Caterpillar Inc PVC380MP03H is a 380.0 W STC (357.7 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 19.63% efficiency, 49.0 V Voc at 25 C, and 53.58 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 357.7 W
- Voc @ 25C
- 49.0 V
- Efficiency
- 19.63%
How Does Caterpillar Inc PVC380MP03H Compare Against Peer CEC Listings?
Solar engineering breakdown for Caterpillar Inc PVC380MP03H: PTC thermal retention, roof footprint, and cold Voc string bounds. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Measured at 380.0 W STC and 357.7 W PTC, Caterpillar Inc PVC380MP03H sits -5.0 W vs all-CEC median (below all-CEC median; higher than 47.6% of peers) among 21,677 listed modules. Power density reaches 196.3 W/m2 (0.28 percentage points below 19.91% CEC median). Higher 49.0 V open-circuit voltage caps 600 V residential strings at 11 panels at 14 F (-10 C), whereas 1,000 V commercial inverters handle up to 18 panels in series. Alternative peer Crossroads Solar Crossroads Solar 380 rates 380.0 W.
Where Does Caterpillar Inc PVC380MP03H Fall Across Listed CEC Models?
Distribution marker showing Caterpillar Inc PVC380MP03H (380.0 W) relative to the 385.0 W all-CEC solar panel median. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Dataset Percentiles Define Caterpillar Inc PVC380MP03H?
Dataset percentiles tracking Caterpillar Inc PVC380MP03H power output, thermal retention ratio, and aperture efficiency against 21,677 models. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
What Do the Dataset Ranks Show for Caterpillar Inc PVC380MP03H?
Benchmark highlights for Caterpillar Inc PVC380MP03H covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.63% Aperture Efficiency
Power density 196.3 W/m2 (0.28 percentage points below 19.91% CEC median). PTC/STC ratio: 94.1% (rank #4,203).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 53.58 V at -10 C (589.4 V string) and 54.89 V at -20 C (10 max).
22 Panels = 8,360 W STC
Occupies 42.6 m2 (458 sq ft) producing 7,869 W PTC; NEC 690.8 OCPD floor is 15.54 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 49.0 * (1 + (-0.267/100) * (-10 - 25)) = 53.58 V | OCPD = 1.56 * 9.96 = 15.54 A
Inputs from CEC Modules.csv for Caterpillar Inc PVC380MP03H: Voc=49.0 V, beta_Voc=-0.267%/C, Isc=9.96 A, STC=380.0 W, Area=1.936 m2.
Result: 11 panels max on 600 V (589.4 V); 22 panels for 8 kW (458 sq ft).
What Are the Published CEC Specifications for Caterpillar Inc PVC380MP03H?
Official CEC datasheet figures for Caterpillar Inc PVC380MP03H (Mono-c-Si) used in utility interconnection and permit reviews. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 357.7 W (94.1% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 49.0 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 9.96 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 40.6 V / 9.36 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.267 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.63% (1.936 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many Caterpillar Inc PVC380MP03H Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many Caterpillar Inc PVC380MP03H modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 333 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 458 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 563 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This Caterpillar Inc Series?
Consolidated Caterpillar Inc wattage variants sharing the Caterpillar Inc PVC380MP03H mechanical and cell layout. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| Caterpillar Inc PVC375MP03H | 375.0 W | 352.9 W | 48.8 V | 40.4 V | 19.37% |
| Caterpillar Inc PVC380MP03H | 380.0 W | 357.7 W | 49.0 V | 40.6 V | 19.63% |
| Caterpillar Inc PVC385MP03H | 385.0 W | 362.6 W | 49.2 V | 40.8 V | 19.89% |
How Many Caterpillar Inc PVC380MP03H Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on Caterpillar Inc PVC380MP03H (53.58 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.89 V | 10 panels | 548.9 V | 18 panels |
| -10 C (14 F) | 53.58 V | 11 panels | 589.4 V | 18 panels |
| 0 C (32 F) | 52.27 V | 11 panels | 575.0 V | 19 panels |
| 25 C (77 F STC) | 49.0 V | 12 panels | 588.0 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC380MP03H?
Competing CEC solar panels closest to Caterpillar Inc PVC380MP03H in nameplate wattage and Voc, starting with Crossroads Solar Crossroads Solar 380.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| CertainTeed CT380M10-02 CertainTeed |
380.0 W | Tie (0 W) | 47.94 V | 20.19% | 92.0% |
What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC380MP03H?
Evaluate Caterpillar Inc PVC380MP03H (380.0 W STC, 49.0 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC380MP03H reaches 54.89 V per panel—exceeding 10 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 458 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (458 sq ft).
- 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC380MP03H carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
Caterpillar Inc PVC380MP03H 8 kW Residential Fit
Needs 22 modules (458 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 10 panels (-20 C), or compare Crossroads Solar Crossroads Solar 380.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 357.7 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for Caterpillar Inc PVC380MP03H by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.
How many Caterpillar Inc PVC380MP03H panels fit on a 600 V winter solar string?
At -10 C (14 F), Caterpillar Inc PVC380MP03H cold Voc rises from 49.0 V to 53.58 V (beta_Voc -0.267%/C), capping a 600 V string at 11 panels (589.4 V).
How much roof area does an 8 kW array of Caterpillar Inc PVC380MP03H need?
An 8 kW DC system uses 22 Caterpillar Inc PVC380MP03H modules (8,360 W STC / 7,869 W PTC), covering roughly 458 sq ft and saving ~$2,092/yr at 18.54 c/kWh.
How does Caterpillar Inc PVC380MP03H compare against Crossroads Solar Crossroads Solar 380?
Caterpillar Inc PVC380MP03H outputs 380.0 W STC (49.0 V Voc, rank #11,043 of 21,677), while Crossroads Solar Crossroads Solar 380 delivers 380.0 W STC; both comply with 2026 NEC 690.7 string sizing rules.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)