GCL System Integration Technology Co Ltd GCL-M6/72330 is a 330.0 W STC (298.3 W PTC) Mono-c-Si solar module ranking #14,165 of 21,677 CEC listings (below all-CEC median; higher than 32.9% of peers). It delivers 17.01% efficiency, 46.2 V Voc at 25 C, and 51.5 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 330.0 W
- PTC Wattage
- 298.3 W
- Voc @ 25C
- 46.2 V
- Efficiency
- 17.01%
How Does GCL System Integration Technology Co Ltd GCL-M6/72330 Compare Against Peer CEC Listings?
How GCL System Integration Technology Co Ltd GCL System Integration Technology Co Ltd GCL-M6/72330 handles rooftop heat (298.3 W PTC), 8 kW sizing, and cold winter string voltage.
GCL System Integration Technology Co Ltd builds the GCL System Integration Technology Co Ltd GCL-M6/72330 (Mono-c-Si) as a compact residential or specialty off-grid module delivering 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). Compared against Centrosolar America TM7 330SW (330.0 W), this model holds typical 90.4% PTC-to-STC thermal output (298.3 W real-world rating). Mid-range 46.2 V open-circuit voltage allows up to 11 panels per 600 V string at 14 F, while NEC 690.8 sets a 14.55 A overcurrent floor served by a 15 A breaker.
Where Does GCL System Integration Technology Co Ltd GCL-M6/72330 Fall Across Listed CEC Models?
Where GCL System Integration Technology Co Ltd GCL-M6/72330 (330.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.
What Dataset Percentiles Define GCL System Integration Technology Co Ltd GCL-M6/72330?
Percentile placement of GCL System Integration Technology Co Ltd GCL-M6/72330 across power density (170.1 W/m2), thermal retention, and nameplate STC wattage.
What Do the Dataset Ranks Show for GCL System Integration Technology Co Ltd GCL-M6/72330?
Four critical engineering numbers homeowners and solar installers check first when reviewing GCL System Integration Technology Co Ltd GCL-M6/72330 specifications.
330.0 W STC · Higher Than 32.9%
330.0 W STC (-55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
17.01% Aperture Efficiency
Power density 170.1 W/m2 (2.90 percentage points below 19.91% CEC median). PTC/STC ratio: 90.4% (rank #18,018).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 51.5 V at -10 C (566.5 V string) and 53.02 V at -20 C (11 max).
25 Panels = 8,250 W STC
Occupies 48.5 m2 (522 sq ft) producing 7,458 W PTC; NEC 690.8 OCPD floor is 14.55 A (15 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 46.2 * (1 + (-0.328/100) * (-10 - 25)) = 51.5 V | OCPD = 1.56 * 9.33 = 14.55 A
Inputs from CEC Modules.csv for GCL System Integration Technology Co Ltd GCL-M6/72330: Voc=46.2 V, beta_Voc=-0.328%/C, Isc=9.33 A, STC=330.0 W, Area=1.94 m2.
Result: 11 panels max on 600 V (566.5 V); 25 panels for 8 kW (522 sq ft).
What Are the Published CEC Specifications for GCL System Integration Technology Co Ltd GCL-M6/72330?
Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for GCL System Integration Technology Co Ltd GCL-M6/72330.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 330.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 298.3 W (90.4% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 46.2 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.33 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 37.8 V / 8.73 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.328 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 17.01% (1.94 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many GCL System Integration Technology Co Ltd GCL-M6/72330 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using GCL System Integration Technology Co Ltd GCL-M6/72330 (330.0 W).
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 19 | 6.27 kW | 397 sq ft | $1,569 | $2,654 |
| 8 kW Class | 25 | 8.25 kW | 522 sq ft | $2,065 | $3,492 |
| 10 kW Class | 31 | 10.23 kW | 647 sq ft | $2,560 | $4,330 |
How Many GCL System Integration Technology Co Ltd GCL-M6/72330 Modules Fit in a Cold-Weather String?
Maximum series module counts for GCL System Integration Technology Co Ltd GCL-M6/72330 from 25 C down to -20 C (-4 F) under NEC 690.7.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 53.02 V | 11 panels | 583.2 V | 18 panels |
| -10 C (14 F) | 51.5 V | 11 panels | 566.5 V | 19 panels |
| 0 C (32 F) | 49.99 V | 12 panels | 599.9 V | 20 panels |
| 25 C (77 F STC) | 46.2 V | 12 panels | 554.4 V | 21 panels |
Which Cross-Brand Solar Modules Compare Closest to GCL System Integration Technology Co Ltd GCL-M6/72330?
Alternative CEC solar modules from competing brands near GCL System Integration Technology Co Ltd GCL-M6/72330 (330.0 W), including Centrosolar America TM7 330SW.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Centrosolar America TM7 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Centrosolar America TM7S 330SW Centrosolar America |
330.0 W | Tie (0 W) | 46.1 V | 16.92% | 91.0% |
| Advance Power API-P330 Advance Power |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
| Auxin Solar AXN6P612T330 Auxin Solar |
330.0 W | Tie (0 W) | 46.08 V | 17.01% | 90.3% |
What Are the Design Limits and Best-Fit Uses for GCL System Integration Technology Co Ltd GCL-M6/72330?
Evaluate GCL System Integration Technology Co Ltd GCL-M6/72330 (330.0 W STC, 46.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), GCL System Integration Technology Co Ltd GCL-M6/72330 reaches 53.02 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 25 panels for an 8 kW build require 522 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 25 panels (522 sq ft).
- 2026 tax credit baseline: cash residential installs of GCL System Integration Technology Co Ltd GCL-M6/72330 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
GCL System Integration Technology Co Ltd GCL-M6/72330 8 kW Residential Fit
Needs 25 modules (522 sq ft) with a 15 A string OCPD, offsetting ~$2,065/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Centrosolar America TM7 330SW.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 298.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for GCL System Integration Technology Co Ltd GCL-M6/72330 by GCL System Integration Technology Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for GCL System Integration Technology Co Ltd GCL-M6/72330?
Multiplying GCL System Integration Technology Co Ltd GCL-M6/72330's 9.33 A short-circuit current by 1.56 equals 14.55 A minimum ampacity, requiring at least a 15 A overcurrent fuse or breaker.
Can GCL System Integration Technology Co Ltd GCL-M6/72330 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 51.5 V cold Voc at 14 F and handles 9.33 A Isc; string inverters cap GCL System Integration Technology Co Ltd GCL-M6/72330 at 11 panels on 600 V.
Is GCL System Integration Technology Co Ltd GCL-M6/72330 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of GCL System Integration Technology Co Ltd GCL-M6/72330 rely on utility bill offset (~$2,065/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)