Registry: California Energy Commission (CEC) Verified: 2026-11-26

Caterpillar Inc holds 12 verified California Energy Commission (CEC) certifications including 12 module series (112–455W PV). Caterpillar Inc carries 12 module series ranging from 112 W to 455 W STC (median 375 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si, Thin Film).

Manufacturer
Caterpillar Inc
PV Module Series
12
Listed Inverters
0
Output Range
112–455W PV
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Do Caterpillar Inc Solar Specifications Compare Across the CEC Catalog?

How Caterpillar Inc residential and commercial solar models stack up on aperture efficiency, winter voltage margin, and grid-interconnection readiness.

When specifying Caterpillar Inc for older US residential panels, engineers balance nameplate wattage against main busbar 120% backfeed ceilings (NEC 705.12). Caterpillar Inc carries 12 module series ranging from 112 W to 455 W STC (median 375 W vs 385 W CEC fleet median; 19.9% median aperture efficiency, cell architecture Mono-c-Si, Thin Film). No active CPSC electrical recalls match Caterpillar Inc in our federal recall archive as of 2026.

Which Caterpillar Inc PV Module Series Are CEC Certified? (12)

Certified Caterpillar Inc PV module specifications below include exact variant counts so installers can match permitted plan sets to CEC datasheets.

Deduplicated CEC photovoltaic module series for Caterpillar Inc.
Module Series STC (W) PTC (W) Voc (V) Eff (%) Variants
Caterpillar Inc PVC455MB03H 455.0 427.0 49.8 21.56 2
Caterpillar Inc PVC455MP03H 455.0 426.3 49.5 21.46 2
Caterpillar Inc PVC435MB03H 435.0 407.8 49.1 20.62 5
Caterpillar Inc PVC435MP03H 435.0 407.1 48.7 20.52 5
Caterpillar Inc PVC380MP03 380.0 355.2 49.03 20.21 2
Caterpillar Inc PVC380MP03H 380.0 357.7 49.0 19.63 3
Caterpillar Inc PVC370MP03H 370.0 348.1 48.6 19.11 2
Caterpillar Inc PVC365MP03 365.0 340.8 48.13 19.41 3
Caterpillar Inc PVC365MP03HA 365.0 341.1 41.0 20.62 4
Caterpillar Inc PVC345MP03HA 345.0 322.0 40.2 19.49 1
Caterpillar Inc PVT112 112.5 104.5 87.7 15.62 6
Caterpillar Inc PVT112 ARC 112.5 104.5 87.7 15.62 6
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc Solar Hardware?

Evaluate Caterpillar Inc CEC certifications (112–455W PV), winter voltage limits, and main panel 120% backfeed constraints before finalizing your equipment contract.

  • Caterpillar Inc certifies only photovoltaic modules on this CEC list; installers must pair them with a separate UL 1741 SA/SB grid-support inverter verified for NEC 690.7 winter Voc.
  • Constrained roofs: Caterpillar Inc's median module aperture efficiency (19.9%) sits below the 19.91% CEC fleet median, requiring slightly more square feet per kilowatt.

Caterpillar Inc Module + Third-Party Inverter

Pair Caterpillar Inc modules (112–455W PV) with microinverters or string inverters rated above local cold-weather Voc.

Unshaded Roofs & Ground Mounts

Focus on dollar-per-watt cash bids below $2.95/W since Section 25D residential tax credits expired after 2025.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Common permitting, cold-weather string sizing, and warranty inspection questions homeowners ask before approving Caterpillar Inc solar equipment. Cross-check local Authority Having Jurisdiction amendments and serving utility net-metering terms before finalizing project sizing.

How many Caterpillar Inc solar models are verified on the CEC list?

Our CEC archive indexes 12 Caterpillar Inc equipment records (12 module series and 0 inverter models) spanning 112–455W PV. Check local building department permit requirements for Caterpillar Inc before finalizing component orders.

What should homeowners check before approving Caterpillar Inc equipment on a solar quote?

Verify the exact CEC model string on your utility interconnection form, confirm cold-weather NEC 690.7 string Voc stays below inverter Vdcmax, and verify NEC 705.12 120% busbar capacity on your main breaker panel.

How efficient are Caterpillar Inc solar panels compared to CEC averages?

Across listed series, Caterpillar Inc modules show a median aperture efficiency of 19.9% versus 19.91% across all certified CEC photovoltaic panels. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Caterpillar Inc.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. CEC Solar Equipment List — Grid-Support Inverters (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  3. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)
  4. CPSC SaferProducts Recall Database (Panels, Breakers, Generators, Solar) — U.S. Consumer Product Safety Commission (CPSC), 2026-11 (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.