AXITEC AC-310M/156-72S is a 310.0 W STC (279.7 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 16.01% efficiency, 45.49 V Voc at 25 C, and 50.63 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 310.0 W
- PTC Wattage
- 279.7 W
- Voc @ 25C
- 45.49 V
- Efficiency
- 16.01%
How Does AXITEC AC-310M/156-72S Compare Against Peer CEC Listings?
Solar engineering breakdown for AXITEC AC-310M/156-72S: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Across 5,889 Mono-c-Si listings from AXITEC and peers, AXITEC AC-310M/156-72S stands 100.0 W below the 410.0 W Mono-c-Si median and typical 90.2% PTC-to-STC thermal output (279.7 W real-world rating). Sizing 6 kW (20 panels) to 10 kW (33 panels) yields $1,552-$2,560/yr in baseline US bill offset. Mid-range 45.49 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.
Where Does AXITEC AC-310M/156-72S Fall Across Listed CEC Models?
Distribution marker showing AXITEC AC-310M/156-72S (310.0 W) relative to the 385.0 W all-CEC solar panel median. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
What Dataset Percentiles Define AXITEC AC-310M/156-72S?
Dataset percentiles tracking AXITEC AC-310M/156-72S power output, thermal retention ratio, and aperture efficiency against 21,677 models. Published percentiles compare local state, county, metro, and certified equipment metrics against nationwide residential electrical baselines.
What Do the Dataset Ranks Show for AXITEC AC-310M/156-72S?
Benchmark highlights for AXITEC AC-310M/156-72S covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
310.0 W STC · Higher Than 25.6%
310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
16.01% Aperture Efficiency
Power density 160.1 W/m2 (3.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.2% (rank #18,532).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 50.63 V at -10 C (556.9 V string) and 52.1 V at -20 C (11 max).
26 Panels = 8,060 W STC
Occupies 50.3 m2 (542 sq ft) producing 7,272 W PTC; NEC 690.8 OCPD floor is 14.06 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 45.49 * (1 + (-0.323/100) * (-10 - 25)) = 50.63 V | OCPD = 1.56 * 9.01 = 14.06 A
Inputs from CEC Modules.csv for AXITEC AC-310M/156-72S: Voc=45.49 V, beta_Voc=-0.323%/C, Isc=9.01 A, STC=310.0 W, Area=1.936 m2.
Result: 11 panels max on 600 V (556.9 V); 26 panels for 8 kW (542 sq ft).
What Are the Published CEC Specifications for AXITEC AC-310M/156-72S?
Official CEC datasheet figures for AXITEC AC-310M/156-72S (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 310.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 279.7 W (90.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 45.49 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.01 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 36.84 V / 8.41 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.323 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 16.01% (1.936 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many AXITEC AC-310M/156-72S Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many AXITEC AC-310M/156-72S modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 20 | 6.2 kW | 417 sq ft | $1,552 | $2,624 |
| 8 kW Class | 26 | 8.06 kW | 542 sq ft | $2,017 | $3,411 |
| 10 kW Class | 33 | 10.23 kW | 688 sq ft | $2,560 | $4,330 |
Which Sibling Wattage & Trim Variants Belong to This AXITEC Series?
Consolidated AXITEC wattage variants sharing the AXITEC AC-310M/156-72S mechanical and cell layout. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| AXITEC AC-300M/156-72S | 300.0 W | 270.4 W | 45.11 V | 36.6 V | 15.49% |
| AXITEC AC-305M/156-72S | 305.0 W | 275.0 W | 45.28 V | 36.72 V | 15.75% |
| AXITEC AC-310M/156-72S | 310.0 W | 279.7 W | 45.49 V | 36.84 V | 16.01% |
| AXITEC AC-315M/156-72S | 315.0 W | 284.3 W | 45.62 V | 36.91 V | 16.27% |
How Many AXITEC AC-310M/156-72S Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on AXITEC AC-310M/156-72S (50.63 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 52.1 V | 11 panels | 573.1 V | 19 panels |
| -10 C (14 F) | 50.63 V | 11 panels | 556.9 V | 19 panels |
| 0 C (32 F) | 49.16 V | 12 panels | 589.9 V | 20 panels |
| 25 C (77 F STC) | 45.49 V | 13 panels | 591.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to AXITEC AC-310M/156-72S?
Competing CEC solar panels closest to AXITEC AC-310M/156-72S in nameplate wattage and Voc, starting with Chinaland Solar Energy HSE310-72M.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Chinaland Solar Energy HSE310-72M Chinaland Solar Energy |
310.0 W | Tie (0 W) | 45.4 V | 16.06% | 90.3% |
| GCL System Integration Technology Co Ltd GCL-P6/72310 GCL System Integration Technology Co Ltd |
310.0 W | Tie (0 W) | 45.4 V | 15.98% | 90.5% |
| DEHUI SOLAR POWER INC DH-72P-310W DEHUI SOLAR POWER INC |
310.0 W | Tie (0 W) | 45.6 V | 16.12% | 90.5% |
| Centrosolar America DM72 310 Centrosolar America |
310.0 W | Tie (0 W) | 45.7 V | 15.94% | 90.8% |
What Are the Design Limits and Best-Fit Uses for AXITEC AC-310M/156-72S?
Evaluate AXITEC AC-310M/156-72S (310.0 W STC, 45.49 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), AXITEC AC-310M/156-72S reaches 52.1 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 26 panels for an 8 kW build require 542 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (542 sq ft).
- 2026 tax credit baseline: cash residential installs of AXITEC AC-310M/156-72S carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
AXITEC AC-310M/156-72S 8 kW Residential Fit
Needs 26 modules (542 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Chinaland Solar Energy HSE310-72M.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 279.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for AXITEC AC-310M/156-72S by AXITEC grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for AXITEC AC-310M/156-72S?
Multiplying AXITEC AC-310M/156-72S's 9.01 A short-circuit current by 1.56 equals 14.06 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can AXITEC AC-310M/156-72S pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 50.63 V cold Voc at 14 F and handles 9.01 A Isc; string inverters cap AXITEC AC-310M/156-72S at 11 panels on 600 V.
Is AXITEC AC-310M/156-72S eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of AXITEC AC-310M/156-72S rely on utility bill offset (~$2,017/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)