Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN10M540B — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN10M540B is a 540.0 W STC (507.6 W PTC) Mono-c-Si solar module ranking #3,265 of 21,677 CEC listings (top 16.3%; higher than 83.7% of peers). It delivers 21.51% efficiency, 49.65 V Voc at 25 C, and 53.89 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
540.0 W
PTC Wattage
507.6 W
Voc @ 25C
49.65 V
Efficiency
21.51%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN10M540B Compare Against Peer CEC Listings?

Engineering position of Auxin Solar AXN10M540B (540.0 W STC) vs. Convalt Manufacturing LLC CVLT540-144MH across 5,889 CEC Mono-c-Si solar modules.

Ranking #3,265 across 21,677 CEC solar panels (top 16.3%; higher than 83.7% of peers), Auxin Solar AXN10M540B operates as a large-format commercial and ground-mount module sitting 130.0 W above the 410.0 W Mono-c-Si median. Higher 49.65 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 94.0% PTC-to-STC heat retention (#4,745 of 21,677), 15 panels occupy 405 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Monofacial backsheet sealing targets flush dark shingle rooftop mounts.

Where Does Auxin Solar AXN10M540B Fall Across Listed CEC Models?

Plots Auxin Solar AXN10M540B at 540.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN10M540B (540.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN10M: 540.0 W

What Dataset Percentiles Define Auxin Solar AXN10M540B?

Benchmarks Auxin Solar AXN10M540B on STC wattage, thermal PTC/STC retention, and 21.51 aperture conversion efficiency against CEC peers.

Auxin Solar AXN10M540B Engineering BenchmarksPercentile comparison of Auxin Solar AXN10M540B wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage540.0 WPTC/STC Retention94.0%Module Efficiency21.51%

What Do the Dataset Ranks Show for Auxin Solar AXN10M540B?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Auxin Solar AXN10M540B by Auxin Solar.

Rank #3,265 / 21,677

Top 16.3% STC Output

540.0 W STC (+155.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,356

21.51% Aperture Efficiency

Power density 215.1 W/m2 (1.60 percentage points above 19.91% CEC median). PTC/STC ratio: 94.0% (rank #4,745).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.89 V at -10 C (592.8 V string) and 55.1 V at -20 C (10 max).

8 kW Reference Array

15 Panels = 8,100 W STC

Occupies 37.6 m2 (405 sq ft) producing 7,614 W PTC; NEC 690.8 OCPD floor is 21.61 A (25 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.65 * (1 + (-0.244/100) * (-10 - 25)) = 53.89 V | OCPD = 1.56 * 13.85 = 21.61 A

Inputs from CEC Modules.csv for Auxin Solar AXN10M540B: Voc=49.65 V, beta_Voc=-0.244%/C, Isc=13.85 A, STC=540.0 W, Area=2.51 m2.

Result: 11 panels max on 600 V (592.8 V); 15 panels for 8 kW (405 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN10M540B?

Laboratory test ratings recorded for Auxin Solar AXN10M540B (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN10M540B.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 540.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 507.6 W (94.0% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.65 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 13.85 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.65 V / 12.97 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.244 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.51% (2.51 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Auxin Solar AXN10M540B Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (405 sq ft at 8 kW), and estimated Year-1 electric bill offset for Auxin Solar AXN10M540B.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 12 6.48 kW 324 sq ft $1,622 $2,742
8 kW Class 15 8.1 kW 405 sq ft $2,027 $3,428
10 kW Class 19 10.26 kW 513 sq ft $2,568 $4,342

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Sibling wattage bins and frame colors grouped with Auxin Solar AXN10M540B under Auxin Solar to prevent duplicate spec pages.

Sibling CEC listings grouped into the Auxin Solar AXN10M540B wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN10M530B 530.0 W 498.0 W 49.35 V 41.35 V 21.12%
Auxin Solar AXN10M535B 535.0 W 502.8 W 49.5 V 41.5 V 21.31%
Auxin Solar AXN10M540B 540.0 W 507.6 W 49.65 V 41.65 V 21.51%
Auxin Solar AXN10M545B 545.0 W 512.5 W 49.81 V 41.82 V 21.71%

How Many Auxin Solar AXN10M540B Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Auxin Solar AXN10M540B (beta_Voc -0.244%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.65V and beta_Voc=-0.244%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.1 V 10 panels 551.0 V 18 panels
-10 C (14 F) 53.89 V 11 panels 592.8 V 18 panels
0 C (32 F) 52.68 V 11 panels 579.5 V 18 panels
25 C (77 F STC) 49.65 V 12 panels 595.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN10M540B?

Closest cross-brand CEC competitors to Auxin Solar AXN10M540B matched near 540.0 W STC and 49.65 V Voc, led by Convalt Manufacturing LLC CVLT540-144MH.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Convalt Manufacturing LLC CVLT540-144MH
Convalt Manufacturing LLC
540.0 W Tie (0 W) 49.65 V 21.26% 92.5%
AMPS Solar AMPS-540P-72BB
AMPS Solar
540.0 W Tie (0 W) 49.6 V 21.09% 94.3%
AXITEC AC-540MH/144V
AXITEC
540.0 W Tie (0 W) 49.6 V 21.09% 93.6%
ELITE Solar ET-M772BH540WB
ELITE Solar
540.0 W Tie (0 W) 49.6 V 21.09% 93.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN10M540B?

Evaluate Auxin Solar AXN10M540B (540.0 W STC, 49.65 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN10M540B reaches 55.1 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 15 panels for an 8 kW build require 405 sq ft of unshaded roof plane — better matched to wide open ground racks or commercial flat roofs than tight residential roof hips.
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN10M540B carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN10M540B 8 kW Residential Fit

Needs 15 modules (405 sq ft) with a 25 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Convalt Manufacturing LLC CVLT540-144MH.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 507.6 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN10M540B by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN10M540B panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN10M540B cold Voc rises from 49.65 V to 53.89 V (beta_Voc -0.244%/C), capping a 600 V string at 11 panels (592.8 V).

How much roof area does an 8 kW array of Auxin Solar AXN10M540B need?

An 8 kW DC system uses 15 Auxin Solar AXN10M540B modules (8,100 W STC / 7,614 W PTC), covering roughly 405 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Auxin Solar AXN10M540B compare against Convalt Manufacturing LLC CVLT540-144MH?

Auxin Solar AXN10M540B outputs 540.0 W STC (49.65 V Voc, rank #3,265 of 21,677), while Convalt Manufacturing LLC CVLT540-144MH delivers 540.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.