Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DM72 310 is a 310.0 W STC (281.4 W PTC) Mono-c-Si solar module ranking #15,760 of 21,677 CEC listings (below all-CEC median; higher than 25.6% of peers). It delivers 15.94% efficiency, 45.7 V Voc at 25 C, and 50.88 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
310.0 W
PTC Wattage
281.4 W
Voc @ 25C
45.7 V
Efficiency
15.94%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DM72 310 Compare Against Peer CEC Listings?

Solar engineering breakdown for Centrosolar America DM72 310: PTC thermal retention, roof footprint, and cold Voc string bounds.

Measured at 310.0 W STC and 281.4 W PTC, Centrosolar America DM72 310 sits -75.0 W vs all-CEC median (below all-CEC median; higher than 25.6% of peers) among 21,677 listed modules. Power density reaches 159.5 W/m2 (3.97 percentage points below 19.91% CEC median). Mid-range 45.7 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, whereas 1,000 V commercial inverters handle up to 19 panels in series. Alternative peer BYD Company Limited BYD 310P6C-36 rates 310.0 W.

Where Does Centrosolar America DM72 310 Fall Across Listed CEC Models?

Distribution marker showing Centrosolar America DM72 310 (310.0 W) relative to the 385.0 W all-CEC solar panel median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DM72 310 (310.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 310.0 W

What Dataset Percentiles Define Centrosolar America DM72 310?

Dataset percentiles tracking Centrosolar America DM72 310 power output, thermal retention ratio, and aperture efficiency against 21,677 models.

Centrosolar America DM72 310 Engineering BenchmarksPercentile comparison of Centrosolar America DM72 310 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage310.0 WPTC/STC Retention90.8%Module Efficiency15.94%

What Do the Dataset Ranks Show for Centrosolar America DM72 310?

Benchmark highlights for Centrosolar America DM72 310 covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.

Rank #15,760 / 21,677

310.0 W STC · Higher Than 25.6%

310.0 W STC (-75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #18,273

15.94% Aperture Efficiency

Power density 159.5 W/m2 (3.97 percentage points below 19.91% CEC median). PTC/STC ratio: 90.8% (rank #17,104).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 50.88 V at -10 C (559.7 V string) and 52.36 V at -20 C (11 max).

8 kW Reference Array

26 Panels = 8,060 W STC

Occupies 50.5 m2 (544 sq ft) producing 7,316 W PTC; NEC 690.8 OCPD floor is 13.73 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 45.7 * (1 + (-0.324/100) * (-10 - 25)) = 50.88 V | OCPD = 1.56 * 8.8 = 13.73 A

Inputs from CEC Modules.csv for Centrosolar America DM72 310: Voc=45.7 V, beta_Voc=-0.324%/C, Isc=8.8 A, STC=310.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (559.7 V); 26 panels for 8 kW (544 sq ft).

What Are the Published CEC Specifications for Centrosolar America DM72 310?

Official CEC datasheet figures for Centrosolar America DM72 310 (Mono-c-Si) used in utility interconnection and permit reviews. Data intervals combine current 2025 federal utility and BLS wage releases with verified state electrical board rosters.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DM72 310.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 310.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 281.4 W (90.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 45.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 8.8 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.9 V / 8.2 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 15.94% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America DM72 310 Panels Build a 6 kW, 8 kW, or 10 kW Array?

How many Centrosolar America DM72 310 modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 20 6.2 kW 419 sq ft $1,552 $2,624
8 kW Class 26 8.06 kW 544 sq ft $2,017 $3,411
10 kW Class 33 10.23 kW 691 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

Consolidated Centrosolar America wattage variants sharing the Centrosolar America DM72 310 mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Sibling CEC listings grouped into the Centrosolar America DM72 310 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DM72 300 300.0 W 272.1 W 45.0 V 37.1 V 15.43%
Centrosolar America DM72 305 305.0 W 276.8 W 45.4 V 37.2 V 15.69%
Centrosolar America DM72 310 310.0 W 281.4 W 45.7 V 37.9 V 15.94%
Centrosolar America DM72 315 315.0 W 286.1 W 46.0 V 38.0 V 16.2%
Centrosolar America DM72 320 320.0 W 290.8 W 46.3 V 38.6 V 16.46%

How Many Centrosolar America DM72 310 Modules Fit in a Cold-Weather String?

NEC 690.7(A) winter string table preventing overvoltage trips on Centrosolar America DM72 310 (50.88 V at 14 F).

Computed from Voc=45.7V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.36 V 11 panels 576.0 V 19 panels
-10 C (14 F) 50.88 V 11 panels 559.7 V 19 panels
0 C (32 F) 49.4 V 12 panels 592.8 V 20 panels
25 C (77 F STC) 45.7 V 13 panels 594.1 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DM72 310?

Competing CEC solar panels closest to Centrosolar America DM72 310 in nameplate wattage and Voc, starting with BYD Company Limited BYD 310P6C-36.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
BYD Company Limited BYD 310P6C-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.2%
BYD Company Limited BYD310P6K-36
BYD Company Limited
310.0 W Tie (0 W) 45.79 V 15.98% 91.6%
Boviet Solar Technology Co Ltd BVM6612P-310
Boviet Solar Technology Co Ltd
310.0 W Tie (0 W) 45.8 V 15.98% 90.3%
DEHUI SOLAR POWER INC DH-72P-310W
DEHUI SOLAR POWER INC
310.0 W Tie (0 W) 45.6 V 16.12% 90.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DM72 310?

Evaluate Centrosolar America DM72 310 (310.0 W STC, 45.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DM72 310 reaches 52.36 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 26 panels for an 8 kW build require 544 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 26 panels (544 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DM72 310 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DM72 310 8 kW Residential Fit

Needs 26 modules (544 sq ft) with a 15 A string OCPD, offsetting ~$2,017/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare BYD Company Limited BYD 310P6C-36.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 281.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DM72 310 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

How many Centrosolar America DM72 310 panels fit on a 600 V winter solar string?

At -10 C (14 F), Centrosolar America DM72 310 cold Voc rises from 45.7 V to 50.88 V (beta_Voc -0.324%/C), capping a 600 V string at 11 panels (559.7 V).

How much roof area does an 8 kW array of Centrosolar America DM72 310 need?

An 8 kW DC system uses 26 Centrosolar America DM72 310 modules (8,060 W STC / 7,316 W PTC), covering roughly 544 sq ft and saving ~$2,017/yr at 18.54 c/kWh.

How does Centrosolar America DM72 310 compare against BYD Company Limited BYD 310P6C-36?

Centrosolar America DM72 310 outputs 310.0 W STC (45.7 V Voc, rank #15,760 of 21,677), while BYD Company Limited BYD 310P6C-36 delivers 310.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.