Centrosolar America EM72 350BW — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America EM72 350BW is a 350.0 W STC (320.3 W PTC) Mono-c-Si solar module ranking #13,031 of 21,677 CEC listings (below all-CEC median; higher than 38.6% of peers). It delivers 18.2% efficiency, 47.64 V Voc at 25 C, and 52.59 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
350.0 W
PTC Wattage
320.3 W
Voc @ 25C
47.64 V
Efficiency
18.2%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America EM72 350BW Compare Against Peer CEC Listings?

How Centrosolar America Centrosolar America EM72 350BW handles rooftop heat (320.3 W PTC), 8 kW sizing, and cold winter string voltage.

Centrosolar America builds the Centrosolar America EM72 350BW (Mono-c-Si) as a compact residential or specialty off-grid module delivering 182.0 W/m2 (1.71 percentage points below 19.91% CEC median). Compared against Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W (350.0 W), this model holds strong 91.5% PTC-to-STC heat retention (#15,584 of 21,677). Mid-range 47.64 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.96 A overcurrent floor served by a 15 A breaker.

Where Does Centrosolar America EM72 350BW Fall Across Listed CEC Models?

Where Centrosolar America EM72 350BW (350.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America EM72 350BW (350.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 350.0 W

What Dataset Percentiles Define Centrosolar America EM72 350BW?

Percentile placement of Centrosolar America EM72 350BW across power density (182.0 W/m2), thermal retention, and nameplate STC wattage.

Centrosolar America EM72 350BW Engineering BenchmarksPercentile comparison of Centrosolar America EM72 350BW wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage350.0 WPTC/STC Retention91.5%Module Efficiency18.2%

What Do the Dataset Ranks Show for Centrosolar America EM72 350BW?

Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America EM72 350BW specifications. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.

Rank #13,031 / 21,677

350.0 W STC · Higher Than 38.6%

350.0 W STC (-35.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #14,823

18.2% Aperture Efficiency

Power density 182.0 W/m2 (1.71 percentage points below 19.91% CEC median). PTC/STC ratio: 91.5% (rank #15,584).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.59 V at -10 C (578.5 V string) and 54.01 V at -20 C (11 max).

8 kW Reference Array

23 Panels = 8,050 W STC

Occupies 44.2 m2 (476 sq ft) producing 7,367 W PTC; NEC 690.8 OCPD floor is 14.96 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 47.64 * (1 + (-0.297/100) * (-10 - 25)) = 52.59 V | OCPD = 1.56 * 9.59 = 14.96 A

Inputs from CEC Modules.csv for Centrosolar America EM72 350BW: Voc=47.64 V, beta_Voc=-0.297%/C, Isc=9.59 A, STC=350.0 W, Area=1.923 m2.

Result: 11 panels max on 600 V (578.5 V); 23 panels for 8 kW (476 sq ft).

What Are the Published CEC Specifications for Centrosolar America EM72 350BW?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America EM72 350BW.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America EM72 350BW.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 350.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 320.3 W (91.5% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 47.64 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.59 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 38.51 V / 9.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.297 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 18.2% (1.923 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America EM72 350BW Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America EM72 350BW (350.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.3 kW 373 sq ft $1,577 $2,666
8 kW Class 23 8.05 kW 476 sq ft $2,015 $3,407
10 kW Class 29 10.15 kW 600 sq ft $2,540 $4,296

How Many Centrosolar America EM72 350BW Modules Fit in a Cold-Weather String?

Maximum series module counts for Centrosolar America EM72 350BW from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=47.64V and beta_Voc=-0.297%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.01 V 11 panels 594.1 V 18 panels
-10 C (14 F) 52.59 V 11 panels 578.5 V 19 panels
0 C (32 F) 51.18 V 11 panels 563.0 V 19 panels
25 C (77 F STC) 47.64 V 12 panels 571.7 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America EM72 350BW?

Alternative CEC solar modules from competing brands near Centrosolar America EM72 350BW (350.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
350.0 W Tie (0 W) 47.64 V 18.2% 91.5%
CSI Solar Co Ltd CS3U-350P-AG
CSI Solar Co Ltd
350.0 W Tie (0 W) 46.6 V 18.23% 92.3%
Bluesun Solar Energy Tech CoLtd BSM355P-72
Bluesun Solar Energy Tech CoLtd
355.0 W +5.0 W 47.52 V 18.32% 91.6%
AXITEC AC-355M/156-72S
AXITEC
355.0 W +5.0 W 47.4 V 18.3% 91.5%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America EM72 350BW?

Evaluate Centrosolar America EM72 350BW (350.0 W STC, 47.64 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America EM72 350BW reaches 54.01 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 23 panels for an 8 kW build require 476 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 23 panels (476 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America EM72 350BW carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America EM72 350BW 8 kW Residential Fit

Needs 23 modules (476 sq ft) with a 15 A string OCPD, offsetting ~$2,015/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6M-350W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 320.3 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America EM72 350BW by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Centrosolar America EM72 350BW?

Multiplying Centrosolar America EM72 350BW's 9.59 A short-circuit current by 1.56 equals 14.96 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can Centrosolar America EM72 350BW pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 52.59 V cold Voc at 14 F and handles 9.59 A Isc; string inverters cap Centrosolar America EM72 350BW at 11 panels on 600 V.

Is Centrosolar America EM72 350BW eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Centrosolar America EM72 350BW rely on utility bill offset (~$2,015/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.