CertainTeed CTM10440HC11-06 is a 440.0 W STC (412.3 W PTC) Mono-c-Si solar module ranking #6,418 of 21,677 CEC listings (top 31.6%; higher than 68.4% of peers). It delivers 20.37% efficiency, 41.02 V Voc at 25 C, and 44.93 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 440.0 W
- PTC Wattage
- 412.3 W
- Voc @ 25C
- 41.02 V
- Efficiency
- 20.37%
How Does CertainTeed CTM10440HC11-06 Compare Against Peer CEC Listings?
CEC rank, roof space requirements, and NEC 690.7/690.8 limits for CertainTeed CTM10440HC11-06 (Mono-c-Si) residential solar systems. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.
Homeowners evaluating CertainTeed CTM10440HC11-06 need 14 panels for 6 kW or 19 panels (442 sq ft) for an 8 kW array—well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array. Under NEC 690.7(A), beta_Voc (-0.272%/C) pushes open-circuit voltage to 44.93 V at 14 F and 46.04 V at -4 F. Monofacial backsheet sealing targets flush dark shingle rooftop mounts.
Where Does CertainTeed CTM10440HC11-06 Fall Across Listed CEC Models?
Comparison of CertainTeed CTM10440HC11-06 (440.0 W STC) against all 21,677 California Energy Commission certified photovoltaic modules. Always verify current state NEC adoption cycles, local utility interconnection tariffs, and panel busbar ratings before pulling project permits.
What Dataset Percentiles Define CertainTeed CTM10440HC11-06?
Relative ranking of CertainTeed CTM10440HC11-06 across nameplate watts, 93.7% PTC thermal ratio, and module aperture efficiency. Inspect manufacturer nameplate documentation, UL listing boundaries, and utility rate schedules closely before ordering electrical hardware.
What Do the Dataset Ranks Show for CertainTeed CTM10440HC11-06?
Summary of CertainTeed CTM10440HC11-06 output rank, 8 kW array size (19 panels), efficiency rating, and 600 V string limit.
Top 31.6% STC Output
440.0 W STC (+55.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
20.37% Aperture Efficiency
Power density 203.7 W/m2 (0.46 percentage points above 19.91% CEC median). PTC/STC ratio: 93.7% (rank #6,162).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 44.93 V at -10 C (584.1 V string) and 46.04 V at -20 C (13 max).
19 Panels = 8,360 W STC
Occupies 41.0 m2 (442 sq ft) producing 7,834 W PTC; NEC 690.8 OCPD floor is 21.42 A (25 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 41.02 * (1 + (-0.272/100) * (-10 - 25)) = 44.93 V | OCPD = 1.56 * 13.73 = 21.42 A
Inputs from CEC Modules.csv for CertainTeed CTM10440HC11-06: Voc=41.02 V, beta_Voc=-0.272%/C, Isc=13.73 A, STC=440.0 W, Area=2.16 m2.
Result: 13 panels max on 600 V (584.1 V); 19 panels for 8 kW (442 sq ft).
What Are the Published CEC Specifications for CertainTeed CTM10440HC11-06?
Complete CEC test sheet for CertainTeed CTM10440HC11-06 including Isc (13.73 A), Voc (41.02 V), and thermal temperature coefficients.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 440.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 412.3 W (93.7% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 41.02 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 13.73 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.72 V / 13.05 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.272 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 20.37% (2.16 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many CertainTeed CTM10440HC11-06 Panels Build a 6 kW, 8 kW, or 10 kW Array?
Residential array count and annual electric bill savings at 18.54 c/kWh US avg vs. California tariffs using CertainTeed CTM10440HC11-06.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 14 | 6.16 kW | 326 sq ft | $1,542 | $2,607 |
| 8 kW Class | 19 | 8.36 kW | 442 sq ft | $2,092 | $3,538 |
| 10 kW Class | 23 | 10.12 kW | 535 sq ft | $2,533 | $4,283 |
How Many CertainTeed CTM10440HC11-06 Modules Fit in a Cold-Weather String?
Verify freezing-morning voltage rise for CertainTeed CTM10440HC11-06 (41.02 V STC) before wiring 600 V or 1,000 V strings.
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 46.04 V | 13 panels | 598.5 V | 21 panels |
| -10 C (14 F) | 44.93 V | 13 panels | 584.1 V | 22 panels |
| 0 C (32 F) | 43.81 V | 13 panels | 569.5 V | 22 panels |
| 25 C (77 F STC) | 41.02 V | 14 panels | 574.3 V | 24 panels |
Which Cross-Brand Solar Modules Compare Closest to CertainTeed CTM10440HC11-06?
Four comparable CEC modules such as Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV (440.0 W) for side-by-side solar quote checks.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV Changzhou EGing Photovoltaic Technology Co Ltd |
440.0 W | Tie (0 W) | 41.0 V | 20.37% | 93.7% |
| Elin Energy (Sirius PV) ELNSM60M-HC-440 Elin Energy (Sirius PV) |
440.0 W | Tie (0 W) | 41.12 V | 20.47% | 94.2% |
| Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos1 Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
| Aptos Solar Technology LLC DNA-120-MF10-440W-USAptos2 Aptos Solar Technology LLC |
440.0 W | Tie (0 W) | 41.18 V | 20.56% | 94.3% |
What Are the Design Limits and Best-Fit Uses for CertainTeed CTM10440HC11-06?
Evaluate CertainTeed CTM10440HC11-06 (440.0 W STC, 41.02 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CertainTeed CTM10440HC11-06 reaches 46.04 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 19 panels for an 8 kW build require 442 sq ft of unshaded roof plane — well-proportioned for residential pitched roofs needing 19 panels (442 sq ft) for an 8 kW array.
- 2026 tax credit baseline: cash residential installs of CertainTeed CTM10440HC11-06 carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CertainTeed CTM10440HC11-06 8 kW Residential Fit
Needs 19 modules (442 sq ft) with a 25 A string OCPD, offsetting ~$2,092/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 412.3 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CertainTeed CTM10440HC11-06 by CertainTeed grounded in CEC test data and NEC 690.7/690.8 limits. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
Why is CertainTeed CTM10440HC11-06 PTC wattage (412.3 W) lower than STC (440.0 W)?
Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 412.3 W PTC (93.7% retention) across CertainTeed CTM10440HC11-06's 2.16 m2 aperture.
Who should skip CertainTeed CTM10440HC11-06 on a complex residential roof?
Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 19 CertainTeed CTM10440HC11-06 panels (442 sq ft) leave unusable roof gaps vs. Changzhou EGing Photovoltaic Technology Co Ltd EG-440M60-HLV.
What is the 1,000 V commercial string limit for CertainTeed CTM10440HC11-06?
On 1,000 V commercial inverters at -10 C (44.93 V cold Voc), CertainTeed CTM10440HC11-06 fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting CertainTeed CTM10440HC11-06.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)