Caterpillar Inc PVC455MB03H is a 455.0 W STC (427.0 W PTC) Mono-c-Si solar module ranking #5,417 of 21,677 CEC listings (top 26.2%; higher than 73.8% of peers). It delivers 21.56% efficiency, 49.8 V Voc at 25 C, and 54.31 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 455.0 W
- PTC Wattage
- 427.0 W
- Voc @ 25C
- 49.8 V
- Efficiency
- 21.56%
How Does Caterpillar Inc PVC455MB03H Compare Against Peer CEC Listings?
Engineering position of Caterpillar Inc PVC455MB03H (455.0 W STC) vs. CSI Solar Co Ltd CS3W-455MB-AG across 5,889 CEC Mono-c-Si solar modules.
Ranking #5,417 across 21,677 CEC solar panels (top 26.2%; higher than 73.8% of peers), Caterpillar Inc PVC455MB03H operates as a modern high-density residential and light-commercial module sitting 45.0 W above the 410.0 W Mono-c-Si median. Higher 49.8 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C). With strong 93.8% PTC-to-STC heat retention (#5,632 of 21,677), 18 panels occupy 409 sq ft and offset roughly $2,050/yr at average US rates (or $3,466/yr in California). Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes.
Where Does Caterpillar Inc PVC455MB03H Fall Across Listed CEC Models?
Plots Caterpillar Inc PVC455MB03H at 455.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define Caterpillar Inc PVC455MB03H?
Benchmarks Caterpillar Inc PVC455MB03H on STC wattage, thermal PTC/STC retention, and 21.56 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for Caterpillar Inc PVC455MB03H?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVC455MB03H by Caterpillar Inc.
Top 26.2% STC Output
455.0 W STC (+70.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
21.56% Aperture Efficiency
Power density 215.6 W/m2 (1.65 percentage points above 19.91% CEC median). PTC/STC ratio: 93.8% (rank #5,632).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 54.31 V at -10 C (597.4 V string) and 55.6 V at -20 C (10 max).
18 Panels = 8,190 W STC
Occupies 38.0 m2 (409 sq ft) producing 7,686 W PTC; NEC 690.8 OCPD floor is 18.17 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.8 * (1 + (-0.259/100) * (-10 - 25)) = 54.31 V | OCPD = 1.56 * 11.65 = 18.17 A
Inputs from CEC Modules.csv for Caterpillar Inc PVC455MB03H: Voc=49.8 V, beta_Voc=-0.259%/C, Isc=11.65 A, STC=455.0 W, Area=2.11 m2.
Result: 11 panels max on 600 V (597.4 V); 18 panels for 8 kW (409 sq ft).
What Are the Published CEC Specifications for Caterpillar Inc PVC455MB03H?
Laboratory test ratings recorded for Caterpillar Inc PVC455MB03H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 455.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 427.0 W (93.8% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.8 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.65 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 41.6 V / 10.93 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.259 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 21.56% (2.11 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Bifacial glass-glass |
How Many Caterpillar Inc PVC455MB03H Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (409 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVC455MB03H.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.37 kW | 318 sq ft | $1,594 | $2,696 |
| 8 kW Class | 18 | 8.19 kW | 409 sq ft | $2,050 | $3,466 |
| 10 kW Class | 22 | 10.01 kW | 500 sq ft | $2,505 | $4,236 |
Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?
Sibling wattage bins and frame colors grouped with Caterpillar Inc PVC455MB03H under Caterpillar Inc to prevent duplicate spec pages.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Caterpillar Inc PVC450MB03H | 450.0 W | 422.2 W | 49.6 V | 41.4 V | 21.33% |
| Caterpillar Inc PVC455MB03H | 455.0 W | 427.0 W | 49.8 V | 41.6 V | 21.56% |
How Many Caterpillar Inc PVC455MB03H Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for Caterpillar Inc PVC455MB03H (beta_Voc -0.259%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 55.6 V | 10 panels | 556.0 V | 17 panels |
| -10 C (14 F) | 54.31 V | 11 panels | 597.4 V | 18 panels |
| 0 C (32 F) | 53.02 V | 11 panels | 583.2 V | 18 panels |
| 25 C (77 F STC) | 49.8 V | 12 panels | 597.6 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC455MB03H?
Closest cross-brand CEC competitors to Caterpillar Inc PVC455MB03H matched near 455.0 W STC and 49.8 V Voc, led by CSI Solar Co Ltd CS3W-455MB-AG.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3W-455MB-AG CSI Solar Co Ltd |
455.0 W | Tie (0 W) | 49.3 V | 21.06% | 92.9% |
| Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF Boviet Solar Technology Co Ltd |
455.0 W | Tie (0 W) | 49.25 V | 20.4% | 93.8% |
| Boviet Solar Technology Co Ltd BVM6612M-455S-H-HC-BF-DG Boviet Solar Technology Co Ltd |
455.0 W | Tie (0 W) | 49.25 V | 20.4% | 93.8% |
| Bluesun Solar CoLtd BSM455M-72HBD Bluesun Solar CoLtd |
455.0 W | Tie (0 W) | 50.6 V | 20.97% | 92.7% |
What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC455MB03H?
Evaluate Caterpillar Inc PVC455MB03H (455.0 W STC, 49.8 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC455MB03H reaches 55.6 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 18 panels for an 8 kW build require 409 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 18 panels (409 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC455MB03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Caterpillar Inc PVC455MB03H 8 kW Residential Fit
Needs 18 modules (409 sq ft) with a 20 A string OCPD, offsetting ~$2,050/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare CSI Solar Co Ltd CS3W-455MB-AG.
Bifacial / High-Heat Roof Check
Glass-glass bifacial cells capture rear albedo reflection over light ground gravel or white membranes. Real-world output tracks 427.0 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Caterpillar Inc PVC455MB03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Caterpillar Inc PVC455MB03H panels fit on a 600 V winter solar string?
At -10 C (14 F), Caterpillar Inc PVC455MB03H cold Voc rises from 49.8 V to 54.31 V (beta_Voc -0.259%/C), capping a 600 V string at 11 panels (597.4 V).
How much roof area does an 8 kW array of Caterpillar Inc PVC455MB03H need?
An 8 kW DC system uses 18 Caterpillar Inc PVC455MB03H modules (8,190 W STC / 7,686 W PTC), covering roughly 409 sq ft and saving ~$2,050/yr at 18.54 c/kWh.
How does Caterpillar Inc PVC455MB03H compare against CSI Solar Co Ltd CS3W-455MB-AG?
Caterpillar Inc PVC455MB03H outputs 455.0 W STC (49.8 V Voc, rank #5,417 of 21,677), while CSI Solar Co Ltd CS3W-455MB-AG delivers 455.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)