1.35 percentage points above 19.91% CEC median). PTC/STC ratio: 92.5% (rank #12,531).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.74 V at -10 C (547.4 V string) and 56.2 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 38.1 m2 (410 sq ft) producing 7,491 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.65 * (1 + (-0.293/100) * (-10 - 25)) = 54.74 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for Convalt Manufacturing LLC CVLT540-144MH: Voc=49.65 V, beta_Voc=-0.293%/C, Isc=13.85 A, STC=540.0 W, Area=2.54 m2.

Result: 10 panels max on 600 V (547.4 V); 15 panels for 8 kW (410 sq ft).

What Are the Published CEC Specifications for Convalt Manufacturing LLC CVLT540-144MH?

Complete CEC test sheet for Convalt Manufacturing LLC CVLT540-144MH including Isc (13.85 A), Voc (49.65 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Convalt Manufacturing LLC CVLT540-144MH.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 499.4 W (92.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.65 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.293 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.26% (2.54 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Convalt Manufacturing LLC CVLT540-144MH Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Convalt Manufacturing LLC CVLT540-144MH.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 328 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 410 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 519 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Convalt Manufacturing LLC Series?

Related Convalt Manufacturing LLC power steps and black/silver trims consolidated into this Convalt Manufacturing LLC CVLT540-144MH series guide.

Sibling CEC listings grouped into the Convalt Manufacturing LLC CVLT540-144MH wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Convalt Manufacturing LLC CVLT535-144MH 535.0 W 494.6 W 49.5 V 41.5 V 21.06%
Convalt Manufacturing LLC CVLT540-144MH 540.0 W 499.4 W 49.65 V 41.65 V 21.26%
Convalt Manufacturing LLC CVLT545-144MH 545.0 W 504.2 W 49.81 V 41.8 V 21.46%

How Many Convalt Manufacturing LLC CVLT540-144MH Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Convalt Manufacturing LLC CVLT540-144MH (49.65 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=49.65V and beta_Voc=-0.293%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 56.2 V 10 panels 562.0 V 17 panels
-10 C (14 F) 54.74 V 10 panels 547.4 V 18 panels
0 C (32 F) 53.29 V 11 panels 586.2 V 18 panels
25 C (77 F STC) 49.65 V 12 panels 595.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Convalt Manufacturing LLC CVLT540-144MH?

Four comparable CEC modules such as Auxin Solar AXN10M540B (540.0 W) for side-by-side solar quote checks. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Auxin Solar AXN10M540B
Auxin Solar
540.0 W Tie (0 W) 49.65 V 21.51% 94.0%
Auxin Solar AXN10M540W
Auxin Solar
540.0 W Tie (0 W) 49.65 V 21.51% 93.5%
AMPS Solar AMPS-540P-72BB
AMPS Solar
540.0 W Tie (0 W) 49.6 V 21.09% 94.3%
AXITEC AC-540MH/144V
AXITEC
540.0 W Tie (0 W) 49.6 V 21.09% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Convalt Manufacturing LLC CVLT540-144MH?

Evaluate Convalt Manufacturing LLC CVLT540-144MH (540.0 W STC, 49.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Convalt Manufacturing LLC CVLT540-144MH reaches 56.2 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 410 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Convalt Manufacturing LLC CVLT540-144MH carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Convalt Manufacturing LLC CVLT540-144MH 8 kW Residential Fit

Needs 15 modules (410 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare Auxin Solar AXN10M540B.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 499.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Convalt Manufacturing LLC CVLT540-144MH by Convalt Manufacturing LLC grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Convalt Manufacturing LLC CVLT540-144MH PTC wattage (499.4 W) lower than STC (540.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 499.4 W PTC (92.5% retention) across Convalt Manufacturing LLC CVLT540-144MH's 2.54 m2 aperture.

Who should skip Convalt Manufacturing LLC CVLT540-144MH on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 15 Convalt Manufacturing LLC CVLT540-144MH panels (410 sq ft) leave unusable roof gaps vs. Auxin Solar AXN10M540B.

What is the 1,000 V commercial string limit for Convalt Manufacturing LLC CVLT540-144MH?

On 1,000 V commercial inverters at -10 C (54.74 V cold Voc), Convalt Manufacturing LLC CVLT540-144MH fits up to 18 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Convalt Manufacturing LLC CVLT540-144MH.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.