Skip to main content
WireAndSun
Calculators
CEC PV Module

Auxin Solar AXN6P612T310 — CEC Solar Module Specifications

Manufacturer: Auxin Solar Registry: CEC Verified Engineering Specification

Auxin Solar AXN6P612T310 is a 310.0 W STC (277.3 W PTC) Multi-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.89% efficiency, 45.22 V Voc at 25 C, and 50.51 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
277.3 W
Voc @ 25C
45.22 V
Efficiency
15.89%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Auxin Solar AXN6P612T310 Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Auxin Solar AXN6P612T310 (Multi-c-Si) residential solar systems.

Auxin Solar AXN6P612T310 delivers 158.9 W/m2 (4.02 percentage points below 19.91% CEC median) and typical 89.5% PTC-to-STC thermal output (277.3 W real-world rating), placing it as a compact residential or specialty off-grid module useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft). At -4 F (-20 C), string voltage climbs to 52.02 V per unit, capping 600 V circuits at 11 panels. Compare specs directly with Advance Power API-P310 (310.0 W).

Where Does Auxin Solar AXN6P612T310 Fall Across Listed CEC Models?

Comparison of Auxin Solar AXN6P612T310 (310.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Auxin Solar AXN6P612T310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCAuxin Solar AXN6P6: 310.0 W

What Dataset Percentiles Define Auxin Solar AXN6P612T310?

Relative ranking of Auxin Solar AXN6P612T310 across nameplate watts, 89.5% PTC thermal ratio, and module aperture efficiency. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

Auxin Solar AXN6P612T310 Engineering BenchmarksPercentile comparison of Auxin Solar AXN6P612T310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention89.5%Module Efficiency15.89%

What Do the Dataset Ranks Show for Auxin Solar AXN6P612T310?

Summary of Auxin Solar AXN6P612T310 output rank, 8 kW array size (26 panels), efficiency rating, and 600 V string limit.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #18,318

15.89% Aperture Efficiency

Power density 158.9 W/m2 (4.02 percentage points below 19.91% CEC median). PTC/STC ratio: 89.5% (rank #19,939).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.51 V at -10 C (555.6 V string) and 52.02 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.7 m2 (546 sq ft) producing 7,210 W PTC; NEC 690.8 OCPD floor is 13.45 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.22 * (1 + (-0.334/100) * (-10 - 25)) = 50.51 V | OCPD = 1.56 * 8.62 = 13.45 A

Inputs from CEC Modules.csv for Auxin Solar AXN6P612T310: Voc=45.22 V, beta_Voc=-0.334%/C, Isc=8.62 A, STC=310.0 W, Area=1.951 m2.

Result: 11 panels max on 600 V (555.6 V); 26 panels for 8 kW (546 sq ft).

What Are the Published CEC Specifications for Auxin Solar AXN6P612T310?

Complete CEC test sheet for Auxin Solar AXN6P612T310 including Isc (8.62 A), Voc (45.22 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Auxin Solar AXN6P612T310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 277.3 W (89.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.22 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.62 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.02 V / 8.16 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.334 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.89% (1.951 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many Auxin Solar AXN6P612T310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Auxin Solar AXN6P612T310.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 420 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 546 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 693 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Auxin Solar Series?

Related Auxin Solar power steps and black/silver trims consolidated into this Auxin Solar AXN6P612T310 series guide. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Sibling CEC listings grouped into the Auxin Solar AXN6P612T310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Auxin Solar AXN6P612T300 300.0 W 270.7 W 44.86 V 37.66 V 15.38%
Auxin Solar AXN6P612T305 305.0 W 275.4 W 45.0 V 37.87 V 15.63%
Auxin Solar AXN6P612T310 310.0 W 277.3 W 45.22 V 38.02 V 15.89%
Auxin Solar AXN6P612T315 315.0 W 281.9 W 45.58 V 38.45 V 16.14%
Auxin Solar AXN6P612T320 320.0 W 288.7 W 45.51 V 36.59 V 16.49%

How Many Auxin Solar AXN6P612T310 Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Auxin Solar AXN6P612T310 (45.22 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=45.22V and beta_Voc=-0.334%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.02 V 11 panels 572.2 V 19 panels
-10 C (14 F) 50.51 V 11 panels 555.6 V 19 panels
0 C (32 F) 49.0 V 12 panels 588.0 V 20 panels
25 C (77 F STC) 45.22 V 13 panels 587.9 V 22 panels

Which Cross-Brand Solar Modules Compare Closest to Auxin Solar AXN6P612T310?

Four comparable CEC modules such as Advance Power API-P310 (310.0 W) for side-by-side solar quote checks. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Advance Power API-P310
Advance Power
310.0 W Tie (0 W) 45.22 V 15.89% 89.5%
Centrosolar America DP72 310
Centrosolar America
310.0 W Tie (0 W) 45.18 V 15.94% 90.2%
AXITEC AC-310P/156-72S
AXITEC
310.0 W Tie (0 W) 45.05 V 16.01% 89.0%
Chinaland Solar Energy HSE310-72M
Chinaland Solar Energy
310.0 W Tie (0 W) 45.4 V 16.06% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Auxin Solar AXN6P612T310?

Evaluate Auxin Solar AXN6P612T310 (310.0 W STC, 45.22 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Auxin Solar AXN6P612T310 reaches 52.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 546 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (546 sq ft).
  • 2026 tax credit baseline: cash residential installs of Auxin Solar AXN6P612T310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Auxin Solar AXN6P612T310 8 kW Residential Fit

Needs 26 modules (546 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Advance Power API-P310.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 277.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Auxin Solar AXN6P612T310 by Auxin Solar grounded in CEC test data and NEC 690.7/690.8 limits.

How many Auxin Solar AXN6P612T310 panels fit on a 600 V winter solar string?

At -10 C (14 F), Auxin Solar AXN6P612T310 cold Voc rises from 45.22 V to 50.51 V (beta_Voc -0.334%/C), capping a 600 V string at 11 panels (555.6 V).

How much roof area does an 8 kW array of Auxin Solar AXN6P612T310 need?

An 8 kW DC system uses 26 Auxin Solar AXN6P612T310 modules (8,060 W STC / 7,210 W PTC), covering roughly 546 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Auxin Solar AXN6P612T310 compare against Advance Power API-P310?

Auxin Solar AXN6P612T310 outputs 310.0 W STC (45.22 V Voc, rank #15,760 of 21,677), while Advance Power API-P310 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.