Skip to main content
WireAndSun
Calculators
CEC PV Module

GCL System Integration Technology Co Ltd GCL-P6/72330 — CEC Solar Module Specifications

Manufacturer: GCL System Integration Technology Co Ltd Registry: CEC Verified Engineering Specification

GCL System Integration Technology Co Ltd GCL-P6/72330 is a 330.0 W STC (299.4 W PTC) Multi-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.2 V Voc at 25 C, and 51.1 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
330.0 W
PTC Wattage
299.4 W
Voc @ 25C
46.2 V
Efficiency
17.01%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does GCL System Integration Technology Co Ltd GCL-P6/72330 Compare Against Peer CEC Listings?

Engineering position of GCL System Integration Technology Co Ltd GCL-P6/72330 (330.0 W STC) vs. Centrosolar America TM7 330SW across 1,407 CEC Multi-c-Si solar modules.

Built with 72 Multi-c-Si cells, GCL System Integration Technology Co Ltd GCL-P6/72330 pairs typical 90.7% PTC-to-STC thermal output (299.4 W real-world rating) with 46.2 V nominal Voc. An 8 kW residential build (8,250 W DC, 7,485 W PTC) saves ~$2,065/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Centrosolar America TM7 330SW offers a 330.0 W alternative.

Where Does GCL System Integration Technology Co Ltd GCL-P6/72330 Fall Across Listed CEC Models?

Plots GCL System Integration Technology Co Ltd GCL-P6/72330 at 330.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where GCL System Integration Technology Co Ltd GCL-P6/72330 (330.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCGCL System Integra: 330.0 W

What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-P6/72330?

Benchmarks GCL System Integration Technology Co Ltd GCL-P6/72330 on STC wattage, thermal PTC/STC retention, and 17.01 aperture conversion efficiency against CEC peers.

GCL System Integration Technology Co Ltd GCL-P6/72330 Engineering BenchmarksPercentile comparison of GCL System Integration Technology Co Ltd GCL-P6/72330 wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage330.0 WPTC/STC Retention90.7%Module Efficiency17.01%

What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-P6/72330?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for GCL System Integration Technology Co Ltd GCL-P6/72330 by GCL System Integration Technology Co Ltd.

Rank #14,165 / 21,677

330.0 W STC · Higher Than 32.9%

330.0 W STC (-55.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.

Eff #16,431

17.01% Aperture Efficiency

Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.7% (rank #17,330).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 51.1 V at -10 C (562.1 V string) and 52.5 V at -20 C (11 max).

8 kW Reference Array

25 Panels = 8,250 W STC

Occupies 48.5 m2 (522 sq ft) producing 7,485 W PTC; NEC 690.8 OCPD floor is 14.55 A (15 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 46.2 * (1 + (-0.303/100) * (-10 - 25)) = 51.1 V | OCPD = 1.56 * 9.33 = 14.55 A

Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-P6/72330: Voc=46.2 V, beta_Voc=-0.303%/C, Isc=9.33 A, STC=330.0 W, Area=1.94 m2.

Result: 11 panels max on 600 V (562.1 V); 25 panels for 8 kW (522 sq ft).

What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-P6/72330?

Laboratory test ratings recorded for GCL System Integration Technology Co Ltd GCL-P6/72330 (Multi-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for GCL System Integration Technology Co Ltd GCL-P6/72330.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 330.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 299.4 W (90.7% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 46.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 9.33 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 37.8 V / 8.73 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.303 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 17.01% (1.94 m2) Array roof footprint density
Cell Count & Technology 72 cells (Multi-c-Si) Monofacial backsheet

How Many GCL System Integration Technology Co Ltd GCL-P6/72330 Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (522 sq ft at 8 kW), and estimated Year-1 electric bill offset for GCL System Integration Technology Co Ltd GCL-P6/72330.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 19 6.27 kW 397 sq ft $1,569 $2,654
8 kW Class 25 8.25 kW 522 sq ft $2,065 $3,492
10 kW Class 31 10.23 kW 647 sq ft $2,560 $4,330

How Many GCL System Integration Technology Co Ltd GCL-P6/72330 Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for GCL System Integration Technology Co Ltd GCL-P6/72330 (beta_Voc -0.303%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=46.2V and beta_Voc=-0.303%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 52.5 V 11 panels 577.5 V 19 panels
-10 C (14 F) 51.1 V 11 panels 562.1 V 19 panels
0 C (32 F) 49.7 V 12 panels 596.4 V 20 panels
25 C (77 F STC) 46.2 V 12 panels 554.4 V 21 panels

Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-P6/72330?

Closest cross-brand CEC competitors to GCL System Integration Technology Co Ltd GCL-P6/72330 matched near 330.0 W STC and 46.2 V Voc, led by Centrosolar America TM7 330SW.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Centrosolar America TM7 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
Centrosolar America TM7S 330SW
Centrosolar America
330.0 W Tie (0 W) 46.1 V 16.92% 91.0%
Advance Power API-P330
Advance Power
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
Auxin Solar AXN6P612T330
Auxin Solar
330.0 W Tie (0 W) 46.08 V 17.01% 90.3%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-P6/72330?

Evaluate GCL System Integration Technology Co Ltd GCL-P6/72330 (330.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-P6/72330 reaches 52.5 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
  • 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-P6/72330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

GCL System Integration Technology Co Ltd GCL-P6/72330 8 kW Residential Fit

Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America TM7 330SW.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 299.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for GCL System Integration Technology Co Ltd GCL-P6/72330 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-P6/72330?

Multiplying GCL System Integration Technology Co Ltd GCL-P6/72330's 9.33 A short-circuit current by 1.56 equals 14.55 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.

Can GCL System Integration Technology Co Ltd GCL-P6/72330 pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 51.1 V cold Voc at 14 F and handles 9.33 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-P6/72330 at 11 panels on 600 V.

Is GCL System Integration Technology Co Ltd GCL-P6/72330 eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-P6/72330 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.