Manufacturer: Caterpillar Inc Registry: CEC Verified Engineering Specification

Caterpillar Inc PVC455MB03H is a 455.0 W STC (427.0 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.56% efficiency, 49.8 V Voc at 25 C, and 54.31 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
455.0 W
PTC Wattage
427.0 W
Voc @ 25C
49.8 V
Efficiency
21.56%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Caterpillar Inc PVC455MB03H Compare Against Peer CEC Listings?

Engineering position of Caterpillar Inc PVC455MB03H (455.0 W STC) vs. CSI Solar Co Ltd CS3W-455MB-AG across 5,889 CEC Mono-c-Si solar modules.

Ranking #5,417 across 21,677 CEC solar panels (top 26.2%; higher than 73.8% of peers), Caterpillar Inc PVC455MB03H operates as a modern high-density residential and light-commercial module sitting 45.0 W above the 410.0 W Mono-c-Si median. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), 18 panels occupy 409 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.

Where Does Caterpillar Inc PVC455MB03H Fall Across Listed CEC Models?

Plots Caterpillar Inc PVC455MB03H at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Caterpillar Inc PVC455MB03H (455.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCaterpillar Inc PV: 455.0 W

What Dataset Percentiles Define Caterpillar Inc PVC455MB03H?

Benchmarks Caterpillar Inc PVC455MB03H on STC wattage, thermal PTC/STC retention, and 21.56 aperture conversion efficiency against CEC peers.

Caterpillar Inc PVC455MB03H Engineering BenchmarksPercentile comparison of Caterpillar Inc PVC455MB03H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage455.0 WPTC/STC Retention93.8%Module Efficiency21.56%

What Do the Dataset Ranks Show for Caterpillar Inc PVC455MB03H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVC455MB03H by Caterpillar Inc.

Rank #5,417 / 21,677

Top 26.2% STC Output

455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #4,227

21.56% Aperture Efficiency

Power density 215.6 W/m2 (1.65 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 54.31 V at -10 C (597.4 V string) and 55.6 V at -20 C (10 max).

8 kW Reference Array

18 Panels = 8,190 W STC

Occupies 38.0 m2 (409 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 18.17 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 49.8 * (1 + (-0.259/100) * (-10 - 25)) = 54.31 V | OCPD = 1.56 * 11.65 = 18.17 A

Inputs from CEC Modules.csv for Caterpillar Inc PVC455MB03H: Voc=49.8 V, beta_Voc=-0.259%/C, Isc=11.65 A, STC=455.0 W, Area=2.11 m2.

Result: 11 panels max on 600 V (597.4 V); 18 panels for 8 kW (409 sq ft).

What Are the Published CEC Specifications for Caterpillar Inc PVC455MB03H?

Laboratory test ratings recorded for Caterpillar Inc PVC455MB03H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVC455MB03H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 455.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 427.0 W (93.8% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 49.8 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.65 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 41.6 V / 10.93 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.259 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 21.56% (2.11 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Bifacial glass-glass

How Many Caterpillar Inc PVC455MB03H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (409 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVC455MB03H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.37 kW 318 sq ft $1,594 $2,696
8 kW Class 18 8.19 kW 409 sq ft $2,050 $3,466
10 kW Class 22 10.01 kW 500 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Sibling wattage bins and frame colors grouped with Caterpillar Inc PVC455MB03H under Caterpillar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Caterpillar Inc PVC455MB03H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Caterpillar Inc PVC450MB03H 450.0 W 422.2 W 49.6 V 41.4 V 21.33%
Caterpillar Inc PVC455MB03H 455.0 W 427.0 W 49.8 V 41.6 V 21.56%

How Many Caterpillar Inc PVC455MB03H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Caterpillar Inc PVC455MB03H (beta_Voc -0.259%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=49.8V and beta_Voc=-0.259%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 55.6 V 10 panels 556.0 V 17 panels
-10 C (14 F) 54.31 V 11 panels 597.4 V 18 panels
0 C (32 F) 53.02 V 11 panels 583.2 V 18 panels
25 C (77 F STC) 49.8 V 12 panels 597.6 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC455MB03H?

Closest cross-brand CEC competitors to Caterpillar Inc PVC455MB03H matched near 455.0 W STC and 49.8 V Voc, led by CSI Solar Co Ltd CS3W-455MB-AG.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3W-455MB-AG
CSI Solar Co Ltd
455.0 W Tie (0 W) 49.3 V 21.06% 92.9%
Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF
Boviet Solar Technology Co Ltd
455.0 W Tie (0 W) 49.25 V 20.4% 93.8%
Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF-DG
Boviet Solar Technology Co Ltd
455.0 W Tie (0 W) 49.25 V 20.4% 93.8%
Bluesun Solar CoLtd BSM455M-72HBD
Bluesun Solar CoLtd
455.0 W Tie (0 W) 50.6 V 20.97% 92.7%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC455MB03H?

Evaluate Caterpillar Inc PVC455MB03H (455.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC455MB03H reaches 55.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 18 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (409 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC455MB03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Caterpillar Inc PVC455MB03H 8 kW Residential Fit

Needs 18 modules (409 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3W-455MB-AG.

Bifacial / High-Heat Roof Check

Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 427.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVC455MB03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

How many Caterpillar Inc PVC455MB03H panels fit on a 600 V winter solar string?

At -10 C (14 F), Caterpillar Inc PVC455MB03H cold Voc rises from 49.8 V to 54.31 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (597.4 V).

How much roof area does an 8 kW array of Caterpillar Inc PVC455MB03H need?

An 8 kW DC system uses 18 Caterpillar Inc PVC455MB03H modules (8,190 W STC / 7,686 W PTC), covering roughly 409 sq ft and saving ~$2,050/yr at 18.54 c/kWh.

How does Caterpillar Inc PVC455MB03H compare against CSI Solar Co Ltd CS3W-455MB-AG?

Caterpillar Inc PVC455MB03H outputs 455.0 W STC (49.8 V Voc, rank #5,417 of 21,677), while CSI Solar Co Ltd CS3W-455MB-AG delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.