Skip to main content
WireAndSun
Calculators
CEC PV Module

Heliene 144HC-460 Bifacial — CEC Solar Module Specifications

Manufacturer: Heliene Registry: CEC Verified Engineering Specification

Heliene 144HC-460 Bifacial is a 460.0 W STC (429.8 W PTC) Mono-c-Si solar module ranking #5,199 of 21,677 CEC listings (top 25.0%; higher than 75.0% of peers). It delivers 20.81% efficiency, 51.26 V Voc at 25 C, and 55.96 V cold Voc at -10 C (10 panels max per 600 V string).

STC Wattage
460.0 W
PTC Wattage
429.8 W
Voc @ 25C
51.26 V
Efficiency
20.81%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Heliene 144HC-460 Bifacial Compare Against Peer CEC Listings?

CEC rank, roof space requirements, and NEC 690.7/690.8 limits for Heliene 144HC-460 Bifacial (Mono-c-Si) residential solar systems.

Homeowners evaluating Heliene 144HC-460 Bifacial need 14 panels for 6 kW or 18 panels (428 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.262%/C) pushes open-circuit voltage to 55.96 V at 14 F and 57.3 V at -4 F. Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Heliene 144HC-460 Bifacial Fall Across Listed CEC Models?

Comparison of Heliene 144HC-460 Bifacial (460.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Heliene 144HC-460 Bifacial (460.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCHeliene 144HC-460 : 460.0 W

What Dataset Percentiles Define Heliene 144HC-460 Bifacial?

Relative ranking of Heliene 144HC-460 Bifacial across nameplate watts, 93.4% PTC thermal ratio, and module aperture efficiency. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.

Heliene 144HC-460 Bifacial Engineering BenchmarksPercentile comparison of Heliene 144HC-460 Bifacial wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage460.0 WPTC/STC Retention93.4%Module Efficiency20.81%

What Do the Dataset Ranks Show for Heliene 144HC-460 Bifacial?

Summary of Heliene 144HC-460 Bifacial output rank, 8 kW array size (18 panels), efficiency rating, and 600 V string limit.

Rank #5,199 / 21,677

Top 25.0% STC Output

460.0 W STC (+75.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #7,197

20.81% Aperture Efficiency

Power density 208.1 W/m2 (0.90 percentage points above 19.91% CEC median). PTC/STC ratio: 93.4% (rank #7,716).

NEC 690.7 Limit

10 Panels Max @ -10 C (600 V)

Cold Voc reaches 55.96 V at -10 C (559.6 V string) and 57.3 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,280 W STC

Occupies 39.8 m2 (428 sq ft) producing 7,736 W PTC; NEC 690.8 OCPD floor is 18.61 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 51.26 * (1 + (-0.262/100) * (-10 - 25)) = 55.96 V | OCPD = 1.56 * 11.93 = 18.61 A

Inputs from CEC Modules.csv for Heliene 144HC-460 Bifacial: Voc=51.26 V, beta_Voc=-0.262%/C, Isc=11.93 A, STC=460.0 W, Area=2.21 m2.

Result: 10 panels max on 600 V (559.6 V); 18 panels for 8 kW (428 sq ft).

What Are the Published CEC Specifications for Heliene 144HC-460 Bifacial?

Complete CEC test sheet for Heliene 144HC-460 Bifacial including Isc (11.93 A), Voc (51.26 V), and thermal temperature coefficients.

Official California Energy Commission (NREL SAM) test parameters for Heliene 144HC-460 Bifacial.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 460.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 429.8 W (93.4% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 51.26 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.93 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 42.31 V / 10.88 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.262 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.81% (2.21 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Heliene 144HC-460 Bifacial Panels Build a 6 kW, 8 kW, or 10 kW Array?

Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using Heliene 144HC-460 Bifacial.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.44 kW 333 sq ft $1,612 $2,726
8 kW Class 18 8.28 kW 428 sq ft $2,072 $3,504
10 kW Class 22 10.12 kW 523 sq ft $2,533 $4,283

Which Sibling Wattage & Trim Variants Belong to This Heliene Series?

Related Heliene power steps and black/silver trims consolidated into this Heliene 144HC-460 Bifacial series guide. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.

Sibling CEC listings grouped into the Heliene 144HC-460 Bifacial wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Heliene 144HC-450 Bifacial 450.0 W 420.2 W 50.74 V 42.17 V 20.36%
Heliene 144HC-460 Bifacial 460.0 W 429.8 W 51.26 V 42.31 V 20.81%

How Many Heliene 144HC-460 Bifacial Modules Fit in a Cold-Weather String?

Verify freezing-morning voltage rise for Heliene 144HC-460 Bifacial (51.26 V STC) before wiring 600 V or 1,000 V strings.

Computed from Voc=51.26V and beta_Voc=-0.262%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 57.3 V 10 panels 573.0 V 17 panels
-10 C (14 F) 55.96 V 10 panels 559.6 V 17 panels
0 C (32 F) 54.62 V 10 panels 546.2 V 18 panels
25 C (77 F STC) 51.26 V 11 panels 563.9 V 19 panels

Which Cross-Brand Solar Modules Compare Closest to Heliene 144HC-460 Bifacial?

Four comparable CEC modules such as CSI Solar Co Ltd CS3Y-460PB-AG (460.0 W) for side-by-side solar quote checks.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3Y-460PB-AG
CSI Solar Co Ltd
460.0 W Tie (0 W) 52.0 V 20.0% 93.7%
Bluesun Solar CoLtd BSM455M-72HBD
Bluesun Solar CoLtd
455.0 W -5.0 W 50.6 V 20.97% 92.7%
Caterpillar Inc PVC455MB03H
Caterpillar Inc
455.0 W -5.0 W 49.8 V 21.56% 93.8%
CSI Solar Co Ltd CS3W-455MB-AG
CSI Solar Co Ltd
455.0 W -5.0 W 49.3 V 21.06% 92.9%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Heliene 144HC-460 Bifacial?

Evaluate Heliene 144HC-460 Bifacial (460.0 W STC, 51.26 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Heliene 144HC-460 Bifacial reaches 57.3 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 428 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (428 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Heliene 144HC-460 Bifacial carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Heliene 144HC-460 Bifacial 8 kW Residential Fit

Needs 18 modules (428 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 10 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3Y-460PB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 429.8 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Heliene 144HC-460 Bifacial by Heliene grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Heliene 144HC-460 Bifacial PTC wattage (429.8 W) lower than STC (460.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 429.8 W PTC (93.4% retention) across Heliene 144HC-460 Bifacial's 2.21 m2 aperture.

Who should skip Heliene 144HC-460 Bifacial on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 18 Heliene 144HC-460 Bifacial panels (428 sq ft) leave unusable roof gaps vs. CSI Solar Co Ltd CS3Y-460PB-AG.

What is the 1,000 V commercial string limit for Heliene 144HC-460 Bifacial?

On 1,000 V commercial inverters at -10 C (55.96 V cold Voc), Heliene 144HC-460 Bifacial fits up to 17 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Heliene 144HC-460 Bifacial.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.