Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 72M-405 G1 Bifacial is a 405.0 W STC (374.4 W PTC) Mono-c-Si solar module ranking #8,961 of 21,677 CEC listings (top 43.4%; higher than 56.6% of peers). It delivers 21.09% efficiency, 49.9 V Voc at 25 C, and 54.51 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
405.0 W
PTC Wattage
374.4 W
Voc @ 25C
49.9 V
Efficiency
21.09%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 72M-405 G1 Bifacial Compare Against Peer CEC Listings?

Engineering position of Heliene 72M-405 G1 Bifacial (405.0 W STC) vs. Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF across 5,889 CEC Mono-c-Si solar modules.

Ranking #8,961 across 21,677 CEC solar panels (top 43.4%; higher than 56.6% of peers), Heliene 72M-405 G1 Bifacial operates as a modern high-density residential and light-commercial module sitting 5.0 W below the 410.0 W Mono-c-Si median. Higher 49.9 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 92.4% PTC-to-STC heat retention (#12,969 of 21,677), 20 panels occupy 413 sq ft and offset roughly $2,027/yr at average US rates (or $3,428/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Heliene 72M-405 G1 Bifacial Fall Across Listed CEC Models?

Plots Heliene 72M-405 G1 Bifacial at 405.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 72M-405 G1 Bifacial (405.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 72M-405 G1: 405.0 W

What Dataset Percentiles Define Heliene 72M-405 G1 Bifacial?

Benchmarks Heliene 72M-405 G1 Bifacial on STC wattage, thermal PTC/STC retention, and 21.09 aperture conversion efficiency against CEC peers.

Heliene 72M-405 G1 Bifacial Engineering BenchmarksPercentile comparison of Heliene 72M-405 G1 Bifacial wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage405.0 WPTC/STC Retention92.4%Module Efficiency21.09%

What Do the Dataset Ranks Show for Heliene 72M-405 G1 Bifacial?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Heliene 72M-405 G1 Bifacial by Heliene.

Rank #8,961 / 21,677

Top 43.4% STC Output

405.0 W STC (+20.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #5,965

21.09% Aperture Efficiency

Power density 210.9 W/m2 (1.18 percentage points above 19.91% CEC median). PTC/STC ratio: 92.4% (rank #12,969).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.51 V at -10 C (599.6 V string) and 55.83 V at -20 C (10 max).

8 kW Reference Array

20 Panels = 8,100 W STC

Occupies 38.4 m2 (413 sq ft) producing 7,488 W PTC; NEC 690.8 OCPD floor is 16.24 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.9 * (1 + (-0.264/100) * (-10 - 25)) = 54.51 V | OCPD = 1.56 * 10.41 = 16.24 A

Inputs from CEC Modules.csv for Heliene 72M-405 G1 Bifacial: Voc=49.9 V, beta_Voc=-0.264%/C, Isc=10.41 A, STC=405.0 W, Area=1.92 m2.

Result: 11 panels max on 600 V (599.6 V); 20 panels for 8 kW (413 sq ft).

What Are the Published CEC Specifications for Heliene 72M-405 G1 Bifacial?

Laboratory test ratings recorded for Heliene 72M-405 G1 Bifacial (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Heliene 72M-405 G1 Bifacial.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 405.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 374.4 W (92.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.9 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 10.41 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.0 V / 9.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.264 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.09% (1.92 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Heliene 72M-405 G1 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (413 sq ft at 8 kW), and estimated Year-1 electric bill offset for Heliene 72M-405 G1 Bifacial.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 15 6.08 kW 310 sq ft $1,522 $2,573
8 kW Class 20 8.1 kW 413 sq ft $2,027 $3,428
10 kW Class 25 10.12 kW 517 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Sibling wattage bins and frame colors grouped with Heliene 72M-405 G1 Bifacial under Heliene to prevent duplicate spec pages.

Sibling CEC listings grouped into the Heliene 72M-405 G1 Bifacial wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 72M-400 G1 Bifacial 400.0 W 369.6 W 49.58 V 40.7 V 20.83%
Heliene 72M-405 G1 Bifacial 405.0 W 374.4 W 49.9 V 41.0 V 21.09%

How Many Heliene 72M-405 G1 Bifacial Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Heliene 72M-405 G1 Bifacial (beta_Voc -0.264%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.9V and beta_Voc=-0.264%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.83 V 10 panels 558.3 V 17 panels
-10 C (14 F) 54.51 V 11 panels 599.6 V 18 panels
0 C (32 F) 53.19 V 11 panels 585.1 V 18 panels
25 C (77 F STC) 49.9 V 12 panels 598.8 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 72M-405 G1 Bifacial?

Closest cross-brand CEC competitors to Heliene 72M-405 G1 Bifacial matched near 405.0 W STC and 49.9 V Voc, led by Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.15% 93.4%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF-DG
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 20.05% 93.7%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.76% 93.7%
Boviet Solar Technology Co Ltd BVM6612M-405L-H-HC-BF-DG
Boviet Solar Technology Co Ltd
405.0 W Tie (0 W) 49.45 V 19.76% 93.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 72M-405 G1 Bifacial?

Evaluate Heliene 72M-405 G1 Bifacial (405.0 W STC, 49.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 72M-405 G1 Bifacial reaches 55.83 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 20 panels for an 8 kW build require 413 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 20 panels (413 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 72M-405 G1 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 72M-405 G1 Bifacial 8 kW Residential Fit

Needs 20 modules (413 sq ft) with a 20 A string OCPD, offsetting ~$2,027/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 374.4 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 72M-405 G1 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

How many Heliene 72M-405 G1 Bifacial panels fit on a 600 V winter solar string?

At -10 C (14 F), Heliene 72M-405 G1 Bifacial cold Voc rises from 49.9 V to 54.51 V (beta_Voc -0.264%/C), capping a 600 V string at 11 panels (599.6 V).

How much roof area does an 8 kW array of Heliene 72M-405 G1 Bifacial need?

An 8 kW DC system uses 20 Heliene 72M-405 G1 Bifacial modules (8,100 W STC / 7,488 W PTC), covering roughly 413 sq ft and saving ~$2,027/yr at 18.54 c/kWh.

How does Heliene 72M-405 G1 Bifacial compare against Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF?

Heliene 72M-405 G1 Bifacial outputs 405.0 W STC (49.9 V Voc, rank #8,961 of 21,677), while Boviet Solar Technology Co Ltd BVM6612M-405L-H-BF delivers 405.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?