Skip to main content
WireAndSun
Calculators
CEC PV Module

Caterpillar Inc PVC435MP03H — CEC Solar Module Specifications

Manufacturer: Caterpillar Inc Registry: CEC Verified Engineering Specification

Caterpillar Inc PVC435MP03H is a 435.0 W STC (407.1 W PTC) Mono-c-Si solar module ranking #6,850 of 21,677 CEC listings (top 33.5%; higher than 66.5% of peers). It delivers 20.52% efficiency, 48.7 V Voc at 25 C, and 53.22 V cold Voc at -10 C (11 panels max per 600 V string).

STC Wattage
435.0 W
PTC Wattage
407.1 W
Voc @ 25C
48.7 V
Efficiency
20.52%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Caterpillar Inc PVC435MP03H Compare Against Peer CEC Listings?

Engineering position of Caterpillar Inc PVC435MP03H (435.0 W STC) vs. CSI Solar Co Ltd CS3W-435P across 5,889 CEC Mono-c-Si solar modules.

Built with 72 Mono-c-Si cells, Caterpillar Inc PVC435MP03H pairs strong 93.6% PTC-to-STC heat retention (#6,726 of 21,677) with 48.7 V nominal Voc. An 8 kW residential build (8,265 W DC, 7,735 W PTC) saves ~$2,070/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer CSI Solar Co Ltd CS3W-435P offers a 435.0 W alternative.

Where Does Caterpillar Inc PVC435MP03H Fall Across Listed CEC Models?

Plots Caterpillar Inc PVC435MP03H at 435.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Caterpillar Inc PVC435MP03H (435.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCaterpillar Inc PV: 435.0 W

What Dataset Percentiles Define Caterpillar Inc PVC435MP03H?

Benchmarks Caterpillar Inc PVC435MP03H on STC wattage, thermal PTC/STC retention, and 20.52 aperture conversion efficiency against CEC peers.

Caterpillar Inc PVC435MP03H Engineering BenchmarksPercentile comparison of Caterpillar Inc PVC435MP03H wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage435.0 WPTC/STC Retention93.6%Module Efficiency20.52%

What Do the Dataset Ranks Show for Caterpillar Inc PVC435MP03H?

Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for Caterpillar Inc PVC435MP03H by Caterpillar Inc.

Rank #6,850 / 21,677

Top 33.5% STC Output

435.0 W STC (+50.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #8,460

20.52% Aperture Efficiency

Power density 205.2 W/m2 (0.61 percentage points above 19.91% CEC median). PTC/STC ratio: 93.6% (rank #6,726).

NEC 690.7 Limit

11 Panels Max @ -10 C (600 V)

Cold Voc reaches 53.22 V at -10 C (585.4 V string) and 54.51 V at -20 C (11 max).

8 kW Reference Array

19 Panels = 8,265 W STC

Occupies 40.3 m2 (434 sq ft) producing 7,735 W PTC; NEC 690.8 OCPD floor is 17.77 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 48.7 * (1 + (-0.265/100) * (-10 - 25)) = 53.22 V | OCPD = 1.56 * 11.39 = 17.77 A

Inputs from CEC Modules.csv for Caterpillar Inc PVC435MP03H: Voc=48.7 V, beta_Voc=-0.265%/C, Isc=11.39 A, STC=435.0 W, Area=2.12 m2.

Result: 11 panels max on 600 V (585.4 V); 19 panels for 8 kW (434 sq ft).

What Are the Published CEC Specifications for Caterpillar Inc PVC435MP03H?

Laboratory test ratings recorded for Caterpillar Inc PVC435MP03H (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVC435MP03H.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 435.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 407.1 W (93.6% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 48.7 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.39 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 40.9 V / 10.64 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.265 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 20.52% (2.12 m2) Array roof footprint density
Cell Count & Technology 72 cells (Mono-c-Si) Monofacial backsheet

How Many Caterpillar Inc PVC435MP03H Panels Build a 6 kW, 8 kW, or 10 kW Array?

Panel counts, roof square footage (434 sq ft at 8 kW), and estimated Year-1 electric bill offset for Caterpillar Inc PVC435MP03H.

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 14 6.09 kW 319 sq ft $1,524 $2,577
8 kW Class 19 8.27 kW 434 sq ft $2,070 $3,500
10 kW Class 23 10.01 kW 525 sq ft $2,505 $4,236

Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?

Sibling wattage bins and frame colors grouped with Caterpillar Inc PVC435MP03H under Caterpillar Inc to prevent duplicate spec pages.

Sibling CEC listings grouped into the Caterpillar Inc PVC435MP03H wattage tier to avoid duplicate 5W/trim datasheets.
Model VariantSTC (W)PTC (W)Voc (V)Vmp (V)Eff (%)
Caterpillar Inc PVC425MP03H 425.0 W 397.5 W 48.3 V 40.5 V 20.05%
Caterpillar Inc PVC430MP03H 430.0 W 402.3 W 48.5 V 40.7 V 20.28%
Caterpillar Inc PVC435MP03H 435.0 W 407.1 W 48.7 V 40.9 V 20.52%
Caterpillar Inc PVC440MP03H 440.0 W 411.9 W 48.9 V 41.1 V 20.75%
Caterpillar Inc PVC445MP03H 445.0 W 416.7 W 49.1 V 41.3 V 20.99%

How Many Caterpillar Inc PVC435MP03H Modules Fit in a Cold-Weather String?

Cold-weather Voc escalation for Caterpillar Inc PVC435MP03H (beta_Voc -0.265%/C) across 600 V residential and 1,000 V commercial inverters.

Computed from Voc=48.7V and beta_Voc=-0.265%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 54.51 V 11 panels 599.6 V 18 panels
-10 C (14 F) 53.22 V 11 panels 585.4 V 18 panels
0 C (32 F) 51.93 V 11 panels 571.2 V 19 panels
25 C (77 F STC) 48.7 V 12 panels 584.4 V 20 panels

Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC435MP03H?

Closest cross-brand CEC competitors to Caterpillar Inc PVC435MP03H matched near 435.0 W STC and 48.7 V Voc, led by CSI Solar Co Ltd CS3W-435P.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
CSI Solar Co Ltd CS3W-435P
CSI Solar Co Ltd
435.0 W Tie (0 W) 48.6 V 20.33% 92.4%
Boviet Solar Technology Co Ltd BVM6612M-435S-H-HC
Boviet Solar Technology Co Ltd
435.0 W Tie (0 W) 48.45 V 19.77% 93.7%
AXITEC AC-435MB/144V
AXITEC
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
Dehui Solar Power (Vietnam) CoLtd DH-M772F 435W
Dehui Solar Power (Vietnam) CoLtd
435.0 W Tie (0 W) 49.1 V 20.33% 92.6%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC435MP03H?

Evaluate Caterpillar Inc PVC435MP03H (435.0 W STC, 48.7 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC435MP03H reaches 54.51 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 19 panels for an 8 kW build require 434 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (434 sq ft) for an 8 kW array.
  • 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC435MP03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Caterpillar Inc PVC435MP03H 8 kW Residential Fit

Needs 19 modules (434 sq ft) with a 20 A string OCPD, offsetting ~$2,070/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare CSI Solar Co Ltd CS3W-435P.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 407.1 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVC435MP03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

What fuse or breaker size does NEC 690.8 require for Caterpillar Inc PVC435MP03H?

Multiplying Caterpillar Inc PVC435MP03H's 11.39 A short-circuit current by 1.56 equals 17.77 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.

Can Caterpillar Inc PVC435MP03H pair with microinverters instead of a 600 V string inverter?

Yes—if the microinverter DC input ceiling exceeds 53.22 V cold Voc at 14 F and handles 11.39 A Isc; string inverters cap Caterpillar Inc PVC435MP03H at 11 panels on 600 V.

Is Caterpillar Inc PVC435MP03H eligible for the 30% federal 25D solar credit in 2026?

No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of Caterpillar Inc PVC435MP03H rely on utility bill offset (~$2,070/yr at 8 kW) rather than 25D.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.