Caterpillar Inc PVC345MP03HA — CEC Solar Module Specifications

Manufacturer: Caterpillar Inc Registry: CEC Verified Engineering Specification

Caterpillar Inc PVC345MP03HA is a 345.0 W STC (322.0 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 19.49% efficiency, 40.2 V Voc at 25 C, and 43.94 V cold Voc at -10 C (13 panels max per 600 V string).

STC Wattage
345.0 W
PTC Wattage
322.0 W
Voc @ 25C
40.2 V
Efficiency
19.49%
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit
Wall-mounted residential hybrid solar inverter and modular battery cabinet piped with galvanized EMT conduit

How Does Caterpillar Inc PVC345MP03HA Compare Against Peer CEC Listings?

How Caterpillar Inc Caterpillar Inc PVC345MP03HA handles rooftop heat (322.0 W PTC), 8 kW sizing, and cold winter string voltage.

For NEC string engineering, Caterpillar Inc PVC345MP03HA exhibits 11.06 A short-circuit current, requiring a 17.25 A (156%) conductor rating and 20 A OCPD under NEC 690.8. Ranked #13,309 of 21,677 (65.0 W below the 410.0 W Mono-c-Si median), this compact residential or specialty off-grid module covers 42.5 m2 for an 8 kW system (29 panels for 10 kW). Mid-range 40.2 V open-circuit voltage allows up to 13 panels per 600 V string at 14 F.

Where Does Caterpillar Inc PVC345MP03HA Fall Across Listed CEC Models?

Where Caterpillar Inc PVC345MP03HA (345.0 W) sits inside the 21,677-panel CEC STC wattage curve relative to the 385.0 W median.

STC Power Distribution Across 21,677 CEC Solar ModulesMarks where Caterpillar Inc PVC345MP03HA (345.0 W STC) stands relative to CEC photovoltaic modules. 18-79 W STC: 68 entries1879-140 W STC: 170 entries140-202 W STC: 413 entries202-263 W STC: 1,883 entries202263-325 W STC: 4,202 entries325-386 W STC: 4,219 entries386-448 W STC: 4,695 entries386448-509 W STC: 1,584 entries509-571 W STC: 2,290 entries571-632 W STC: 1,371 entries571632-694 W STC: 534 entries694-755 W STC: 248 entries694Median 385 W STCCaterpillar Inc PV: 345.0 W

What Dataset Percentiles Define Caterpillar Inc PVC345MP03HA?

Percentile placement of Caterpillar Inc PVC345MP03HA across power density (194.9 W/m2), thermal retention, and nameplate STC wattage.

Caterpillar Inc PVC345MP03HA Engineering BenchmarksPercentile comparison of Caterpillar Inc PVC345MP03HA wattage, thermal retention, and efficiency. 0% (Low)50% Median100% (Top)STC Wattage345.0 WPTC/STC Retention93.3%Module Efficiency19.49%

What Do the Dataset Ranks Show for Caterpillar Inc PVC345MP03HA?

Four critical engineering numbers homeowners and solar installers check first when reviewing Caterpillar Inc PVC345MP03HA specifications. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.

Rank #13,309 / 21,677

345.0 W STC · Higher Than 37.4%

345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.

Eff #12,236

19.49% Aperture Efficiency

Power density 194.9 W/m2 (0.42 percentage points below 19.91% CEC median). PTC/STC ratio: 93.3% (rank #8,323).

NEC 690.7 Limit

13 Panels Max @ -10 C (600 V)

Cold Voc reaches 43.94 V at -10 C (571.2 V string) and 45.01 V at -20 C (13 max).

8 kW Reference Array

24 Panels = 8,280 W STC

Occupies 42.5 m2 (457 sq ft) producing 7,728 W PTC; NEC 690.8 OCPD floor is 17.25 A (20 A breaker).

NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula

Voc_cold = 40.2 * (1 + (-0.266/100) * (-10 - 25)) = 43.94 V | OCPD = 1.56 * 11.06 = 17.25 A

Inputs from CEC Modules.csv for Caterpillar Inc PVC345MP03HA: Voc=40.2 V, beta_Voc=-0.266%/C, Isc=11.06 A, STC=345.0 W, Area=1.77 m2.

Result: 13 panels max on 600 V (571.2 V); 24 panels for 8 kW (457 sq ft).

What Are the Published CEC Specifications for Caterpillar Inc PVC345MP03HA?

Verified electrical STC and PTC ratings, open-circuit voltage, short-circuit current, and physical area published for Caterpillar Inc PVC345MP03HA.

Official California Energy Commission (NREL SAM) test parameters for Caterpillar Inc PVC345MP03HA.
ParameterMeasured / Listed ValueEngineering Significance
Nameplate Power (STC) 345.0 W Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell)
Real-World Output (PTC) 322.0 W (93.3% STC) PVUSA Test Conditions rating used for utility interconnection
Open-Circuit Voltage (Voc) 40.2 V Primary cold-weather string sizing limit under NEC 690.7
Short-Circuit Current (Isc) 11.06 A Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8
Max Power Voltage / Current 34.2 V / 10.09 A Inverter MPPT operating window alignment
Voc Temp Coefficient (beta_Voc) -0.266 %/C Negative slope governing voltage rise below 25C
Module Efficiency & Area 19.49% (1.77 m2) Array roof footprint density
Cell Count & Technology 60 cells (Mono-c-Si) Monofacial backsheet

How Many Caterpillar Inc PVC345MP03HA Panels Build a 6 kW, 8 kW, or 10 kW Array?

Compare 6 kW, 8 kW, and 10 kW array footprints and Year-1 utility savings using Caterpillar Inc PVC345MP03HA (345.0 W).

Estimated panel count, roof square footage, and Year-1 bill offset across low, average, and high US utility tariffs (0% 25D).
Target ArrayPanelsActual DCRoof AreaUS Avg ($/yr)CA High ($/yr)
6 kW Class 18 6.21 kW 343 sq ft $1,554 $2,628
8 kW Class 24 8.28 kW 457 sq ft $2,072 $3,504
10 kW Class 29 10.01 kW 553 sq ft $2,505 $4,236

How Many Caterpillar Inc PVC345MP03HA Modules Fit in a Cold-Weather String?

Maximum series module counts for Caterpillar Inc PVC345MP03HA from 25 C down to -20 C (-4 F) under NEC 690.7.

Computed from Voc=40.2V and beta_Voc=-0.266%/C across design ambient temperatures.
Ambient Min TempCold Voc / PanelMax Panels (600 V)600 V String VocMax Panels (1000 V)
-20 C (-4 F) 45.01 V 13 panels 585.1 V 22 panels
-10 C (14 F) 43.94 V 13 panels 571.2 V 22 panels
0 C (32 F) 42.87 V 13 panels 557.3 V 23 panels
25 C (77 F STC) 40.2 V 14 panels 562.8 V 24 panels

Which Cross-Brand Solar Modules Compare Closest to Caterpillar Inc PVC345MP03HA?

Alternative CEC solar modules from competing brands near Caterpillar Inc PVC345MP03HA (345.0 W), including ELITE Solar ET-M660BH345BB. All figures trace directly to published federal energy filings, state electrical boards, CEC datasheets, and NFPA 70 NEC tables.

Nearest CEC-listed competing brands by STC power and open-circuit voltage.
Alternative ModuleSTC (W)Delta vs ThisVoc (V)Eff (%)PTC/STC
ELITE Solar ET-M660BH345BB
ELITE Solar
345.0 W Tie (0 W) 39.9 V 19.17% 93.5%
CSI Solar Co Ltd CS3L-345MS
CSI Solar Co Ltd
345.0 W Tie (0 W) 39.8 V 19.27% 92.9%
DualSun SAS DualSun 340M-120-00
DualSun SAS
340.0 W -5.0 W 40.1 V 18.78% 93.2%
Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}
Aptos Solar Technology LLC
335.0 W -10.0 W 40.44 V 19.85% 90.8%
What to Check & Best-Fit Scenarios

What Are the Design Limits and Best-Fit Uses for Caterpillar Inc PVC345MP03HA?

Evaluate Caterpillar Inc PVC345MP03HA (345.0 W STC, 40.2 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.

  • Winter overvoltage boundary: at -20 C (-4 F), Caterpillar Inc PVC345MP03HA reaches 45.01 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
  • Footprint constraint: 24 panels for an 8 kW build require 457 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (457 sq ft).
  • 2026 tax credit baseline: cash residential installs of Caterpillar Inc PVC345MP03HA carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.

Caterpillar Inc PVC345MP03HA 8 kW Residential Fit

Needs 24 modules (457 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.

Cold-Climate String Design (-10 C / -20 C)

Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare ELITE Solar ET-M660BH345BB.

Bifacial / High-Heat Roof Check

Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 322.0 W PTC.

Which Homeowner Electrical & Solar Questions Come Up Most Often?

Technical answers for Caterpillar Inc PVC345MP03HA by Caterpillar Inc grounded in CEC test data and NEC 690.7/690.8 limits.

Why is Caterpillar Inc PVC345MP03HA PTC wattage (322.0 W) lower than STC (345.0 W)?

Laboratory STC tests at 25 C cell temperature, whereas real rooftop heat lowers voltage to 322.0 W PTC (93.3% retention) across Caterpillar Inc PVC345MP03HA's 1.77 m2 aperture.

Who should skip Caterpillar Inc PVC345MP03HA on a complex residential roof?

Homes with chopped dormers or heavy chimney shade should compare smaller modules or microinverters if 24 Caterpillar Inc PVC345MP03HA panels (457 sq ft) leave unusable roof gaps vs. ELITE Solar ET-M660BH345BB.

What is the 1,000 V commercial string limit for Caterpillar Inc PVC345MP03HA?

On 1,000 V commercial inverters at -10 C (43.94 V cold Voc), Caterpillar Inc PVC345MP03HA fits up to 22 panels per series string. Review current municipal Authority Having Jurisdiction (AHJ) code amendments affecting Caterpillar Inc PVC345MP03HA.

Sources

  1. CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
  2. NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)

Which Regional Electrical & Panel Upgrade Metros Compare Closest?

Check Wiring & Solar Numbers Before Getting Quotes

Verify panel capacity for solar, electrical box space, proper wire gauge for EV chargers, and 2026 home solar payback using local utility rates.

Verify State-Licensed Electricians & Safety Recalls

Look up active state electrician licenses (TX, WA, CO, OR, DE), check local power-outage history, and inspect federal product recall notices.