CertainTeed CT380M10-02 is a 380.0 W STC (349.6 W PTC) Mono-c-Si solar module ranking #11,043 of 21,677 CEC listings (below all-CEC median; higher than 47.6% of peers). It delivers 20.19% efficiency, 47.94 V Voc at 25 C, and 52.65 V cold Voc at -10 C (11 panels max per 600 V string).
- STC Wattage
- 380.0 W
- PTC Wattage
- 349.6 W
- Voc @ 25C
- 47.94 V
- Efficiency
- 20.19%
How Does CertainTeed CT380M10-02 Compare Against Peer CEC Listings?
Engineering position of CertainTeed CT380M10-02 (380.0 W STC) vs. Auxin Solar AXN6M612T380 across 5,889 CEC Mono-c-Si solar modules.
Built with 72 Mono-c-Si cells, CertainTeed CT380M10-02 pairs strong 92.0% PTC-to-STC heat retention (#14,141 of 21,677) with 47.94 V nominal Voc. An 8 kW residential build (8,360 W DC, 7,691 W PTC) saves ~$2,092/yr at 18.54 c/kWh with zero federal 25D credit in 2026. Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Peer Auxin Solar AXN6M612T380 offers a 380.0 W alternative.
Where Does CertainTeed CT380M10-02 Fall Across Listed CEC Models?
Plots CertainTeed CT380M10-02 at 380.0 W STC across all 21,677 California Energy Commission photovoltaic modules relative to the 385.0 W median.
What Dataset Percentiles Define CertainTeed CT380M10-02?
Benchmarks CertainTeed CT380M10-02 on STC wattage, thermal PTC/STC retention, and 20.19 aperture conversion efficiency against CEC peers.
What Do the Dataset Ranks Show for CertainTeed CT380M10-02?
Key electrical performance ranks, roof area sizing, and NEC 690.7/690.8 design boundaries for CertainTeed CT380M10-02 by CertainTeed.
380.0 W STC · Higher Than 47.6%
380.0 W STC (-5.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.19% Aperture Efficiency
Power density 201.9 W/m2 (0.28 percentage points above 19.91% CEC median). PTC/STC ratio: 92.0% (rank #14,141).
11 Panels Max @ -10 C (600 V)
Cold Voc reaches 52.65 V at -10 C (579.1 V string) and 54.0 V at -20 C (11 max).
22 Panels = 8,360 W STC
Occupies 41.4 m2 (446 sq ft) producing 7,691 W PTC; NEC 690.8 OCPD floor is 16.15 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 47.94 * (1 + (-0.281/100) * (-10 - 25)) = 52.65 V | OCPD = 1.56 * 10.35 = 16.15 A
Inputs from CEC Modules.csv for CertainTeed CT380M10-02: Voc=47.94 V, beta_Voc=-0.281%/C, Isc=10.35 A, STC=380.0 W, Area=1.882 m2.
Result: 11 panels max on 600 V (579.1 V); 22 panels for 8 kW (446 sq ft).
What Are the Published CEC Specifications for CertainTeed CT380M10-02?
Laboratory test ratings recorded for CertainTeed CT380M10-02 (Mono-c-Si) in the official California Energy Commission NREL SAM equipment catalog.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 380.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 349.6 W (92.0% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 47.94 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.35 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 38.9 V / 9.8 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.281 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.19% (1.882 m2) | Array roof footprint density |
| Cell Count & Technology | 72 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CT380M10-02 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Panel counts, roof square footage (446 sq ft at 8 kW), and estimated Year-1 electric bill offset for CertainTeed CT380M10-02.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 16 | 6.08 kW | 324 sq ft | $1,522 | $2,573 |
| 8 kW Class | 22 | 8.36 kW | 446 sq ft | $2,092 | $3,538 |
| 10 kW Class | 27 | 10.26 kW | 547 sq ft | $2,568 | $4,342 |
Which Sibling Wattage & Trim Variants Belong to This CertainTeed Series?
Sibling wattage bins and frame colors grouped with CertainTeed CT380M10-02 under CertainTeed to prevent duplicate spec pages. Homeowners and permit reviewers can filter tables below to benchmark specific ratings, wiring ages, and code allowances side by side.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CertainTeed CT375M10-02 | 375.0 W | 344.9 W | 47.85 V | 38.9 V | 19.93% |
| CertainTeed CT380M10-02 | 380.0 W | 349.6 W | 47.94 V | 38.9 V | 20.19% |
How Many CertainTeed CT380M10-02 Modules Fit in a Cold-Weather String?
Cold-weather Voc escalation for CertainTeed CT380M10-02 (beta_Voc -0.281%/C) across 600 V residential and 1,000 V commercial inverters.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 54.0 V | 11 panels | 594.0 V | 18 panels |
| -10 C (14 F) | 52.65 V | 11 panels | 579.1 V | 18 panels |
| 0 C (32 F) | 51.31 V | 11 panels | 564.4 V | 19 panels |
| 25 C (77 F STC) | 47.94 V | 12 panels | 575.3 V | 20 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CT380M10-02?
Closest cross-brand CEC competitors to CertainTeed CT380M10-02 matched near 380.0 W STC and 47.94 V Voc, led by Auxin Solar AXN6M612T380.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Auxin Solar AXN6M612T380 Auxin Solar |
380.0 W | Tie (0 W) | 47.94 V | 19.58% | 91.9% |
| Bluesun Solar Energy Tech CoLtd BSM380M-72 Bluesun Solar Energy Tech CoLtd |
380.0 W | Tie (0 W) | 48.67 V | 19.59% | 92.0% |
| Caterpillar Inc PVC380MP03H Caterpillar Inc |
380.0 W | Tie (0 W) | 49.0 V | 19.63% | 94.1% |
| Crossroads Solar Crossroads Solar 380 Crossroads Solar |
380.0 W | Tie (0 W) | 49.0 V | 18.63% | 92.2% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CT380M10-02?
Evaluate CertainTeed CT380M10-02 (380.0 W STC, 47.94 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CT380M10-02 reaches 54.0 V per panel—exceeding 11 panels in series voids 600 V inverter warranties.
- Footprint constraint: 22 panels for an 8 kW build require 446 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 22 panels (446 sq ft).
- 2026 tax credit baseline: cash residential installs of CertainTeed CT380M10-02 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CT380M10-02 8 kW Residential Fit
Needs 22 modules (446 sq ft) with a 20 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 11 panels (-10 C) or 11 panels (-20 C), or compare Auxin Solar AXN6M612T380.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 349.6 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CT380M10-02 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What fuse or breaker size does NEC 690.8 require for CertainTeed CT380M10-02?
Multiplying CertainTeed CT380M10-02's 10.35 A short-circuit current by 1.56 equals 16.15 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker. Check local building department permit requirements for CertainTeed CT380M10-02 before finalizing component orders.
Can CertainTeed CT380M10-02 pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 52.65 V cold Voc at 14 F and handles 10.35 A Isc; string inverters cap CertainTeed CT380M10-02 at 11 panels on 600 V.
Is CertainTeed CT380M10-02 eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CertainTeed CT380M10-02 rely on utility bill offset (~$2,092/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)