Auxin Solar AXN10M540B is a 540.0 W STC (507.6 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.51% efficiency, 49.65 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 540.0 W
- PTC Wattage
- 507.6 W
- Voc @ 25C
- 49.65 V
- Efficiency
- 21.51%
How Does Auxin Solar AXN10M540B Compare Against Peer CEC Listings?
Engineering position of Auxin Solar AXN10M540B (540.0 W STC) vs. Convalt Manufacturing LLC CVLT540-144MH across 5,889 CEC Mono-c-Si solar modules.
Ranking #3,265 across 21,677 CEC solar panels (top 16.3%; higher than 83.7% of peers), Auxin Solar AXN10M540B operates as a large-format commercial and ground-mount module sitting 130.0 W above the 410.0 W Mono-c-Si median. Higher 49.65 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), 15 panels occupy 405 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does Auxin Solar AXN10M540B Fall Across Listed CEC Models?
Plots Auxin Solar AXN10M540B at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Auxin Solar AXN10M540B?
Benchmarks Auxin Solar AXN10M540B on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Auxin Solar AXN10M540B?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN10M540B by Auxin Solar.
Top 16.3% STC Output
540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.51% Aperture Efficiency
Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.1 V at -20 C (10 max).
15 Panels = 8,100 W STC
Occupies 37.6 m2 (405 sq ft) producing 7,614 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.65 * (1 + (-0.244/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 13.85 = 21.61 A
Inputs from CEC Modules.csv for Auxin Solar AXN10M540B: Voc=49.65 V, beta_Voc=-0.244%/C, Isc=13.85 A, STC=540.0 W, Area=2.51 m2.
Result: 11 panels max on 600 V (592.8 V); 15 panels for 8 kW (405 sq ft).
What Are the Published CEC Specifications for Auxin Solar AXN10M540B?
Laboratory test ratings recorded for Auxin Solar AXN10M540B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 540.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 507.6 W (94.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.65 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.85 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.65 V / 12.97 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.244 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.51% (2.51 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Auxin Solar AXN10M540B Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN10M540B.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 12 | 6.48 kW | 324 sq ft | $1,622 | $2,742 |
| 8 kW Class | 15 | 8.1 kW | 405 sq ft | $2,027 | $3,428 |
| 10 kW Class | 19 | 10.26 kW | 513 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?
Sibling wattage bins and frame colors grouped with Auxin Solar AXN10M540B under Auxin Solar to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Auxin Solar AXN10M530B | 530.0 W | 498.0 W | 49.35 V | 41.35 V | 21.12% |
| Auxin Solar AXN10M535B | 535.0 W | 502.8 W | 49.5 V | 41.5 V | 21.31% |
| Auxin Solar AXN10M540B | 540.0 W | 507.6 W | 49.65 V | 41.65 V | 21.51% |
| Auxin Solar AXN10M545B | 545.0 W | 512.5 W | 49.81 V | 41.82 V | 21.71% |
How Many Auxin Solar AXN10M540B Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Auxin Solar AXN10M540B (beta_Voc -0.244%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.1 V | 10 panels | 551.0 V | 18 panels |
| -10 C (14 F) | 53.89 V | 11 panels | 592.8 V | 18 panels |
| 0 C (32 F) | 52.68 V | 11 panels | 579.5 V | 18 panels |
| 25 C (77 F STC) | 49.65 V | 12 panels | 595.8 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M540B?
Closest cross-brand CEC competitors to Auxin Solar AXN10M540B matched near 540.0 W STC and 49.65 V Voc, led by Convalt Manufacturing LLC CVLT540-144MH.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Convalt Manufacturing LLC CVLT540-144MH Convalt Manufacturing LLC |
540.0 W | Tie (0 W) | 49.65 V | 21.26% | 92.5% |
| AMPS Solar AMPS-540P-72BB AMPS Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 94.3% |
| AXITEC AC-540MH/144V AXITEC |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.6% |
| ELITE Solar ET-M772BH540WB ELITE Solar |
540.0 W | Tie (0 W) | 49.6 V | 21.09% | 93.6% |
What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M540B?
Evaluate Auxin Solar AXN10M540B (540.0 W STC, 49.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M540B reaches 55.1 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 15 panels for an 8 kW build require 405 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
- 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M540B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Auxin Solar AXN10M540B 8 kW Residential Fit
Needs 15 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Convalt Manufacturing LLC CVLT540-144MH.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 507.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Auxin Solar AXN10M540B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.
How many Auxin Solar AXN10M540B panels fit on a 600 V winter solar string?
At -10 C (14 F), Auxin Solar AXN10M540B cold Voc rises from 49.65 V to 53.89 V (beta_Voc -0.244%/C), capping a 600 V string at 11 panels (592.8 V).
How much roof area does an 8 kW array of Auxin Solar AXN10M540B need?
An 8 kW DC system uses 15 Auxin Solar AXN10M540B modules (8,100 W STC / 7,614 W PTC), covering roughly 405 sq ft and saving ~$2,027/yr at 18.54 c/kWh.
How does Auxin Solar AXN10M540B compare against Convalt Manufacturing LLC CVLT540-144MH?
Auxin Solar AXN10M540B outputs 540.0 W STC (49.65 V Voc, rank #3,265 of 21,677), while Convalt Manufacturing LLC CVLT540-144MH delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)