Skip to main content
WireAndSun
Calculators
CEC PV Module

Centrosolar America DM72 330 — CEC Solar Module Specifications

Manufacturer: Centrosolar America Registry: CEC Verified Engineering Specification

Centrosolar America DM72 330 is a 330.0 W STC (300.1 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 16.97% efficiency, 46.9 V Voc at 25 C, and 52.22 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
300.1 W
Voc @ 25C
46.9 V
Efficiency
16.97%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Centrosolar America DM72 330 Compare Against Peer CEC Listings?

How Centrosolar America Centrosolar America DM72 330 handles rooftop heat (300.1 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Centrosolar America DM72 330 exhibits 9.0 A short-circuit current, requiring a 14.04 A (156%) conductor rating and 15 A OCPD under NEC 690.8. Ranked #14,165 of 21,677 (80.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 48.6 m2 for an 8 kW system (31 panels for 10 kW). Mid-range 46.9 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F.

Where Does Centrosolar America DM72 330 Fall Across Listed CEC Models?

Where Centrosolar America DM72 330 (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Centrosolar America DM72 330 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCentrosolar Americ: 330.0 W

What Dataset Percentiles Define Centrosolar America DM72 330?

Percentile placement of Centrosolar America DM72 330 across power density (169.8 W/m2), thermal retention, and nameplate STC wattage.

Centrosolar America DM72 330 Engineering BenchmarksPercentile comparison of Centrosolar America DM72 330 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.9%Module Efficiency16.97%

What Do the Dataset Ranks Show for Centrosolar America DM72 330?

Four critical engineering numbers homeowners and solar installers check first when reviewing Centrosolar America DM72 330 specifications. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #16,576

16.97% Aperture Efficiency

Power density 169.8 W/m2 (2.94 percentage points below 19.91% CEC median). PTC/STC ratio: 90.9% (rank #16,906).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 52.22 V at -10 C (574.4 V string) and 53.74 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.6 m2 (523 sq ft) producing 7,502 W PTC; NEC 690.8 OCPD floor is 14.04 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.9 * (1 + (-0.324/100) * (-10 - 25)) = 52.22 V | OCPD = 1.56 * 9.0 = 14.04 A

Inputs from CEC Modules.csv for Centrosolar America DM72 330: Voc=46.9 V, beta_Voc=-0.324%/C, Isc=9.0 A, STC=330.0 W, Area=1.944 m2.

Result: 11 panels max on 600 V (574.4 V); 25 panels for 8 kW (523 sq ft).

What Are the Published CEC Specifications for Centrosolar America DM72 330?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Centrosolar America DM72 330.

Official California Energy Commission (NREL SAM) test parameters for Centrosolar America DM72 330.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 300.1 W (90.9% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.0 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 39.3 V / 8.4 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.324 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 16.97% (1.944 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Centrosolar America DM72 330 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Centrosolar America DM72 330 (330.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 398 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 523 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 649 sq ft $2,560 $4,330

Which Sibling Wattage & Trim Variants Belong to This Centrosolar America Series?

All closely matched Centrosolar America wattages and cosmetic trims sharing the Centrosolar America DM72 330 architecture. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Sibling CEC listings grouped into the Centrosolar America DM72 330 wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Centrosolar America DM72 325 325.0 W 295.4 W 46.6 V 38.7 V 16.72%
Centrosolar America DM72 330 330.0 W 300.1 W 46.9 V 39.3 V 16.97%
Centrosolar America DM72 335 335.0 W 304.8 W 47.2 V 39.5 V 17.23%

How Many Centrosolar America DM72 330 Modules Fit in a Cold-Weather String?

Maximum series module counts for Centrosolar America DM72 330 from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=46.9V and beta_Voc=-0.324%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 53.74 V 11 panels 591.1 V 18 panels
-10 C (14 F) 52.22 V 11 panels 574.4 V 19 panels
0 C (32 F) 50.7 V 11 panels 557.7 V 19 panels
25 C (77 F STC) 46.9 V 12 panels 562.8 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to Centrosolar America DM72 330?

Alternative CEC solar modules from competing brands near Centrosolar America DM72 330 (330.0 W), including Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W
Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd
330.0 W Tie (0 W) 46.65 V 17.16% 91.3%
GCL System Integration Technology Co Ltd GCL-M6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.4%
GCL System Integration Technology Co Ltd GCL-P6/72330
GCL System Integration Technology Co Ltd
330.0 W Tie (0 W) 46.2 V 17.01% 90.7%
Advance Power API-P330
Advance Power
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Centrosolar America DM72 330?

Evaluate Centrosolar America DM72 330 (330.0 W STC, 46.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Centrosolar America DM72 330 reaches 53.74 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 523 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (523 sq ft).
  • 2026 tax credit baseline: cash residential installs of Centrosolar America DM72 330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Centrosolar America DM72 330 8 kW Residential Fit

Needs 25 modules (523 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 300.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Centrosolar America DM72 330 by Centrosolar America grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Centrosolar America DM72 330 PTC wattage (300.1 W) lower than STC (330.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 300.1 W PTC (90.9% retention) across Centrosolar America DM72 330's 1.944 m2 aperture.

Who should skip Centrosolar America DM72 330 on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 25 Centrosolar America DM72 330 panels (523 sq ft) leave unusable roof gaps vs. Amerisolar-Worldwide Energy and Manufacturing USA Co Ltd AS-6P-330W.

What is the 1,000 V commercial string limit for Centrosolar America DM72 330?

On 1,000 V commercial inverters at -10 C (52.22 V cold Voc), Centrosolar America DM72 330 fits up to 19 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Centrosolar America DM72 330.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls