CSI Solar Co Ltd CS3L-335P is a 335.0 W STC (312.1 W PTC) Multi-c-Si solar module ranking #13,844 of 21,677 CEC listings (below all-CEC median; higher than 34.7% of peers). It delivers 18.72% efficiency, 39.4 V Voc at 25 C, and 43.11 V cold Voc at -10 C (13 panels max per 600 V string).
- STC Wattage
- 335.0 W
- PTC Wattage
- 312.1 W
- Voc @ 25C
- 39.4 V
- Efficiency
- 18.72%
How Does CSI Solar Co Ltd CS3L-335P Compare Against Peer CEC Listings?
Solar engineering breakdown for CSI Solar Co Ltd CS3L-335P: PTC thermal retention, roof footprint, and cold Voc string bounds.
Across 1,407 Multi-c-Si listings from CSI Solar Co Ltd and peers, CSI Solar Co Ltd CS3L-335P stands 56.2 W above the 278.8 W Multi-c-Si median and strong 93.2% PTC-to-STC heat retention (#8,924 of 21,677). Sizing 6 kW (18 panels) to 10 kW (30 panels) yields $1,509-$2,515/yr in baseline US bill offset. Lower 39.4 V string voltage fits 13 panels in series at 14 F and pairs easily with microinverters.
Where Does CSI Solar Co Ltd CS3L-335P Fall Across Listed CEC Models?
Distribution marker showing CSI Solar Co Ltd CS3L-335P (335.0 W) relative to the 385.0 W all-CEC solar panel median.
What Dataset Percentiles Define CSI Solar Co Ltd CS3L-335P?
Dataset percentiles tracking CSI Solar Co Ltd CS3L-335P power output, thermal retention ratio, and aperture efficiency against 21,677 models.
What Do the Dataset Ranks Show for CSI Solar Co Ltd CS3L-335P?
Benchmark highlights for CSI Solar Co Ltd CS3L-335P covering STC output, efficiency, 8 kW footprint, and OCPD breaker size.
335.0 W STC · Higher Than 34.7%
335.0 W STC (-50.0 W vs all-CEC median) vs 278.8 W Multi-c-Si median.
18.72% Aperture Efficiency
Power density 187.2 W/m2 (1.19 percentage points below 19.91% CEC median). PTC/STC ratio: 93.2% (rank #8,924).
13 Panels Max @ -10 C (600 V)
Cold Voc reaches 43.11 V at -10 C (560.4 V string) and 44.17 V at -20 C (13 max).
24 Panels = 8,040 W STC
Occupies 43.0 m2 (462 sq ft) producing 7,490 W PTC; NEC 690.8 OCPD floor is 17.0 A (20 A breaker).
NEC 690.7(A) Cold-Temperature Voc & 690.8 OCPD Formula
Voc_cold = 39.4 * (1 + (-0.269/100) * (-10 - 25)) = 43.11 V | OCPD = 1.56 * 10.9 = 17.0 A
Inputs from CEC Modules.csv for CSI Solar Co Ltd CS3L-335P: Voc=39.4 V, beta_Voc=-0.269%/C, Isc=10.9 A, STC=335.0 W, Area=1.79 m2.
Result: 13 panels max on 600 V (560.4 V); 24 panels for 8 kW (462 sq ft).
What Are the Published CEC Specifications for CSI Solar Co Ltd CS3L-335P?
Official CEC datasheet figures for CSI Solar Co Ltd CS3L-335P (Multi-c-Si) used in utility interconnection and permit reviews.
| Parameter | Measured / Listed Value | Engineering Significance |
|---|---|---|
| Nameplate Power (STC) | 335.0 W | Rated DC output under Standard Test Conditions (1000 W/m2, 25C cell) |
| Real-World Output (PTC) | 312.1 W (93.2% STC) | PVUSA Test Conditions rating used for utility interconnection |
| Open-Circuit Voltage (Voc) | 39.4 V | Primary cold-weather string sizing limit under NEC 690.7 |
| Short-Circuit Current (Isc) | 10.9 A | Determines 156% (1.25x1.25) OCPD fuse/breaker sizing under NEC 690.8 |
| Max Power Voltage / Current | 32.4 V / 10.34 A | Inverter MPPT operating window alignment |
| Voc Temp Coefficient (beta_Voc) | -0.269 %/C | Negative slope governing voltage rise below 25C |
| Module Efficiency & Area | 18.72% (1.79 m2) | Array roof footprint density |
| Cell Count & Technology | 60 cells (Multi-c-Si) | Monofacial backsheet |
How Many CSI Solar Co Ltd CS3L-335P Panels Build a 6 kW, 8 kW, or 10 kW Array?
How many CSI Solar Co Ltd CS3L-335P modules and square feet are required for 6 kW, 8 kW, and 10 kW home solar arrays.
| Target Array | Panels | Actual DC | Roof Area | US Avg ($/yr) | CA High ($/yr) |
|---|---|---|---|---|---|
| 6 kW Class | 18 | 6.03 kW | 347 sq ft | $1,509 | $2,552 |
| 8 kW Class | 24 | 8.04 kW | 462 sq ft | $2,012 | $3,403 |
| 10 kW Class | 30 | 10.05 kW | 578 sq ft | $2,515 | $4,253 |
Which Sibling Wattage & Trim Variants Belong to This CSI Solar Co Ltd Series?
Consolidated CSI Solar Co Ltd wattage variants sharing the CSI Solar Co Ltd CS3L-335P mechanical and cell layout.
| Model Variant | STC (W) | PTC (W) | Voc (V) | Vmp (V) | Eff (%) |
|---|---|---|---|---|---|
| CSI Solar Co Ltd CS3L-325P | 325.0 W | 302.5 W | 39.0 V | 32.0 V | 18.16% |
| CSI Solar Co Ltd CS3L-330P | 330.0 W | 307.3 W | 39.2 V | 32.2 V | 18.44% |
| CSI Solar Co Ltd CS3L-335P | 335.0 W | 312.1 W | 39.4 V | 32.4 V | 18.72% |
| CSI Solar Co Ltd CS3L-340P | 340.0 W | 316.9 W | 39.6 V | 32.6 V | 18.99% |
| CSI Solar Co Ltd CS3L-345P | 345.0 W | 321.6 W | 39.8 V | 32.8 V | 19.27% |
How Many CSI Solar Co Ltd CS3L-335P Modules Fit in a Cold-Weather String?
NEC 690.7(A) winter string table preventing overvoltage trips on CSI Solar Co Ltd CS3L-335P (43.11 V at 14 F).
| Ambient Min Temp | Cold Voc / Panel | Max Panels (600 V) | 600 V String Voc | Max Panels (1000 V) |
|---|---|---|---|---|
| -20 C (-4 F) | 44.17 V | 13 panels | 574.2 V | 22 panels |
| -10 C (14 F) | 43.11 V | 13 panels | 560.4 V | 23 panels |
| 0 C (32 F) | 42.05 V | 14 panels | 588.7 V | 23 panels |
| 25 C (77 F STC) | 39.4 V | 15 panels | 591.0 V | 25 panels |
Which Cross-Brand Solar Modules Compare Closest to CSI Solar Co Ltd CS3L-335P?
Competing CEC solar panels closest to CSI Solar Co Ltd CS3L-335P in nameplate wattage and Voc, starting with Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}.
| Alternative Module | STC (W) | Delta vs This | Voc (V) | Eff (%) | PTC/STC |
|---|---|---|---|---|---|
| Aptos Solar Technology LLC DNA-120-MF23-335W {Blk} Aptos Solar Technology LLC |
335.0 W | Tie (0 W) | 40.44 V | 19.85% | 90.8% |
| Aptos Solar Technology LLC DNA-120-MF23-335W {Wht} Aptos Solar Technology LLC |
335.0 W | Tie (0 W) | 40.44 V | 20.55% | 93.6% |
| AXITEC AC-335MH/120S AXITEC |
335.0 W | Tie (0 W) | 40.44 V | 20.18% | 93.5% |
| AXITEC AC-335MH/120V AXITEC |
335.0 W | Tie (0 W) | 40.44 V | 20.18% | 93.5% |
What Are the Design Limits and Best-Fit Uses for CSI Solar Co Ltd CS3L-335P?
Evaluate CSI Solar Co Ltd CS3L-335P (335.0 W STC, 39.4 V Voc) against your roof geometry, winter climate, and inverter voltage ceiling before finalizing bids.
- Winter overvoltage boundary: at -20 C (-4 F), CSI Solar Co Ltd CS3L-335P reaches 44.17 V per panel—exceeding 13 panels in series voids 600 V inverter warranties.
- Footprint constraint: 24 panels for an 8 kW build require 462 sq ft of unshaded roof plane — useful on tight dormer roofs or battery cabins, though 8 kW requires 24 panels (462 sq ft).
- 2026 tax credit baseline: cash residential installs of CSI Solar Co Ltd CS3L-335P carry 0% federal 25D credit after 2025-12-31, making 18.54 c/kWh+ utility avoidance key.
CSI Solar Co Ltd CS3L-335P 8 kW Residential Fit
Needs 24 modules (462 sq ft) with a 20 A string OCPD, offsetting ~$2,012/yr at US average tariffs.
Cold-Climate String Design (-10 C / -20 C)
Cap 600 V series strings at 13 panels (-10 C) or 13 panels (-20 C), or compare Aptos Solar Technology LLC DNA-120-MF23-335W {Blk}.
Bifacial / High-Heat Roof Check
Monofacial backsheet sealing targets flush dark shingle rooftop mounts. Real-world output tracks 312.1 W PTC.
Which Homeowner Electrical & Solar Questions Come Up Most Often?
Technical answers for CSI Solar Co Ltd CS3L-335P by CSI Solar Co Ltd grounded in CEC test data and NEC 690.7/690.8 limits.
What fuse or breaker size does NEC 690.8 require for CSI Solar Co Ltd CS3L-335P?
Multiplying CSI Solar Co Ltd CS3L-335P's 10.9 A short-circuit current by 1.56 equals 17.0 A minimum ampacity, requiring at least a 20 A overcurrent fuse or breaker.
Can CSI Solar Co Ltd CS3L-335P pair with microinverters instead of a 600 V string inverter?
Yes—if the microinverter DC input ceiling exceeds 43.11 V cold Voc at 14 F and handles 10.9 A Isc; string inverters cap CSI Solar Co Ltd CS3L-335P at 13 panels on 600 V.
Is CSI Solar Co Ltd CS3L-335P eligible for the 30% federal 25D solar credit in 2026?
No. Federal Section 25D expired December 31, 2025 under Public Law 119-21, so 2026 cash installs of CSI Solar Co Ltd CS3L-335P rely on utility bill offset (~$2,012/yr at 8 kW) rather than 25D.
Sources
- CEC Solar Equipment List — PV Modules (NREL SAM Distribution) — California Energy Commission / NREL SAM, 2026-Q4 SAM Develop (retrieved 2026-11-23)
- NFPA 70 National Electrical Code (Section Numbers & Standard Engineering Tables Only) — National Fire Protection Association (NFPA), 2020 / 2023 / 2026 Editions (retrieved 2026-11-23)