ELITE Solar ET-M660BH345BB is a 345.0 W STC (322.5 W PTC) Mono-c-Si solar module ranking #13,309 of 21,677 CEC listings (below all-CEC median; higher than 37.4% of peers). It delivers 19.17% efficiency, 39.9 V Voc at 25 C, and 43.57 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 345.0 W
- PTC Wattage
- 322.5 W
- Voc @ 25C
- 39.9 V
- Efficiency
- 19.17%
How Does ELITE Solar ET-M660BH345BB Compare Against Peer CEC Listings?
Solar engineering breakdown for ELITE Solar ET-M660BH345BB: PTC thermal retention, roof footprint, and cold Voc string bounds. Review related calculators, peer benchmarks, and source citations below to validate design assumptions for your electrical service.
Across 5,889 Mono-c-Si listings from ELITE Solar and peers, ELITE Solar ET-M660BH345BB stands 65.0 W below the 410.0 W Mono-c-Si median and strong 93.5% PTC-to-STC heat retention (#7,159 of 21,677). Sizing 6 kW (18 panels) to 10 kW (29 panels) yields $1,554-$2,505/yr in baseline US bill offset. Lower 39.9 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does ELITE Solar ET-M660BH345BB Fall Across Listed CEC Models?
Distribution marker showing ELITE Solar ET-M660BH345BB (345.0 W) relative to the 385.0 W all-CEC solar panel median. Compare thermal ratings, overcurrent protection caps, and continuous load headroom carefully before expanding an existing home service panel.
What Dataset Percentiles Define ELITE Solar ET-M660BH345BB?
Dataset percentiles tracking ELITE Solar ET-M660BH345BB power output, thermal retention ratio, and aperture efficiency against 21,677 models. Use these verified dataset benchmarks alongside a licensed electrician load calculation to compare residential upgrade bids with confidence.
What Do the Dataset Ranks Show for ELITE Solar ET-M660BH345BB?
Benchmark highlights for ELITE Solar ET-M660BH345BB covering STC output, efficiency, 8 kW footprint, and OCPD breaker size. Regional housing vintage, storm hazard frequency, and wholesale utility prices directly govern residential upgrade payback across jurisdictions.
345.0 W STC · Higher Than 37.4%
345.0 W STC (-40.0 W vs all-CEC median) vs 410.0 W Mono-c-Si median.
19.17% Aperture Efficiency
Power density 191.7 W/m2 (0.74 percentage points below 19.91% CEC median). PTC/STC ratio: 93.5% (rank #7,159).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.57 V at -10 C (566.4 V string) and 44.62 V at -20 C (13 max).
24 Panels = 8,280 W STC
Occupies 43.2 m2 (465 sq ft) producing 7,740 W PTC; NEC 690.8 OCPD floor is 17.24 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.9 * (1 + (-0.263/100) * (-10 - 25)) = 43.57 V | OCPD = 1.56 * 11.05 = 17.24 A
Inputs from CEC Modules.csv for ELITE Solar ET-M660BH345BB: Voc=39.9 V, beta_Voc=-0.263%/C, Isc=11.05 A, STC=345.0 W, Area=1.8 m2.
Result: 13 panels max on 600 V (566.4 V); 24 panels for 8 kW (465 sq ft).
What Are the Published CEC Specifications for ELITE Solar ET-M660BH345BB?
Official CEC datasheet figures for ELITE Solar ET-M660BH345BB (Mono-c-Si) used in utility interconnection and permit reviews. Every reported metric links directly to federal public records or state regulatory filings with zero paid contractor placements.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 345.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 322.5 W (93.5% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.9 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 11.05 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 33.4 V / 10.34 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.263 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 19.17% (1.8 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Mono-c-Si) | Monofacial backsheet |
How Many ELITE Solar ET-M660BH345BB Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many ELITE Solar ET-M660BH345BB modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.21 kW | 349 sq ft | $1,554 | $2,628 |
| 8 kW Class | 24 | 8.28 kW | 465 sq ft | $2,072 | $3,504 |
| 10 kW Class | 29 | 10.01 kW | 562 sq ft | $2,505 | $4,236 |
How Many ELITE Solar ET-M660BH345BB Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on ELITE Solar ET-M660BH345BB (43.57 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.62 V | 13 panels | 580.1 V | 22 panels |
| -10 C (14 F) | 43.57 V | 13 panels | 566.4 V | 22 panels |
| 0 C (32 F) | 42.52 V | 14 panels | 595.3 V | 23 panels |
| 25 C (77 F STC) | 39.9 V | 15 panels | 598.5 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to ELITE Solar ET-M660BH345BB?
Competing CEC solar panels closest to ELITE Solar ET-M660BH345BB in nameplate wattage and Voc, starting with CSI Solar Co Ltd CS3L-345MS.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-345MS CSI Solar Co Ltd |
345.0 W | Tie (0 W) | 39.8 V | 19.27% | 92.9% |
| Caterpillar Inc PVC345MP03HA Caterpillar Inc |
345.0 W | Tie (0 W) | 40.2 V | 19.49% | 93.3% |
| DualSun SAS DualSun 340M-120-00 DualSun SAS |
340.0 W | -5.0 W | 40.1 V | 18.78% | 93.2% |
| CSI Solar Co Ltd CS3L-335P CSI Solar Co Ltd |
335.0 W | -10.0 W | 39.4 V | 18.72% | 93.2% |
What Are the Design Limits and Best-Fit Uses for ELITE Solar ET-M660BH345BB?
Evaluate ELITE Solar ET-M660BH345BB (345.0 W STC, 39.9 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), ELITE Solar ET-M660BH345BB reaches 44.62 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 465 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (465 sq ft).
- 2026 tax credit baseline: cash residential installs of ELITE Solar ET-M660BH345BB carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
ELITE Solar ET-M660BH345BB 8 kW Residential Fit
Needs 24 modules (465 sq ft) with a 20 A string OCPD, offsetting ~$2,072/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare CSI Solar Co Ltd CS3L-345MS.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 322.5 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for ELITE Solar ET-M660BH345BB by ELITE Solar grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for ELITE Solar ET-M660BH345BB?
Multiplying ELITE Solar ET-M660BH345BB's 11.05 A short-circuit current by 1.56 equals 17.24 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can ELITE Solar ET-M660BH345BB pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.57 V cold Voc at 14 F and handles 11.05 A Isc; string inverters cap ELITE Solar ET-M660BH345BB at 13 panels on 600 V.
Is ELITE Solar ET-M660BH345BB eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of ELITE Solar ET-M660BH345BB rely on utility bill offset (~$2,072/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)